Introduction

Spinopelvic rigid fixation is often necessary for the treatment of complex spinal pathologies [1]. The options described in the literature refer to the Galveston technique, developed by Allen BL, Jr., and Ferguson RL, which involves the longitudinal insertion of a bar between the two cortices of the iliac bone, or to more modern techniques, such as the use of the iliac screw (IS) and the S2-alar-iliac screw (S2AI) [2,3,4].

Lumbosacral arthrodesis may present mechanical complications that can lead to insufficient or decreased bone consolidation. The use of screws in the iliac bone reduces the incidence of these complications compared with the Galveston technique. However, the use of iliac screws may also present problems, the most common of which are screw prominence and surgical wound infection [5,6,7]. The S2AI fixation technique, originally described by Kebaish and Sponseller, reduces the incidence of these problems due to minimal dissection of soft tissues and an insertion point that is far from the skin, which facilitates the construction of the system since the entry point is aligned with the lumbar and S1 pedicular screws [8, 9].

Both the IS and the S2AI provide mechanical stability for the fixation of lumbosacral spine pathologies, which has led to a significant increase in the use of these techniques in the routine practice of spine surgeons. However, studies on the ideal technical positioning of both techniques are limited [10,11,12]. In addition, no reports have categorically determined the best positioning of the implant or performed a comparison between these techniques [1,2,3].

The present study aims to analyze, describe and compare the insertion and positioning parameters of the S2AI and IS techniques in adult patients without spinal deformities using computed tomography (CT).

Methods

The present study comprises a retrospective analysis of lumbosacral CT images, selected continuously in 2016, from 25 patients who underwent elective procedures at a university hospital to investigate abdominal–pelvic pathologies (nephrolithiasis and diverticular disease). CT images and measurements were collected and analyzed using ISite® Enterprise software (Philips, Amsterdam, The Netherlands). Thin-section images with bone window were used for the measurements.

Inclusion criteria are lumbosacral CT images containing axial, sagittal and coronal sections with the possibility of reconstruction in three dimensions (3D); age between 18 and 65 years; and absence of bone fracture or tumor in the lumbosacral spine. Exclusion criteria are inappropriate images; age extremes; incomplete records; skeletally immature patients; and vertebrae with congenital bone malformation or fusion defects.

Data were stored in an Excel® for Mac spreadsheet (Microsoft Corporation, Redmond, Wash.). After input conferencing, the data were imported into SPSS® 23 for Mac (IBM, Armonk, New York) for statistical analysis. Continuous data were described by the mean and its respective standard deviation (SD) and 95% confidence interval (95% CI), and categorical data were described by the absolute frequency and the respective categorical proportion. Inferential statistics were performed to compare between sides and between different locations relative to the tomography measurements. The data were tested for adherence to a normal distribution, and since no normal distribution was observed, a nonparametric paired comparison test, the Mann–Whitney–Shapiro–Wilk test, was performed. Intraclass correlation was performed to assess data reliability. A type I error of up to 5% was accepted as a statistically significant difference. Statistical analyses were performed by an independent statistician blinded to the data.

Methodology of data analysis

The measurements were obtained independently by four examiners (two orthopedic residents and two spine surgery fellows) with various levels of experience. The examiners were trained to perform measurements prior to the study, and ten cases were selected solely for training purposes. These cases were not included in the final sample. The same training set was used for all measurement evaluations, and the acceptable threshold variation was 2°–3° or 2–3 mm. The measures were standardized as follows: age was measured in years; sex as male or female; thickness, length and width were measured in millimeters; and angle was measured in degrees.

Standardization of IS measurements:

  • Length: measured through the insertion point of the IS (posterior–superior iliac crest) to the anterior–inferior iliac crest;

  • Sagittal angle: tilt angle of the IS in the sagittal section of CT;

  • Axial angle: angle of inclination of the IS in the axial section of CT;

  • Maximum thickness: the greatest thickness between the external cortices of the iliac crest;

  • Minimum thickness: the smallest thickness between the external cortices of the iliac crest in its isthmic region; and

  • Skin distance: the distance between the insertion point of the IS and the skin.

Standardization of S2AI measurements:

  • Length: perpendicular distance between the insertion point of the S2AI (between the foramen of S1 and S2, 2 mm lateral to the paramedian sacral crest up to the anterior–inferior iliac crest);

  • Sagittal angle: tilt angle of the S2AI in the sagittal section of CT;

  • Axial angle: angle of the inclination of the S2AI in the axial section of CT;

  • Maximum thickness: the greatest thickness between the external cortices of the iliac crest;

  • Minimum thickness: the smallest thickness between the external cortices of the iliac crest in its isthmic region; and

  • Skin distance: perpendicular distance between the insertion point of the S2AI and the skin.

Examples of measurements are shown in Figs. 1, 2 and 3.

Fig. 1
figure 1

Example of the entry points for the S2-alar-iliac screw (shown by the red cross) and the iliac screw (shown by the white cross)

Fig. 2
figure 2

Example of the S2AI screw length (between the two white crosses)

Fig. 3
figure 3

Example of the iliac screw length (between the two white crosses)

Results

In this study, 25 pelvic CT images were analyzed, including 12 from males and 13 from females. The mean age was 48.7 years (± 11.7 SD). Reliability analysis indicated that screw length and axial angle were highly reliable.

The mean length of the IS was 141.53 mm (± 8.40 SD). The mean length of the S2AI was 133.67 mm (± 9.89 SD). The mean of the maximum bone thickness of the IS was 20.72 mm (± 2.54 SD), and that of the S2AI was 23.24 mm (± 2.27 SD). The mean of the minimum bone thickness of the IS was 15.94 mm (± 2.34 SD), and that of the S2AI was 17.94 mm (± 2.23 SD).

