Abstract
Background and aims
EUS-guided choledochoduodenostomy (EUS-CDS) is an effective option for biliary drainage in malignant biliary obstruction. Lumen apposing metal stents (LAMS) are increasingly been used for EUS-CDS. It is unknown how LAMS compare to tubular self-expandable metal stents (SEMS) for EUS-CDS. Our aim is to compare the clinical outcomes of LAMS versus SEMS for EUS-CDS.
Patients and methods
Single-center retrospective cohort study of consecutive patients with unresectable malignant biliary obstruction who underwent EUS-CDS after failed ERCP for initial biliary drainage between 2011 and 2019. Clinical outcomes were compared between patients who had conventional covered SEMS and LAMS placed for EUS-CDS. Outcome measures included unplanned procedural events, technical success, clinical success, adverse events and reinterventions. Survival was analyzed by the Kaplan–Meier method.
Results
During the study period 57 patients met inclusion criteria (37 LAMS, 20 SEMS). All EUS-CDS were technically successful (LAMS group 95% CI 90.3–100%, SEMS group 95% CI 83.2–100%). There were no differences between groups in unplanned procedural events (4 LAMS deployment issues, 2 mild bleeding in SEMS group; 10 vs 10.8%), clinical success (37/37 [100%] vs 19/20 [95%]), and short-term adverse events (5/37 [13.5%] vs 4/20 [20%], p = 0.71). Complete follow-up data were available in 41 patients for a mean of 376 ± 145 days. Endoscopic reintervention was required for duodenal stent placement (n = 9) or biliary stent dysfunction (n = 4), with no difference between LAMS and SEMS group (6/37 [16.2%] vs 7/20 [35%]). There were no differences in overall survival between both groups.
Conclusions
EUS-guided choledochoduodenostomy after failed ERCP has equally high technical and clinical success rates with either LAMS or SEMS in patients with malignant biliary obstruction. No differences in adverse events, reinterventions and survival were seen with either type of stent. The cost-effectiveness of LAMS vs SEMS for EUS-guided choledochoduodenostomy remains to be proven.
Similar content being viewed by others
References
Chu D, Adler DG (2010) Malignant biliary tract obstruction: evaluation and therapy. JNCCN J Natl Compr Cancer Netw 8(9):1033–1044
Baron TH, Grimm IS, Swanstrom LL (2015) Interventional approaches to gallbladder disease. N Engl J Med 373(4):357–365
Sharaiha RZ, Khan MA, Kamal F, Tyberg A, Tombazzi CR, Ali B, Tombazzi C, Kahaleh M (2017) Efficacy and safety of EUS-guided biliary drainage in comparison with percutaneous biliary drainage when ERCP fails: a systematic review and meta-analysis. Gastrointest Endosc 85(5):904–914. https://doi.org/10.1016/j.gie.2016.12.023
Sharaiha RZ, Kumta NA, Desai AP, DeFilippis EM, Gabr M, Sarkisian AM, Salgado S, Millman J, Benvenuto A, Cohen M, Tyberg A, Gaidhane M, Kahaleh M (2016) Endoscopic ultrasound-guided biliary drainage versus percutaneous transhepatic biliary drainage: predictors of successful outcome in patients who fail endoscopic retrograde cholangiopancreatography. Surg Endosc 30(12):5500–5505
Fabbri C, Luigiano C, Lisotti A, Cennamo V, Virgilio C, Caletti G, Fusaroli P (2014) Endoscopic ultrasound-guided treatments: are we getting evidence based—a systematic review. World J Gastroenterol 20(26):8424–8448
Gupta K, Perez-Miranda M, Kahaleh MK, Artifon ELA, Itoi T, Freeman ML, De-Serna C, Sauer B, Giovannini M (2014) Endoscopic ultrasound-assisted bile duct access and drainage: multicenter, long-term analysis of approach, outcomes, and complications of a technique in evolution. J Clin Gastroenterol 48(1):80–87
