Abstract
The aim of this study was to examine and assess the comparative values of HRCT-based multiplanar reformation (MPR), volume rendering (VR) and virtual endoscope built on three-dimensional shaded-surface display (SSD-based CTVE) for evaluations of the ossicular chain. The normal pure tone audiograms, type-A tympanogram, and normal HRCT characteristics of 32 human ears of 18 patients were reviewed, whose ossicular chains were reconstructed with the three aforementioned protocols and assessed via the 3-point scoring system. The HRCT-based protocols could demonstrate a 3D image of the ossicular chain, except that of the footplate on the SSD-based CTVE. On the qualitative assessment, the efficacy of the MPR and VR, which were both superior to the SSD-based CTVE (P < 0.05), presented no statistical significance among the major and/or hyperdense structures (P > 0.05). As regards the lateral process of the malleus, VR was found to be significantly superior to the MPR and SSD-based CTVE (P < 0.05), both of which, however, showed no significant comparative differences (P > 0.05). Moreover, the three protocols in terms of efficacy were comparatively different in their representations of the anterior crus and footplates of the stapes, respectively (P < 0.05). On the MPR images, not all the images of the lenticular process were ideal; 20 of 32 cases were detected, but not defined. VR could be the more valuable protocol for the 3D reconstruction of the ossicular chain and ought to be more employed in future, especially in education.
Similar content being viewed by others
References
Lane JI, Lindell EP, Witte RJ, DeLone DR, Driscoll CL (2006) Middle and inner ear: improved depiction with multiplanar reconstruction of volumetric CT data. RadioGraphics 26:115–124. doi:10.1148/rg.261055703
Chuang MT, Chiang IC, Liu GC, Lin WC (2006) Multidetector row CT demonstration of inner and middle ear structures. Clin Anat 19:337–344. doi:10.1002/ca.20213
Morra A, Tirelli G, Rimondini A, Cioffi V, Russolo M, Giacomarra V, Pozzi-Mucelli R (2002) Usefulness of virtual endoscopic three-dimensional reconstructions of the middle ear. Acta Otolaryngol 122:382–385. doi:10.1080/00016480260000058
Klingebiel R, Bauknecht HC, Kaschke O, Werbs M, Freigang B, Behrbohm H, Rogalla P, Lehmann R (2001) Virtual endoscopy of the tympanic cavity based on high-resolution multislice computed tomographic data. Otol Neurotol 22:803–807
Seemann MD, Seemann O, Bonel H, Suckfüll M, Englmeier KH, Naumann A, Allen CM, Reiser MF (1999) Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images. Eur Radiol 9:1851–1858. doi:10.1007/s003300050934
Decraemer WF, Dirckx JJ, Funnell WR (2003) Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4(2):250–263. doi:10.1007/s10162-002-3030-x
Fatterpekar GM, Doshi AH, Dugar M, Delman BN, Naidich TP, Som PM (2006) Role of 3D CT in the evaluation of the temporal bone. Radiographics 26:S117–S132. doi:10.1148/rg.26si065502
Himi T, Sakata M, Shintani T, Mitsuzawa H, Kamagata M, Satoh J, Sugimoto H (2000) Middle ear imaging using virtual endoscopy and its application in patients with ossicular anomaly. ORL Otorhinolaryngol Relat Spec 62(6):316–320
Karhuketo TS, Dastidar PS, Ryymin PS, Laasonen EM, Puhakka HJ (2002) Virtual endoscopy imaging of the middle ear cavity and ossicles. Eur Arch Otorhinolaryngol 259(2):77–83. doi:10.1007/s004050100410
Neri E, Caramella D, Panconi M, Berrettini S, Sellari Franceschini S, Forli F, Barttolozzi C (2001) Virtual endoscopy of the middle ear. Eur Radiol 11(1):41–49. doi:10.1007/s003300000612
Jun BC, Song SW, Cho JE, Park CS, Lee DH, Chang KH, Yeo SW (2005) Three-dimensional reconstruction based on images from spiral high-resolution computed tomography of the temporal bone: anatomy and clinical application. J Laryngol Otol 119(9):693–698
Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12(7):1684–1692. doi:10.1007/s00330-002-1313-6
Frankenthaler RP, Moharir V, Kikinis R, Van Kipshagen P, Jolesz F, Umans C, Fried MP (1998) Virtual otoscopy. Otolaryngol Clin North Am 31:383–392. doi:10.1016/S0030-6665(05)70056-6
Husstedt HW, Prokop M, Dietrich B, Becker H (2000) Low-dose high-resolution CT of the petrous bone. J Neuroradiol 27(2):87–92. doi:JN-09-2000-27-2-0150-9861-101019-ART82
Calhoun PS, Kuszyk BS, Heath DG, Carley JC, Fishman EK (1999) Three-dimensional volume rendering of spiral CT data: theory and method. Radiographics 19:745–764
Lee DH, Chan S, Salisbury C, Kim N, Salisbury K, Puria S, Blevins NH (2010) Reconstruction and exploration of virtual middle-ear models derived from micro-CT datasets. Hear Res 236(1–2):198–203
Sim JH, Puria S (2008) Soft tissue morphometry of the malleus-incus complex from micro-CT imaging. J Assoc Res Otolaryngol 9(1):5–21
Conflict of interest
We declare that we have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zhang, Lc., Sha, Y., Wang, Zm. et al. 3D image of the middle ear ossicles: three protocols of post-processing based on multislice computed tomography. Eur Arch Otorhinolaryngol 268, 677–683 (2011). https://doi.org/10.1007/s00405-010-1441-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00405-010-1441-6