Skip to main content
Log in

GlideScope videolaryngoscope reduces the incidence of erroneous esophageal intubation by novice laryngoscopists

  • Short Communication
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

The purpose of this study was to evaluate the performance of the GlideScope videolaryngoscope for tracheal intubation by novice laryngoscopists compared with that of the Macintosh laryngoscope. Under supervision by staff anesthetists, non-anesthesia residents performed tracheal intubation using either the GlideScope videolaryngoscope (n = 100) or Macintosh laryngoscope (n = 100). The time required for airway instrumentation, the number of attempts required until successful intubation, and erroneous esophageal intubation were investigated. There were no significant differences in the time needed to secure the airway between the GlideScope videolaryngoscope and the Macintosh laryngoscope. Fewer attempts until successful intubation were made with the GlideScope videolaryngoscope than with the Macintosh laryngoscope (p < 0.05). Erroneous esophageal intubation with the GlideScope videolaryngoscope was less frequent than with the Macintosh laryngoscope (p < 0.05). Compared to the Macintosh laryngoscope, the GlideScope videolaryngoscope reduces the incidence of erroneous esophageal intubation by less experienced laryngoscopists.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1

References

  1. Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth. 2005;52:191–8.

    Article  PubMed  Google Scholar 

  2. Nouruzi-Sedeh P, Schumann M, Groeben H. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology. 2009;110:32–7.

    Article  PubMed  Google Scholar 

  3. You JS, Park S, Chung SP, Park YS, Park JW. The usefulness of the GlideScope video laryngoscope in the education of conventional tracheal intubation for the novice. Emerg Med J. 2009;26:109–11.

    Article  CAS  PubMed  Google Scholar 

  4. Lim Y, Lim TJ, Liu EH. Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways. Can J Anaesth. 2004;51:641–2.

    Article  PubMed  Google Scholar 

  5. Doyle DJ. GlideScope-assisted fiberoptic intubation: a new airway teaching method. Anesthesiology. 2004;101:1252.

    Article  PubMed  Google Scholar 

  6. Hirabayashi Y, Seo N. Tracheal intubation by non-anaesthetist physicians using the Airway Scope. Emerg Med J. 2007;24:572–3.

    Article  PubMed  Google Scholar 

  7. Hirabayashi Y, Seo N. Airtraq optical laryngoscope: tracheal intubation by novice laryngoscopists. Emerg Med J. 2009;26:112–3.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

Support for this study was provided solely by institutional and/or departmental sources.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshihiro Hirabayashi.

About this article

Cite this article

Hirabayashi, Y., Otsuka, Y. & Seo, N. GlideScope videolaryngoscope reduces the incidence of erroneous esophageal intubation by novice laryngoscopists. J Anesth 24, 303–305 (2010). https://doi.org/10.1007/s00540-010-0872-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-010-0872-y

Keywords

Navigation