Walter D, Will U, Sanchez-Yague A, Brenke D, Brenke D, Hampe J, Wollny H, López-Jamar JME, Jechart G, Vilmann P, Gornals JB, Ullrich S, Fähndrich M, De Tejada AH, Junquera F, Gonzalez-Huix F, Siersema PD, Vleggaar FP (2015) A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a prospective cohort study. Endoscopy 47(1):63–67
Teoh AYB, Binmoeller KF, Lau JYW (2014) Single-step EUS-guided puncture and delivery of a lumen-apposing stent for gallbladder drainage using a novel cautery-tipped stent delivery system. Gastrointest Endosc 80(6):1171
Kunda R, Pérez-Miranda M, Will U, Ullrich S, Brenke D, Dollhopf M, Meier M, Larghi A (2016) EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP. Surg Endosc 30(11):5002–5008
Anderloni A, Fugazza A, Troncone E, Auriemma F, Carrara S, Semeraro R, Maselli R, Di Leo M, D’Amico F, Sethi A, Repici A (2019) Single-stage EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction. Gastrointest Endosc 89(1):69–76. https://doi.org/10.1016/j.gie.2018.08.047
Jacques J, Privat J, Pinard F, Fumex F, Chaput U, Valats JC, Cholet F, Jezequel J, Grandval P, Legros R, Lepetit H, Albouys J, Napoleon B (2020) EUS-guided choledochoduodenostomy by use of electrocautery-enhanced lumen-apposing metal stents: a French multicenter study after implementation of the technique (with video). Gastrointest Endosc. https://doi.org/10.1016/j.gie.2020.01.055
Jacques J, Privat J, Pinard F, Fumex F, Valats JC, Chaoui A, Cholet F, Godard B, Grandval P, Legros R, Kerever S, Napoleon B (2019) Endoscopic ultrasound-guided choledochoduodenostomy with electrocautery-enhanced lumen-apposing stents: a retrospective analysis. Endoscopy 51(6):540–547
El Chafic AH, Shah JN, Hamerski C, Binmoeller KF, Irani S, James TW, Baron TH, Nieto J, Romero RV, Evans JA, Kahaleh M (2019) EUS-guided choledochoduodenostomy for distal malignant biliary obstruction using electrocautery-enhanced lumen-apposing metal stents: first US, multicenter experience. Dig Dis Sci 64(11):3321–3327. https://doi.org/10.1007/s10620-019-05688-2
Tsuchiya T, Teoh AYB, Itoi T, Yamao K, Hara K, Nakai Y, Isayama H, Kitano M (2018) Long-term outcomes of EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction: a prospective multicenter study. Gastrointest Endosc 87(4):1138–1146. https://doi.org/10.1016/j.gie.2017.08.017
Teoh AY, Perez-Miranda M, Kunda R, Lee SS, Irani S, Yeaton P, Sun S, Baron TH, Moon JH, Holt B, Khor CJL, Rerknimitr R, Bapaye A, Chan SM, Choi HJ, James TW, Kongkam P, Lee YN, Parekh P, Ridtitid W, Serna-Higuera C, Tan DMY, Torres-Yuste R (2019) Outcomes of an international multicenter registry on EUS-guided gallbladder drainage in patients at high risk for cholecystectomy. Endosc Int Open 7(8):E964–E973
Cotton PB, Eisen GM, Aabakken L, Baron TH, Hutter MM, Jacobson BC, Mergener K, Nemcek A, Petersen BT, Petrini JL, Pike IM, Rabeneck L, Romagnuolo J, Vargo JJ (2010) A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 71(3):446–454
Mosquera-Klinger G, De-La-Serna-Higuera C, Pérez-Miranda M (2019) Endoscopic sump syndrome secondary to EUS-guided choledochoduodenostomy with a lumen-apposing metal stent. Rev Esp Enfermedades Dig 111(1):74–76
Khashab M, El Zein M, Sharzehi K, Marson F, Haluszka O, Small A, Nakai Y, Park DY, Kunda R, Teoh AY, Peñas I, Perez-Miranda M, Kumbhari V, Van der Merwe S, Artifon EL, Ross AS (2016) EUS-guided biliary drainage or enteroscopy-assisted ERCP in patients with surgical anatomy and biliary obstruction: an international comparative study. Endosc Int Open 4(12):E1322–E1327
