Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study

  • Original Article
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

In total hip arthroplasty of the acetabular roof fixed by press-fit without screw fixation, there is little possibility for loosening to occur, because it is difficult for wear debris to enter between the cup and the acetabular roof, as screw holes are not present. However, stability is provided only by contact. In the case of acetabular dysplasia, it is not well understood whether sufficient initial fixation power is provided. We performed a torsion test and a lever-out test. In the torsion test, in the case of a normal hip joint, as the cup grew bigger, the fixation power tended to increase in strength. In the acetabular dysplasia model, with cups of each size, as the protrusion angle increased, the fixation power of the cup tended to become weak. When the protrusion angle approaches 15 degrees, we must use a cup that is 4 mm larger than the original cup to achieve the same initial fixation power. Furthermore, when the protrusion angle is 15 degrees in cups that are over 48 mm in size, we obtain fixation power that is theoretically adequate, but when small cups, for example, 46 mm in size are set with protrusion, the initial fixation power decreases significantly, and we cannot obtain a fixation power that is theoretically adequate.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. J Arthroplasty 9(3):235–242

    Article  PubMed  CAS  Google Scholar 

  2. Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty: Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74:849–863

    PubMed  CAS  Google Scholar 

  3. Schmalzried TP, Callaghan JJ (1999) Current concept review-wear in total hip and knee replacements. J Bone Joint Surg Am 81:115–136

    PubMed  CAS  Google Scholar 

  4. Pagnao MW, Hanssen AD, Lewallen G (1996) The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty. J Bone Joint Surg Am 78(7):1004–1014

    Google Scholar 

  5. Iwase H, Kaneko K, Atsuhiko M (2002) Biomechanical behavior of Hansson Hook Pin System for Femoral Neck Fracture. An Experimental study using a resin bone model (in Japanese). J Jpn Soc Clin Biomech 23:283–289

    Google Scholar 

  6. Haddad RJ, Cook SD, Brinker MR (1990) A comparison of three varieties of noncemented porous-coated hip replacement. J Bone Joint Surg Br 72:2–8

    PubMed  CAS  Google Scholar 

  7. Foktor SK, Repše-Fokter A, Takač I (2009) Femoral neuropathy secondary to total hip arthroplasty wear debris. Clin Orthop Relat Res 467:3032–3035

    Article  Google Scholar 

  8. Sasada T, Tsukamoto Y, Mabuchi K (1988) Biotribology. Sangyotsho, Tokyo (in Japanese)

    Google Scholar 

  9. Bergmann G, Graichen F, Rohlmann A (1993) Hip joint loading during walking and running, measured in two patients. J Biomech 26(8):969–990

    Article  PubMed  CAS  Google Scholar 

  10. Sugano N, Nishii T, Nakata K (1995) Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. J Bone Joint Surg Br 77:548–556

    PubMed  CAS  Google Scholar 

  11. Takao M, Sugano N, Nishii T (2005) Analysis of the bone coverage that is necessary for the press-fit fixation of the cement less cup using 3D-CT (in Japanese). Jpn Artif Jaw Official J Scientif Soc 35:265–266

Download references

Conflict of interest

No funds were received in support of this study. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Akio Kanda.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kanda, A., Kaneko, K., Obayashi, O. et al. Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study. Eur J Orthop Surg Traumatol 23, 417–424 (2013). https://doi.org/10.1007/s00590-012-0985-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-012-0985-0

Keywords

Navigation