Skip to main content

Advertisement

Log in

Peritumoural versus subareolar administration of technetium-99m nanocolloid for sentinel lymph node detection in breast cancer: preliminary results of a prospective intra-individual comparative study

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

The scintigraphic detection of sentinel lymph nodes (SNs) in early-stage breast cancer is a widely accepted diagnostic method. However, which radiotracer administration mode should be used is still controversial. This prospective study aimed to intra-individually compare the detection rates obtained after peritumoural versus subareolar injection with regard to SN number and localisation. Fifty-one women (age, 32–76 years) with breast cancer were investigated on two consecutive days. On day 1, 140–400 MBq technetium-99m nanocolloid was injected along the peripheral tumour margins. Static lymphoscintigrams of the axilla, thorax and neck were taken in various views 1 and 19 h p.i. On day 2, 10 MBq 99mTc-nanocolloid was injected subareolarly in the clock position of the tumour and dynamic and static scans were performed immediately. Thereafter, 30 MBq 99mTc-nanocolloid was administered peri-subareolarly and lymphoscintigrams were acquired in a dynamic and static manner. In 49/51 women, the different injection techniques disclosed the identical number and location of SNs in the axilla. In seven patients, the peritumoural injection detected additional SNs in the parasternal group. Axillary SNs were detected as early as 2–15 min following subareolar injection, both in the clock position and peri-subareolarly, as compared with about 1 h after peritumoural administration. Sixteen patients showed at least one tumour-positive SN, and nine also had tumour-positive non-SNs. One patient with a tumour-negative SN, visualised concordantly by both subareolar and peritumoural administration, demonstrated two metastatic non-SNs, yielding a false-negative rate of 5.9%. In conclusion, a simple subareolar injection in the clock position is sufficient for SN detection in breast cancer, if it is accepted that parasternal lymph node detection has no therapeutic consequences.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1. A

Similar content being viewed by others

References

  1. Keshtgar MRS, Ell PJ. Sentinel lymph node detection and imaging. Eur J Nucl Med 1999; 26:57–67.

    Google Scholar 

  2. Veronesi U, Paganelli G, Viale G, Galimberti V, Luini A, Zurrida S, Robertson C, Sacchini V, Veronesi P, Orvieto E, De Cicco C, Intra M, Tosi G, Scarpa D. Sentinel lymph node biopsy and axillary dissection in breast cancer: results in a large series. J Natl Cancer Inst 1999; 91:368–373.

    Google Scholar 

  3. Shivers S, Cox C, Leight G, Beauchamp D, Blumencranz P, Ross M, Reintgen D. Final results of the department of defense multicenter breast lymphatic mapping trial. Ann Surg Oncol 2002; 9:248–255.

    Google Scholar 

  4. Veronesi U, Paganelli G, Galimberti V, Viale G, Zurrida S, Bedoni M, Costa A, de Cicco C, Geraghty JG, Luini A, Sacchini V, Veronesi P. Sentinel-node biopsy to avoid axillary dissection in breast cancer with clinically negative lymph-nodes. Lancet 1997; 349:1864–1867.

    Google Scholar 

  5. Krag D, Weaver D, Ashikaga T, Moffat F, Klimberg VS, Shriver C, Feldman S, Kusminsky R, Gadd M, Kuhn J, Harlow S, Beitsch P. The sentinel node in breast cancer—a multicenter validation study. N Engl J Med 1998; 339:941–946.

    Google Scholar 

  6. Warmuth MA, Bowen G, Prosnitz LR, Chu L, Broadwater G, Peterson B, Leight G, Winer EP. Complications of axillary lymph node dissection for carcinoma of the breast: a report based on a patient survey. Cancer 1998; 83:1362–1368.

    Google Scholar 

  7. Schrenk P, Rieger R, Shamiyeh A, Wayand W. Morbidity following sentinel lymph node biopsy versus axillary lymph node dissection for patients with breast carcinoma. Cancer 2000; 88:608–614.

    Google Scholar 

  8. Borgstein PJ, Meijer S, Pijpers RJ, van Diest PJ. Functional lymphatic anatomy for sentinel node biopsy in breast cancer: echoes from the past and the periareolar blue method. Ann Surg 2000; 232:81–89.

    Google Scholar 

  9. Munz DL, ed. The sentinel lymph node concept in oncology—facts and fiction. Munich: Zuckschwerdt, 2001.

  10. Valdés Olmos RA, Tanis PJ, Hoefnagel CA, Nieweg OE, Muller SH, Rutgers EJ, Kooi ML, Kroon BB. Improved sentinel lymph node visualization in breast cancer by optimizing the colloid particle concentration and tracer dosage. Nucl Med Commun 2001; 22:579–586.

  11. Uren RF, Howman-Giles RB, Thompson JF, Malouf D, Ramsey-Stewart G, Niesche FW, Renwick SB. Mammary lymphoscintigraphy in breast cancer. J Nucl Med 1995; 36:1775–1780.

    Google Scholar 

  12. Roumen RMH, Geuskens LM, Valkenburg JGH. In search of the true sentinel node by different injection techniques in breast cancer patients. Eur J Surg Oncol 1999; 25:347–351.