Bang JY, Navaneethan U, Hasan M, Hawes R, Varadarajulu S (2018) Stent placement by EUS or ERCP for primary biliary decompression in pancreatic cancer: a randomized trial (with videos). Gastrointest Endosc 88(1):9–17
Paik WH, Lee TH, Park DH, Choi JH, Kim SO, Jang S, Kim DU, Shim JH, Song TJ, Lee SS, Seo DW, Lee SK, Kimet MH (2018) EUS-guided biliary drainage versus ERCP for the primary palliation of malignant biliary obstruction: a multicenter randomized clinical trial. Am J Gastroenterol 113(7):987–997. https://doi.org/10.1038/s41395-018-0122-8
Iwashita T, Doi S, Yasuda I (2014) Endoscopic ultrasound-guided biliary drainage: a review. Clin J Gastroenterol 7(2):94–102
Dhir V, Itoi T, Khashab MA, Park DH, Yuen Bun Teoh A, Attam R, Messallam A, Varadarajulu S, Maydeoet A (2015) Multicenter comparative evaluation of endoscopic placement of expandable metal stents for malignant distal common bile duct obstruction by ERCP or EUS-guided approach. Gastrointest Endosc 81(4):913–923
Artifon ELA, Marson FP, Gaidhane M, Kahaleh M, Otoch JP (2015) Hepaticogastrostomy or choledochoduodenostomy for distal malignant biliary obstruction after failed ERCP: is there any difference? Gastrointest Endosc 81(4):950–959
Poincloux L, Rouquette O, Buc E, Privat J, Pezet D, Dapoigny M, Bommelaer G, Abergelet A (2015) Endoscopic ultrasound-guided biliary drainage after failed ERCP: cumulative experience of 101 procedures at a single center. Endoscopy 47(9):794–801
Cho DH, Lee SS, Oh D, Song TJ, Park DH, Seo DW, Lee SK, Kimet MH (2017) Long-term outcomes of a newly developed hybrid metal stent for EUS-guided biliary drainage (with videos). Gastrointest Endosc 85(5):1067–1075
Park JK, Woo YS, Noh DH, Il YJ, Bae SY, Yun HS, Lee JK, Lee KT, Lee KH (2018) Efficacy of EUS-guided and ERCP-guided biliary drainage for malignant biliary obstruction: prospective randomized controlled study. Gastrointest Endosc 88(2):277–282. https://doi.org/10.1016/j.gie.2018.03.015
Mohan B, Jayaraj M, Asokkumar R, Shakhatreh M, Pahal P, Ponnada S, Navaneethan U, Adler DG (2019) Lumen apposing metal stents in drainage of pancreatic walled-off necrosis, are they any better than plastic stents? A systematic review and meta-analysis of studies published since the revised Atlanta classification of pancreatic fluid collections. Endosc Ultrasound 8(2):82–90
Funding
No financial support was needed to conduct this study.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Disclosures
Dr. Manuel Perez-Miranda is a consultant for Boston Scientific and M.I.Tech and has lectured for Boston Scientific and Olympus. Dra. Marina de Benito Sanz, Dr. Rodrigo Nájera Muñoz, Dr. Carlos de la Serna, Dr. Esteban Fuentes-Valenzuela, Dr. Ignacio Fanjul, Dr. Carlos Chavarría, Dr. Francisco Javier Garcia-Alonso, Dr. Ramón Sanchez-Ocana, Dra. Ana Yaiza Carbajo and Dr. Sergio Bazaga have no potential conflicts of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
de Benito Sanz, M., Nájera-Muñoz, R., de la Serna-Higuera, C. et al. Lumen apposing metal stents versus tubular self-expandable metal stents for endoscopic ultrasound-guided choledochoduodenostomy in malignant biliary obstruction. Surg Endosc 35, 6754–6762 (2021). https://doi.org/10.1007/s00464-020-08179-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-020-08179-y