Skip to main content
Log in

3D image of the middle ear ossicles: three protocols of post-processing based on multislice computed tomography

  • Otology
  • Published:
European Archives of Oto-Rhino-Laryngology Aims and scope Submit manuscript

Abstract

The aim of this study was to examine and assess the comparative values of HRCT-based multiplanar reformation (MPR), volume rendering (VR) and virtual endoscope built on three-dimensional shaded-surface display (SSD-based CTVE) for evaluations of the ossicular chain. The normal pure tone audiograms, type-A tympanogram, and normal HRCT characteristics of 32 human ears of 18 patients were reviewed, whose ossicular chains were reconstructed with the three aforementioned protocols and assessed via the 3-point scoring system. The HRCT-based protocols could demonstrate a 3D image of the ossicular chain, except that of the footplate on the SSD-based CTVE. On the qualitative assessment, the efficacy of the MPR and VR, which were both superior to the SSD-based CTVE (P < 0.05), presented no statistical significance among the major and/or hyperdense structures (P > 0.05). As regards the lateral process of the malleus, VR was found to be significantly superior to the MPR and SSD-based CTVE (P < 0.05), both of which, however, showed no significant comparative differences (P > 0.05). Moreover, the three protocols in terms of efficacy were comparatively different in their representations of the anterior crus and footplates of the stapes, respectively (P < 0.05). On the MPR images, not all the images of the lenticular process were ideal; 20 of 32 cases were detected, but not defined. VR could be the more valuable protocol for the 3D reconstruction of the ossicular chain and ought to be more employed in future, especially in education.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Lane JI, Lindell EP, Witte RJ, DeLone DR, Driscoll CL (2006) Middle and inner ear: improved depiction with multiplanar reconstruction of volumetric CT data. RadioGraphics 26:115–124. doi:10.1148/rg.261055703

    Article  PubMed  Google Scholar 

  2. Chuang MT, Chiang IC, Liu GC, Lin WC (2006) Multidetector row CT demonstration of inner and middle ear structures. Clin Anat 19:337–344. doi:10.1002/ca.20213

    Article  PubMed  Google Scholar 

  3. Morra A, Tirelli G, Rimondini A, Cioffi V, Russolo M, Giacomarra V, Pozzi-Mucelli R (2002) Usefulness of virtual endoscopic three-dimensional reconstructions of the middle ear. Acta Otolaryngol 122:382–385. doi:10.1080/00016480260000058

    Article  PubMed  CAS  Google Scholar 

  4. Klingebiel R, Bauknecht HC, Kaschke O, Werbs M, Freigang B, Behrbohm H, Rogalla P, Lehmann R (2001) Virtual endoscopy of the tympanic cavity based on high-resolution multislice computed tomographic data. Otol Neurotol 22:803–807

    Article  PubMed  CAS  Google Scholar 

  5. Seemann MD, Seemann O, Bonel H, Suckfüll M, Englmeier KH, Naumann A, Allen CM, Reiser MF (1999) Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images. Eur Radiol 9:1851–1858. doi:10.1007/s003300050934

    Article  PubMed  CAS  Google Scholar 

  6. Decraemer WF, Dirckx JJ, Funnell WR (2003) Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4(2):250–263. doi:10.1007/s10162-002-3030-x

    Article  PubMed  CAS  Google Scholar 

  7. Fatterpekar GM, Doshi AH, Dugar M, Delman BN, Naidich TP, Som PM (2006) Role of 3D CT in the evaluation of the temporal bone. Radiographics 26:S117–S132. doi:10.1148/rg.26si065502

    Article  PubMed  Google Scholar 

  8. Himi T, Sakata M, Shintani T, Mitsuzawa H, Kamagata M, Satoh J, Sugimoto H (2000) Middle ear imaging using virtual endoscopy and its application in patients with ossicular anomaly. ORL Otorhinolaryngol Relat Spec 62(6):316–320

    CAS  Google Scholar 

  9. Karhuketo TS, Dastidar PS, Ryymin PS, Laasonen EM, Puhakka HJ (2002) Virtual endoscopy imaging of the middle ear cavity and ossicles. Eur Arch Otorhinolaryngol 259(2):77–83. doi:10.1007/s004050100410

    Article  PubMed  CAS  Google Scholar 

  10. Neri E, Caramella D, Panconi M, Berrettini S, Sellari Franceschini S, Forli F, Barttolozzi C (2001) Virtual endoscopy of the middle ear. Eur Radiol 11(1):41–49. doi:10.1007/s003300000612

    Article  PubMed  CAS  Google Scholar 

  11. Jun BC, Song SW, Cho JE, Park CS, Lee DH, Chang KH, Yeo SW (2005) Three-dimensional reconstruction based on images from spiral high-resolution computed tomography of the temporal bone: anatomy and clinical application. J Laryngol Otol 119(9):693–698

    Article  PubMed  Google Scholar 

  12. Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12(7):1684–1692. doi:10.1007/s00330-002-1313-6

    Article  PubMed  Google Scholar 

  13. Frankenthaler RP, Moharir V, Kikinis R, Van Kipshagen P, Jolesz F, Umans C, Fried MP (1998) Virtual otoscopy. Otolaryngol Clin North Am 31:383–392. doi:10.1016/S0030-6665(05)70056-6

    Article  PubMed  CAS  Google Scholar 

  14. Husstedt HW, Prokop M, Dietrich B, Becker H (2000) Low-dose high-resolution CT of the petrous bone. J Neuroradiol 27(2):87–92. doi:JN-09-2000-27-2-0150-9861-101019-ART82

    PubMed  CAS  Google Scholar 

  15. Calhoun PS, Kuszyk BS, Heath DG, Carley JC, Fishman EK (1999) Three-dimensional volume rendering of spiral CT data: theory and method. Radiographics 19:745–764

    PubMed  CAS  Google Scholar 

  16. Lee DH, Chan S, Salisbury C, Kim N, Salisbury K, Puria S, Blevins NH (2010) Reconstruction and exploration of virtual middle-ear models derived from micro-CT datasets. Hear Res 236(1–2):198–203

    Article  Google Scholar 

  17. Sim JH, Puria S (2008) Soft tissue morphometry of the malleus-incus complex from micro-CT imaging. J Assoc Res Otolaryngol 9(1):5–21

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

We declare that we have no conflict of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yan Sha.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhang, Lc., Sha, Y., Wang, Zm. et al. 3D image of the middle ear ossicles: three protocols of post-processing based on multislice computed tomography. Eur Arch Otorhinolaryngol 268, 677–683 (2011). https://doi.org/10.1007/s00405-010-1441-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00405-010-1441-6

Keywords

Navigation