Skip to main content

Advertisement

Log in

Is it feasible to rely on intraoperative X ray in correcting hallux valgus?

  • Orthopaedic Surgery
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Background

The aim of the study was to prove whether the intraoperatively taken fluoroscopy pictures compared to the X rays taken 8 weeks and 3 months postoperatively picture the achieved correction reliably.

Method

In a prospective study, the pre- and postoperative standing foot X rays as well as the intraoperatively taken fluoroscopy pictures of 31 patients were analysed. The intermetatarsal angle (IMA) and the hallux valgus angle (HVA) were measured. In all cases, a tarso-metatarsal joint I arthrodesis combined with a distal soft tissue release was performed. The mean age was 54 (17–73) years.

Results

There was no significant difference between the measured angles in intraoperative fluoroscopy and standing X rays postoperatively taken.

Conclusions

Despite the consideration that fluoroscopic pictures lack the loading criteria, we found reliable results in IMA and HVA.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Leventen EO (1990) The Chevron procedure. Orthopaedics 13:973–976

    CAS  Google Scholar 

  2. Coetzee JC, Wickum D (2004) The Lapidus procedure: a prospective cohort outcome study. Foot Ankle Int 25:526–531

    PubMed  Google Scholar 

  3. Neylon TA, Johnson BA, Laroche RA (2001) Use of the Lapidus bunionectomy in first ray insufficiency. Clin Podiatr Med Surg 18:365–375

    PubMed  CAS  Google Scholar 

  4. Saxena A, Nguyen A, Nelsen E (2009) Lapidus bunionectomy: early evaluation of crossed lag screws versus locking plate with plantar lag screw. J Foot Ankle 48:170–179

    Article  Google Scholar 

  5. Patel S, Ford LA, Etcheverry J, Rush SM, Hamilton GA (2004) Modified Lapidus arthrodesis: rate of nonunion in 227 cases. Foot Ankle Surg 43:37–42

    Article  Google Scholar 

  6. Lee KM, Ahn S, Chung CY, Sung KH, Park MS (2012) Reliability and relationship of radiographic measurements in hallux valgus. Clin Orthop Relat Res 470:2613–2621

    Article  PubMed  Google Scholar 

  7. Elliot RR, Saxby TS, Whitehouse SL (2012) Intraoperative imaging in hallux valgus surgery. Foot Ankle Surg 18:19–21

    Article  PubMed  CAS  Google Scholar 

  8. Menke C, McGlamry M, Camasta C (2011) Lapidus arthrodesis with single lag screw and locking H-Plate. J Foot Ankle 50:377–382

    Article  Google Scholar 

  9. Walter M, Simons P, Nass K, Röser A (2011) Die arthrodese des tarsometatarsal-I gelenks mit einer plantaren Zuggurtungsosteosynthese. Orthop Traumatol 23:52–60

    Article  Google Scholar 

  10. Blitz NM, Lee T, Williams K, Barkan H, DiDimenico LA (2010) Early weight bearing after modified Lapidus arthrodesis: a multicenter review of 80 cases. Foot Ankle Surg 49:357–362

    Article  Google Scholar 

Download references

Conflict of interest

No conflict of interest

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. Gutteck.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gutteck, N., Wohlrab, D., Radetzki, F. et al. Is it feasible to rely on intraoperative X ray in correcting hallux valgus?. Arch Orthop Trauma Surg 133, 753–755 (2013). https://doi.org/10.1007/s00402-013-1720-y

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-013-1720-y

Keywords

Navigation