Skip to main content
Log in

Immunoscintigraphy of septic loosening of knee endoprosthesis: a retrospective evaluation of the antigranulocyte antibody BW 250/183

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

Immunoscintigraphy with the use of the antigranulocyte antibody BW 250/183 is a reliable method for detecting infection, especially in septic loosening of hip prostheses, for which purpose quantitative interpretation of the time-activity course is employed. Therefore, we retrospectively studied whether similar results could be achieved in knee prostheses. We verified 28 scintigraphic examinations in 26 patients by histology. Scintigraphy was performed during an early (4–6 h post injection) and a late phase (23–25 h post injection). Infection was diagnosed when activity around the knee prosthesis increased by more than 10% compared with bone marrow. We found a sensitivity and a negative predictive value of 100%, a specificity of 80%, a positive predictive value of 81% and an accuracy of 89%. Specificity and accuracy are lower than in the evaluation of hip prostheses; however, in comparison to other scintigraphic modalities, scintigraphy with the antigranulocyte antibody BW 250/183 is superior in excluding infection and has better specificity and accuracy. Therefore, as in the case of hip prostheses, the described methodology appears to be the scintigraphic modality of choice for knee prostheses.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.

Similar content being viewed by others

References

  1. Berberich R, Hennes P, Alexander C. Entzündungsnachweis und HAMA-Bildung nach Applikation des monoklonalen Antikörpers BW 250/183. Nuklearmedizin 1992; 31:70–73.

    CAS  PubMed  Google Scholar 

  2. Kaim A, Maurer T, Ochsner P, et al. Chronic complicated osteomyelitis of the appendicular skeleton: diagnosis with technetium-99m-labelled antigranulocyte antibody-immunoscintigraphy. Eur J Nucl Med 1997; 24:732–738.

    Article  CAS  PubMed  Google Scholar 

  3. Steinstraesser A, Oberhausen E. Granulocyte labelling kit BW 250/183. Results of the European Multicenter Trial. Nuklearmedizin 1996; 35:1–11.

    PubMed  Google Scholar 

  4. Boubaker A, Bischof Delaloye A, Blanc CH, et al. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses. Eur J Nucl Med 1995; 22:139–147.

    CAS  PubMed  Google Scholar 

  5. Sciuk J, Puskás C, Greitemann B, et al. White blood cell scintigraphy with monoclonal antibodies in the study of the infected endoprosthesis. Eur J Nucl Med 1992; 19:497–502.

    Google Scholar 

  6. Klett R, Khalisi A, Haas H, Puille M, Steiner D, Stürz H, Bauer R. Stufendiagnostik septischer Hüftendoprothesenlockerungen mittels Laborparametern und Antigranulozytenszintigraphie. Z Orthop 2001; 139:415–419.

    Article  CAS  PubMed  Google Scholar 

  7. Klett R, Steiner D, Puille M, Khalisi A, Matter HP, Stürz H, Bauer R. Antigranulocyte scintigraphy of septic loosening of hip prosthesis: influence of different analyzing methods. Nuklearmedizin 2001; 40:75–79.

    CAS  PubMed  Google Scholar 

  8. Mirra JM, Marder MD, Amstutz HC. The pathology of failed total joint arthroplasty. Clin Orthop 1982; 170:175–183.

    PubMed  Google Scholar 

  9. Love C, Tomas MB, Marwin SE, Pugliese PV, Palestro CJ. Role of nuclear medicine in diagnosis of the infected joint replacement. Radiographics 2001; 21:1229–1238.

    CAS  PubMed  Google Scholar 

  10. Steinstraesser A, Berberich R, Kuhlmann L, Zabori S, Schwarz A. Binding of the monoclonal antibody BW 250/183 to human granulocytes. Nuklearmedizin 1992; 31:57–63.

    PubMed  Google Scholar 

  11. Larikka MJ, Ahonen AK, Niemelä O, Puronto O, Junila JA, Hämäläinen MM, Britton K, Syrjälä HP.99mTc-ciprofloxacin (Infecton) imaging in the diagnosis of knee prosthesis infections. Nucl Med Commun 2002; 23:167–170.

    Article  CAS  PubMed  Google Scholar 

  12. Ivanéevic V, Perka C, Hasart O, Sandrock D, Munz DL. Imaging of low-grade bone infection with a technetium-99m labelled monoclonal anti-NCA-90 Fab' fragment in patients with previous joint surgery. Eur J Nucl Med 2002; 29:547–551.

    Article  Google Scholar 

  13. Niijhof MW, Oyen WJG, van Kampen A, Claessens RAMJ, van der Meer JWM, Corstens FHM. Hip and knee arthroplasty infection. In-111-IgG scintigraphy in 102 cases. Acta Orthop Scand 1997; 68:332–336.

    PubMed  Google Scholar 

  14. van Acker F, Nuyts J, Maes A, Vanquickenborne B, Stuyck J, Bellemans J, Vleugels S, Bormans G, Mortelmans L. FDG-PET,99mTc-HMPAO white blood cell SPET and bone scintigraphy in the evaluation of painful total knee arthroplasties. Eur J Nucl Med 2001; 28:1496–1504.

    Article  PubMed  Google Scholar 

  15. Zhuang H, Duarte PS, Pourdehnad M, Maes A, van Acker F, Shnier D, Garino JP, Fitzgerald RH, Alavi A. The promising role of18F-FDG PET in detecting infected lower limb prosthesis implants. J Nucl Med 2001; 42:44–48.

    CAS  PubMed  Google Scholar 

  16. Joseph TN, Mujtaba M, Chen AL, Maurer SL, Zuckerman JD, Maldjian C, Di Cesare PE. Efficacy of combined technetium-99m sulfur colloid/indium-111 leukocyte scans to detect infected total hip and knee arthroplasties. J Arthroplasty 2001; 16:753–758.

    Article  CAS  PubMed  Google Scholar 

  17. Scher DM, Pak K, Lonner JH, Finkel JE, Zuckerman JD, Cesare PE. The predictive value of indium-111 leukocyte scans in the diagnosis of infected total hip, knee, or resection arthroplasties. J Arthroplasty 2000; 15:295–300.

    CAS  PubMed  Google Scholar 

Download references

Acknowledgement

The authors are grateful to Dr. R.L. Snipes for linguistic assistance.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rigobert Klett.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Klett, R., Kordelle, J., Stahl, U. et al. Immunoscintigraphy of septic loosening of knee endoprosthesis: a retrospective evaluation of the antigranulocyte antibody BW 250/183. Eur J Nucl Med Mol Imaging 30, 1463–1466 (2003). https://doi.org/10.1007/s00259-003-1275-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-003-1275-1

Keywords

Navigation