Abstract
Primary graft dysfunction (PGD) is a rare complication associated with high mortality after heart transplantation, which may require veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) support. A standardized definition for PGD was developed by the International Society of Heart and Lung Transplantation in 2014. Due to limited reports using this definition, the detailed outcomes after VA-ECMO support remain unclear. Therefore, we retrospectively analyzed our single-center outcomes of PGD following VA-ECMO support. Between September 2014 and August 2018, 160 patients underwent heart transplantation in our single center. Nine PGD patients required VA-ECMO support, with an incidence of 5.6%. Pre-operative recipient/donor demographics, intra-operative variables, timing of VA-ECMO initiation and support duration, graft function recovery during 30 days after heart transplant, VA-ECMO complications, and survival were analyzed. The indication for VA-ECMO support was biventricular failure for all nine patients. Six patients had severe PGD requiring intra-operative VA-ECMO, while two patients had moderate PGD and one patient had mild PGD requiring post-operative VA-ECMO. All cohorts were successfully decannulated in a median of 10 days. Survival to discharge rate was 88.9%. One-year survival rate was 85.7%. Left ventricular ejection fraction recovered to normal within 30 days in all PGD patients. Our study showed VA-ECMO support led to high survival and timely graft function recovery in all cohorts. Further larger research can clarify the detailed effects of VA-ECMO support which may lead to standardized indication of VA-ECMO support for PGD patients.
Similar content being viewed by others
References
Yusen RD, Edwards LB, Kucheryavaya AY, et al. The registry of the international society for heart and lung transplantation: thirty-second official adult lung and heart-lung transplantation report—2015. J Heart Lung Transplant. 2015;34:1264–77.
Christie JD, Edwards LB, Kucheryavaya AY, et al. The registry of the international society for heart and lung transplantation: twenty-seventh official adult lung and heart-lung transplant report—2010. J Heart Lung Transplant. 2010;29:1104–18.
Kobashigawa J, Zuckermann A, Macdonald P, et al. Report from a consensus conference on primary graft dysfunction after cardiac transplantation. J Heart Lung Transplant. 2014;33:327–40.
Russo MJ, Iribarne A, Hong KN, et al. Factors associated with primary graft failure after heart transplantation. Transplantation. 2010;90:444–50.
D’Alessandro C, Golmard JL, Barreda E, et al. Predictive risk factors for primary graft failure requiring temporary extra-corporeal membrane oxygenation support after cardiac transplantation in adults. Eur J Cardiothorac Surg. 2011;40:962–9.
Sy E, Sklar MC, Lequier L, Fan E, Kanji HD. Anticoagulation practices and the prevalence of major bleeding, thromboembolic events, and mortality in venoarterial extracorporeal membrane oxygenation: a systematic review and meta-analysis. J Crit Care. 2017;39:87–96.
Camp PC. Heart transplantation: donor operation for heart and lung transplantation. Op Tech Thorac Cardiovasc Surg. 2010;15:125–37.
Pozzi M, Bottin C, Armoiry X, et al. Extracorporeal life support for primary graft dysfunction after heart transplantation. Interact Cardiovasc Thorac Surg. 2018;27:778–84.
Kirklin JK, Naftel DC, Stevenson LW, et al. INTERMACS database for durable devices for circulatory support: First annual report. J Heart Lung Transplant 2008;27:1065-72.
Marasco SF, Kras A, Schulberg E, Vale M, Lee GA. Impact of warm ischemia time on survival after heart transplantation. Transpl Proc. 2012;44:1385–9.
Yusen RD, Edwards LB, Dipchand AI, et al. the registry of the international society for heart and lung transplantation: thirty-third adult lung and heart-lung transplant report—2016; focus theme: primary diagnostic indications for transplant. J Heart Lung Transplant. 2016;35:1170–84.
Takeda K, Li B, Garan AR, et al. Improved outcomes from extracorporeal membrane oxygenation versus ventricular assist device temporary support of primary graft dysfunction in heart transplant. J Heart Lung Transplant. 2017;36:650–6.
Lima EB, Cunha CR, Barzilai VS, et al. Experience of ECMO in primary graft dysfunction after orthotopic heart transplantation. Arq Bras Cardiol. 2015;105:285–91.
Hulman M, Artemiou P, Ondrusek M, et al. Short-term mechanical circulatory support for severe primary graft dysfunction following orthotopic heart transplant. Interact Cardiovasc Thorac Surg. 2018;27:229–33.
Loforte A, Murana G, Cefarelli M, et al. Role of intra-aortic balloon pump and extracorporeal membrane oxygenation in early graft failure after cardiac transplantation: early graft failure and mechanical circulatory support. Artif Organs. 2016;40:136–45.
Squiers JJ, Saracino G, Chamogeorgakis T, et al. Application of the international society for heart and lung transplantation (ISHLT) criteria for primary graft dysfunction after cardiac transplantation: outcomes from a high-volume centre. Eur J Cardiothorac Surg. 2016;51:263–70.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of interest
No funding was provided for this study. No authors have any conflicts of interest or any financial relationships with commercial entities to disclose.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Kawabori, M., Mastroianni, M.A., Zhan, Y. et al. A case series: the outcomes, support duration, and graft function recovery after VA-ECMO use in primary graft dysfunction after heart transplantation. J Artif Organs 23, 140–146 (2020). https://doi.org/10.1007/s10047-019-01146-y