    Google Scholar 

  13. McMasters KM, Wong SL, Martin RCG, Chao C, Tuttle TM, Noyes RD, Carlson DJ, Laidley AL, McGlothin TQ, Ley PB, Brown CM, Glaser RL, Pennington RE, Turk PS, Simpson D, Cerrito PB, Edwards M. Dermal injection of radioactive colloid is superior to peritumoral injection for breast cancer sentinel lymph node biopsy: results of a multiinstitutional study. Ann Surg 2001; 233:676–687.

    Google Scholar 

  14. Klimberg VS, Rubio IT, Henry R, Cowan C, Colvert M, Korourian S. Subareolar versus peritumoral injection for location of the sentinel lymph node. Ann Surg 1999; 229:860–864.

    Google Scholar 

  15. Smith LF, Cross MJ, Klimberg VS. Subareolar injection is a better technique for sentinel lymph node biopsy. Am J Surg 2000; 180:434–438.

    Google Scholar 

  16. Paganelli G, Galimberti V, Trifiro G, Travaini L, De Cicco C, Mazzarol G, Intra M, Rocca P, Prisco G, Veronesi U. Internal mammary node lymphoscintigraphy and biopsy in breast cancer. Q J Nucl Med 2002; 46:138–144.

    Google Scholar 

  17. Ivancevic V, Kettner B, Sandrock D, Maza S, Munz DL. Sentinel lymph node detection in breast cancer: is Tc-99m nanocolloid a suitable tracer? [abstract]. Eur J Nucl Med 2000; 27:1133.

    Google Scholar 

  18. Lee AC, Keshtgar MRS, Waddington WA, Ell PJ. The role of dynamic imaging in sentinel lymph node biopsy in breast cancer. Eur J Cancer 2002; 38:784–787.

    Google Scholar 

  19. Munz DL, Altmeyer P, Sessler MJ, Hör G. Axillary lymph node groups—the center in lymphatic drainage from the truncal skin in man. Clinical significance for management of malignant melanoma. Lymphology 1982; 15:143–147.

    Google Scholar 

  20. Morton DL, Wen D-R, Wong JH, Economou JS, Cagle LA, Storm FK, Foshag LJ, Cochran AJ. Technical details of intraoperative lymphatic mapping for early stage melanoma. Arch Surg 1992; 127:392–399.

    Google Scholar 

  21. Gershenwald JE, Thompson W, Mansfield PF, Lee JE, Colome MI, Tseng CH, Lee JJ, Balch CM, Reintgen DS, Ross MI. Multi-institutional melanoma lymphatic mapping experience: the prognostic value of sentinel lymph node status in 612 stage I or II melanoma patients. J Clin Oncol 1999; 17:976–983.

    Google Scholar 

  22. Statius Muller MG, van Leeuwen PA, de Lange-de Klerk ES, van Diest PJ, Pijpers R, Ferwerda CC, Vuylsteke RJ, Meijer S. The sentinel lymph node status is an important factor for predicting clinical outcome in patients with stage I or II cutaneous melanoma. Cancer 2001; 91:2401–2408.

    Google Scholar 

  23. Grant RN, Tabah EJ, Adair FE. The surgical significance of the subareolar lymph plexus in cancer of the breast. Surgery 1953; 33:71–78.

    Google Scholar 

  24. Halsell JT, Smith JR, Bentlage CR. Lymphatic drainage of the breast demonstrated by vital dye staining and radiography. Ann Surg 1963; 162:221–226.

    Google Scholar 

  25. Kern KA. Sentinel lymph node mapping in breast cancer using subareolar injection of blue dye. J Am Coll Surg 1999; 189:539–545.

    Google Scholar 

  26. Maza S, Valencia R, Geworski L, Zander A, Drager E, Winter H, Sterry W, Munz DL. Temporary shielding of hot spots in the drainage areas of cutaneous melanoma improves accuracy of lymphoscintigraphic sentinel lymph node diagnostics. Eur J Nucl Med 2002; 29:1399–1402.

    Google Scholar 

  27. Hultborn KA, Larsson LG, Ragnhult I. The lymph drainage from the breast to the axillary and parasternal lymph nodes studied with the help of colloidal Au-198. Acta Radiol 1955; 43:52–64.

    Google Scholar 

  28. Chao C, Wong SL, Woo C, Edwards MJ, Tuttle T, Noyes RD, Carlson DJ, Turk P, Simpson D, McMasters KM. Reliable lymphatic drainage to axillary sentinel lymph nodes regardless of tumor location within the breast. Am J Surg 2001; 182:307–311.

    Google Scholar 

Download references

Acknowledgements

The authors would like to thank the staff of technicians for their skilful technical aid, and Ms. Deborah Landry for editorial assistance.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dieter L. Munz.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Maza, S., Valencia, R., Geworski, L. et al. Peritumoural versus subareolar administration of technetium-99m nanocolloid for sentinel lymph node detection in breast cancer: preliminary results of a prospective intra-individual comparative study. Eur J Nucl Med Mol Imaging 30, 651–656 (2003). https://doi.org/10.1007/s00259-003-1128-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-003-1128-y

Keywords

Navigation