Abstract
Package is one of the key technologies for MEMS accelerometers. This paper investigated the influence of package on performances of custom-designed MEMS piezoresistive accelerometer. Based on the designed package process, the effect of die adhesive and potting materials on the sensor sensitivity and residual stress were studied by theory analysis and experimental test. The results showed that: with more quantity of die adhesive when the thickness was fixed, the sensitivity of MEMS piezoresistive accelerometer was much smaller; in addition, with thicker die adhesive, the accelerometer had much bigger sensitivity and much smaller residual stress increment after the die attach process. Meanwhile, the sensitivity was proportional to the density of potting material, and it varied with the elastic modulus.
Similar content being viewed by others
References
Atwell AR, Okojie RS, Kornegay KT (2003) Simulation, fabrication and testing of bulk micromachined 6H-SiC high-g piezoresistive accelerometers. Sens Actuators A 104:11–18
Campabadal F, Llu′ıs Carreras J, Cabruja E (2006) Flip-chip packaging of piezoresistive pressure sensors. Sens Actuators A 132:415–419
Chen QQ, Xuan FZ, Tu ST (2009) Modeling of creep deformation and its effect on stress distribution in multilayer systems under residual stress and external bending. Thin Solid Films 517:2924–2929
Davies BR, Baker CC, Montague S (1997) High-G MEMS integrated accelerometer. Pro SPIE 3046:52–62
Ghisi A, Fachin F, Mariani S (2009) Multi-scale analysis of polysilicon MEMS sensors subject to accidental drops: effect of packaging. Microelectron Reliab 49:340–349
Gradolpha C, Friedberger A, Mllera G (2009) Impact of high-g and high vibration environments on piezoresistive pressure sensor performance. Sens Actuators A 150:69–77
Guo T, Li P, Xu Y (2011) Study on the package of MEMS high-g acceleration sensor. Adv Mater Res 211–212(pt.2):973–977
He X, Oyadiji SO (2001) Influence of adhesive characteristics on the transverse free vibration of single lap-jointed cantilever beams. J Mater Process Technol 119:366–373
Hsueh CH (2002) Thermal stresses in elastic multilayer systems. Thin Solid Films 418:182–188
Huang WD, Cai X, Xu B (2003) Packaging effects on the performances of MEMS for high-G accelerometer with double cantilevers. Sens Actuators A 1(102):268–278
Huang S, Li X, Song Z et al (2005) A high-performance micromachined piezoresistive accelerometer with axially stressed tiny beams. J Micromech Microeng 15(5):993
Jiang YQ, Du MH, Luo L (2004) Effect of potting on the packaging of high-g MEMS accelerometer. J Mech Strength 26:149–153
Kal S, Das S, Maurya DK (2006) CMOS compatible bulk micromachined silicon piezoresistive accelerometer with low off-axis sensitivity. Microelectron J 1(37):22–30
Kniffin ML (1996) Packaging for Silicon Micromachined Accelerometer. Int J Microcircuits Electron Packag 19(1):75–86
Kuells R (2012) Novel piezoresistive high-g accelerometer geometry with very high sensitivity-bandwidth product. Sens Actuators A 182:41–48
Kuells R, Nau S, Salk M (2012) Novel piezoresistive high-g accelerometer geometry with very high sensitivity-bandwidth product. Sens Actuators A: Phys 182:42–49
Lawes RA (2007) Manufacturing costs for Microsystems/MEMS using high aspect ratio micro-fabrication techniques. Microsyst Technol 13:85–95
Li Q, Goosen JFL, Beek JTM (2008) Failure analysis of a thin-film nitride MEMS package. Microelectron Reliab 7(48):1557–1561
Majcherek S, Leneke T, Hirsch S (2009) A silicon test chip for the thermomechanical analysis of MEMS packaging. Microsyst Technol 15:191–200
Ni ZH (1989) Vibration mechanics. Xi’an JiaoTong University Press, Xi’an
Peng CT, Lin JC, Lin CT (2005) Performance and package effect of a novel piezoresistive pressure sensor fabricated by front-side etching technology. Sens Actuators A 119:28–37
Shi YB, Liu J, Qi XJ (2008) Fabrication and measurement of high-g MEMS accelerometer. Chin J Sci Instrum 7(29):1345–1349
Song J, Huang QA, Li M (2009) Influence of environmental temperature on the dynamic properties of a die attached MEMS device. Microsyst Technol 6(15):925–932
Spearing SM (2000) Materials issues in micro-electro-mechanical system (MEMS). Acta Mater 48:179–196
Tanner DM (2009) MEMS reliability: where are we now. Microeletron Reliab 49:937–940
Tanner DM, Walraven JA, Helgesen K, Irwin LW, Brown F, Smith NF, Masters N (2000) MEMS reliability in shock environments. In: IEEE international reliability physics symposium, April 10–13. San Jose, CA, pp 129–138
Tao G, Yan X, Ping L (2011) Study on encapsulation and SMT technology for MEMS high-g acceleration sensors. Control Instrum Chem Ind 9(38):1133–1154
Teixeira V (2001) Numerical analysis of the influence of coating porosity and substrate elastic properties on the residual stresses in high temperature graded coatings. Surf Coat Technol 146:79–84
Walwakar SS, Cho J (2006) Evaluation of die stress in MEMS packaging: experimental and theoretical approaches. IEEE Trans Compon Packag Technol 29:735–742
Yang ZX, Huang Y, Li XX (2009) Investigation and simulation on the dynamic shock response performance of packaged high-g MEMS accelerometer versus the impurity concentration of the piezoresistor. Microelectron Reliab 5(49):510–516
Acknowledgments
This work was supported by the National Defense Preliminary Research Project.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, P., Gao, S., Liu, H. et al. Effects of package on the performance of MEMS piezoresistive accelerometers. Microsyst Technol 19, 1137–1144 (2013). https://doi.org/10.1007/s00542-012-1711-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-012-1711-x