Abstract
Purpose
Spinal angiography is the gold standard for evaluation or diagnosis of spinal arteriovenous malformations (AVMs). However, some feeding arteries might be overlooked when multiple feeders exist. This study aimed to retrospectively review cases of spinal intra-dural AVMs, which were identified by three-dimensional digital subtraction angiography (3D-DSA), and attempted to estimate the number of feeding arteries.
Methods
We retrospectively reviewed patients with spinal intra-dural AVMs who underwent 3D-DSA at Hokkaido University Hospital from January 2005 to December 2016. We selected 9 patients in whom we could obtain data of multi-planar reconstruction of 3D-DSA. We measured the computed tomography (CT) values of feeding arteries and draining veins. The CT values represented the averages of maximum CT values of 5 continuous axial slices. The ratio of the CT value of feeders to that of drainers (F/D ratio) was calculated. The correlation between the F/D ratio and the number of feeders was examined with Pearson’s correlation coefficient.
Results
The average number of feeders was 2.3 (1–4), and the number of feeders was significantly positively correlated with the F/D ratio (r = 0.855, P = .003).
Conclusions
We conclude that the number of feeding arteries of spinal intra-dural AVMs can be estimated by using the F/D ratio obtained from 3D-DSA.
Graphical abstract
These slides can be retrieved under Electronic Supplementary Material.
Similar content being viewed by others
References
Singh B, Behari S, Jaiswal AK, Sahu RN, Mehrotra A, Mohan BM, Phadke RV (2016) Spinal arteriovenous malformations: is surgery indicated? Asian J Neurosurg 11:134–142
Prestigiacomo CJ, Niimi Y, Setton A, Berenstein A (2003) Three-dimensional rotational spinal angiography in the evaluation and treatment of vascular malformations. AJNR Am J Neuroradiol 24:1429–1435
Schueler BA, Kallmes DF, Cloft HJ (2005) 3D cerebral angiography: radiation dose comparison with digital subtraction angiography. AJNR Am J Neuroradiol 26:1898–1901
Tsapaki V, Vano E, Mavrikou I, Nueofotistou V, Gallego JJ, Fernandez JM, Santos E, Mendez J (2008) Comparison of patient dose in two-dimensional carotid arteriography and three-dimensional rotational angiography. Cardiovasc Intervent Radiol 31:477–482
Tonkopi E, Al-Habsi AH, Shankar JJ (2015) Radiation dose from 3D rotational vs. conventional 2D digital subtraction angiography in intracranial aneurysm coiling. Can J Neurol Sci 42:176–180
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
None of the authors has any potential conflict of interest.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Takamiya, S., Osanai, T., Seki, T. et al. Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography. Eur Spine J 28, 842–848 (2019). https://doi.org/10.1007/s00586-018-5852-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00586-018-5852-1