Abstract
Radio-frequency receiver phased-array coils in magnetic resonance imaging systems are used to pick up the signals emitted by the nuclei with high signal-to-noise ratio and a large region of sensitivity. Since the quality of obtained images strongly depends upon the correct choice of the coil geometry and position, array coils have to be designed by minimizing the mutual interaction among nearby coil elements and this is generally achieved by overlapping such adjacent elements. In this paper, we describe the use of a numerical solver based on finite-difference time-domain method to determine the optimal overlap distance, which guarantees the maximum decoupling level between the coil loops, for array coils constituted by various geometry elements. A novel array coil was designed, constituted by a couple of elliptical geometry elements in “folding” version around the animals’ spine curvature, for small animals’ imaging applications.
Similar content being viewed by others
References
R.S. Khandpur, Handbook of Biomedical Instrumentation (MacGraw-Hill, New York, 1991)
P.B. Roemer, W.A. Edelstein, C.E. Hayes, S.P. Souza, O.M. Mueller, Magn. Reson. Med. 16, 192–225 (1990)
B.K. Li, F. Liu, S. Crozier, Magn. Reson. Med. 53, 1251–1257 (2005)
R.G. Pinkerton, E.A. Barberi, R.S. Menon, J. Magn. Reson. 171, 151–156 (2004)
G. Giovannetti, V. Hartwig, V. Viti, P. Zadaricchio, L. Meini, L. Landini, A. Benassi, Concepts Magn. Reson. Part B Magn. Reson. Eng. 33B, 32–38 (2008)
K.S. Yee, IEEE Trans. Antenna Propag. AP-14, 302–307 (1966)
G. Giovannetti, V. Viti, V. Positano, M.F. Santarelli, L. Landini, A. Benassi, Concepts Magn. Reson. Part B Magn. Reson. Eng. 31B, 140–146 (2007)
F. Seifert, G. Wubbeler, S. Junge, B. Ittermann, H. Rinneberg, J. Magn. Reson. Imaging 26, 1315–1321 (2007)
W. Yu, R. Mittra, CFDTD—Conformal Finite-Difference Time-Domain Maxwell’s Equations Solver—Software and user’s guide (Artech House Publisher, London, 2004)
W. Bandurski, IEEE Trans. Circuits Syst. I Fundam. Theory Appl. 47(8), 1224–1234 (2000)
American Society for Testing and Material ASTM, Designation: F2182–02a. Standard Test Method for Measurement of Radio Frequency Induced Heating near Passive Implants during Magnetic Resonance Imaging (ASTM, West Conshohocken, 2004)
N. Martini, M.F. Santarelli, G. Giovannetti, M. Milanesi, D. De Marchi, V. Positano, L. Landini, NMR Biomed. 23, 66–73 (2010)
N. De Zanche, J.A. Massner, C. Leussler, K.P. Pruessmann, NMR Biomed. 21(6), 644–654 (2008)
J.R. Porter, S.M. Wright, A. Reykowski, Magn. Reson. Med. 40, 272–279 (1998)
F. Wiesinger, P.F. Van de Moortele, G. Adriany, N. De Zanche, K. Ugurbil, K.P. Pruessmann, NMR Biomed. 19, 368–378 (2006)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Giovannetti, G., Frijia, F., Hartwig, V. et al. A Novel Magnetic Resonance Phased-Array Coil Designed with FDTD Algorithm. Appl Magn Reson 39, 225–231 (2010). https://doi.org/10.1007/s00723-010-0150-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00723-010-0150-z