Abstract
BioGlue® is an inert, bioadhesive surgical substance commonly used in spinal surgery to aid dural closure. The authors describe two cases in which the use of BioGlue® caused a local reaction culminating in the formation of a granuloma that caused cord compression several years after surgery in one case in which a second operation was required to relieve cord compression and remove the foreign material. In the other case spontaneous resolution occurred. To our knowledge these are the first reports of delayed spinal cord compression secondary to BioGlue®-induced granuloma. We recommend judicious use of this substance.
Similar content being viewed by others
References
Miscusi M (2008) BioGlue® surgical adhesive as a dural sealant in neurosurgery clinical needs and surgical technique. http://www.cryolife.com/products/bioglue-surgical-adhesive/. Last accessed 15 June 2017
Kumar A, Maartens NF, Kaye AH (2003) Reconstruction of the sellar floor using bioglue following transsphenoidal procedures. J Clin Neurosci: Off J Neurosurg Soc Australas 10:92–95
Kumar A, Maartens NF, Kaye AH (2003) Evaluation of the use of BioGlue in neurosurgical procedures. J Clin Neurosci: Off J Neurosurg Soc Australas 10:661–664
Abuzayed B, Erman H, Inan M, Aydlin S, Sanus G (2010) Acute mass formation of BioGlue after spinal dural repair: a glue-oma case report. Neurosurg Q 20:253–255
Lauvin MA, Zemmoura I, Cazals X, Cottier JP (2015) Delayed cauda equina compression after spinal dura repair with BioGlue: magnetic resonance imaging and computed tomography aspects of two cases of “glue-oma”. Spine J: Off J North Am Spine Soc 15:e5–e8
Yuen T, Kaye AH (2005) Persistence of bioglue in spinal dural repair. J Clin Neurosci: Off J Neurosurg Soc Australas 12:100–101
Stylli SS, Kumar A, Gonzales M, Kaye AH (2004) The biocompatibility of BioGlue with the cerebral cortex: a pilot study. J Clin Neurosci: Off J Neurosurg Soc Australas 11:631–635
Woo EJ (2012) Dural repairs with spinal sealants. Spine J: Off J North Am Spine Soc 12:279 author reply 280-271
Miscusi M, Polli FM, Forcato S, Coman MA, Ricciardi L, Ramieri A, Raco A (2014) The use of surgical sealants in the repair of Dural tears during non-instrumented spinal surgery. Eur Spine J: Off Publ Eur Spine Soc Eur Spinal Deformity Soc Eur Section Cervical Spine Res Soc 23:1761–1766
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflicts of interest.
Human and animal rights and informed consent.
Patient consent
The patient has consented to submission of this case report to the journal.