The mean axial angle at the point of entry of the IS was 22.56° (± 2.08 SD) and that of the S2AI was 33.91° (± 2.20 SD). The mean sagittal angle of the IS entry point was 26.68° (± 2.87 SD), and that of the S2AI was 29.92° (± 2.33 DP). The mean distance from the skin to the IS entry point was 32.46 mm (± 15.02 SD), and the mean distance from the skin to the S2AI entry point was 52.87 mm (± 18.34 SD).

Statistically significant differences were obtained for all variables analyzed, as shown in Table 1.

Table 1 Mann–Whitney–Shapiro–Wilk test

The reliability of the examiners’ measurements is summarized in Tables 2 and 3.

Table 2 Intraclass correlation coefficient—overall
Table 3 Intraclass correlation coefficient—comparative

Discussion

The present study demonstrated by pelvic CT that the entry point angles, skin distances, thicknesses and lengths differed for the placement of the IS and the S2AI in adult patients. Regarding the screw trajectory, that of the IS was 7.8 mm longer than that of the S2AI on average, and the greatest bone thickness of the iliac crest was 2.4 mm larger for the S2AI than for the IS. This study also showed that the S2AI sat 20.5 mm deeper than the IS. These data (length, thickness and skin distance) showed statistically significant differences between the two screw trajectories.

Chang et al. [13] reported results similar to those described above in 20 adolescents aged 12–18 years in a population in the USA. The mean angulation values of the axial and sagittal S2AI in that study were 39° and 38°, respectively. In the present study, the angulation values were 33.9° and 29.9°. Regarding the IS in the same study, the mean axial and sagittal angulation values were 21° and 39°, versus 22° and 27° in the present study [13].

According to the literature, the angulation described for the screw trajectory varies considerably and may present a difference of up to 15° in the sagittal plane [14]. In Chang’s work, the trajectory of the IS screws was longer than that of the S2AI screws, but the authors noted that although most surgeons select screws with lengths ranging from 50 to 75 mm, the length of the S2AI screw trajectory still exceeds these values. Importantly, the individuals studied in Chang’s work were younger than those selected in the present study, and some individuals with immature skeletons may have been included.

Another important consideration from a surgical and postoperative standpoint is the distance from the screws to the skin. We found distances of 32 mm for the IS screws and 53 mm for the S2AI screws. This detail is important for the care of sick, underweight and bedridden patients, which is the reality for many patients with spinal deformities undergoing scoliosis correction surgery. This difference results in greater soft tissue coverage over the screw head and, consequently, a lower risk of exposure. The work by Chang et al. [13] observed a similar difference to that found in our study. In the Chang study, the difference was on average 15 mm deeper in favor of the S2AI screw.

Despite the concordance among some of the data published in this work with the literature, some numerical differences exist. Such variations in measured values can be explained by the choice of different entry points described in the studies, since even millimeter differences can alter the final measured result [3]. Deviations in lumbopelvic patterns according to race, ethnicity, sex, skeletal maturity and age may explain the differences in the measurements and may lead to changes in the angulation of the insertion of the screws and in their trajectories [15,16,17,18].

Most studies have focused on American populations, though some also describe Chinese, Malay and Indian populations [13, 19, 20]. However, no studies describe these data in Brazilian populations or even in Latin American groups. Such descriptions in different populations are important to improve our understanding of individual spinal anatomy and morphology.

The present study followed a retrospective design, which may lead to bias in the sample selection. Regardless, because objective and numerical parameters were measured, the retrospective nature of the present study is a minor limitation. Another possible criticism is the lack of a comprehensive population with a large age range yet already skeletally mature. Age can ultimately act as a confounding factor, especially if there is potential for bone growth. The mean age in our study was 48.7 years (± 11.7 SD), an age group that is expected to present regular radiological parameters. Another consideration is the data collection by evaluators with differing levels of experience. More senior and experienced evaluators may have greater expertise in performing the measurements, given their increased familiarity with these trajectories. We aimed to control this bias by standardizing the measurements through previous training of all the evaluators as well as the senior researcher in this study. The measurement parameters and technique are reproducible and consistent, as shown by the high intra- and interobserver reliability. More experienced examiners obtained slightly more reliable measurements. The standardization of the measurements was effective and homogeneous. Discrete differences in measurements (2°–3° or 3- to 4-mm differences in the means) are not typically clinically significant and reflect only a numerical and merely statistical difference. Among the overall measurements, the length of the IS, axial angle and skin distance exhibited a high degree of reliability (Tables 2, 3).

No significant differences were observed with respect to sex or laterality. Therefore, for greater representability, the right and left laterality data were analyzed as a single group.

Although that was not the focus of this present study, another important aspect regarding the employment of the S2AI technique is the possible modification in the relations of the spinopelvic measures caused by the implant position in the lumbopelvic region. It is said that pelvic incidence is a constant morphological parameter after skeletal maturity; however, several recent studies have questioned these data [21, 22]. This fact deserves future research, including 3D analysis.

To the best of our knowledge, this work represents the first study to perform a comparative and integrated analysis of different parameters of the insertion trajectory of IS and S2AI screws in an adult population with the aid of CT for models with 3D reconstruction. These findings are fundamental and timely since the use of spinopelvic fixation is becoming increasingly common. Studies with larger or multicentric population samples may expand and consolidate the information collected in the present study, including clinical trials.

Conclusion

The trajectory of S2AI screws studied via CT in an adult population was greater in terms of thickness and deeper relative to the skin compared with IS screws. The S2AI technique, when used in adults, may present desirable clinical advantages related to the diameter of the chosen screws and reduced protrusion.