Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules

  • Chest
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

The purpose of this study was to investigate the diagnostic accuracy of low-dose helical computed tomography by comparing the number of nodules detected at low- and standard-dose CT. The prospective study included 25 patients who were referred to CT scan for the assessment of pulmonary metastases. All patients underwent CT examinations at both standard- (200 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation) and low-dose (50 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation). The number of nodules detected at each protocol was recorded. The size of the nodules was measured electronically and categorized as <3, 3–4.9, 5–6.9, 7–9.9, and ≥10 mm. Finally, the nodules detected at only standard- or low-dose CT were assessed for the underlying causes of discrepancy. In 25 patients, 533 nodules were detected at standard-dose, whereas 518 nodules were observed at low-dose CT. There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT (p>0.05). Four hundred ninety-one (87.7%) nodules were detected at both standard- or low-dose CT, 42 (7.5%) nodules were observed only at standard-dose CT, and 27 (4.8%) nodules were seen only at low-dose CT. The sensitivity of low-dose CT was 92.5% for all nodules, 88.1% for nodules <5 mm, and 97.4% for nodules ≥5 mm. No significant image artifact interfering with nodule detection was observed at low-dose CT. The low-dose CT protocol used in this study provided images of adequate quality; thus, it can be used reliably in the detection or exclusion of pulmonary nodules.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karabulut, N., Törü, M., Gelebek, V. et al. Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules. Eur Radiol 12, 2764–2769 (2002). https://doi.org/10.1007/s00330-002-1368-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-002-1368-4

Navigation