Abstract

Background

Diffusion imaging has proved to be a powerful tool for diagnosing ischemic lesions in the brain, and the technique is now being applied to other organs, including the kidneys. For quantitative studies it is important to define the normal values of the apparent diffusion coefficient (ADC), given the important physiological changes that occur in the kidney during early childhood it is likely that the ADC changes markedly during this period.

Objective

To evaluate the age dependent changes in the ADC of normal kidneys in the pediatric population.

Materals and methods

The whole kidney ADC was calculated for 62 pediatric patients on a 1.5-T system using a respiratory-triggered, single-shot diffusion tensor imaging sequence with b values of 50, 200, and 350 mm2/s.

Results

The ADC was found to increase with age with the largest increase being in the first year of life, the rate of change being described by a constant plus a power function, specifically 1349+{358.5*{age^0.34}}, (P<0.001).

Conclusion

The renal ADC changes significantly during childhood.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1a, b.
Fig. 2.
Fig. 3.

Similar content being viewed by others

References

  1. Muller MF, Prasad PV, Bimmler D, et al (1994) Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology 193:711–715

    CAS  PubMed  Google Scholar 

  2. Namimoto MF, Yamashita Y, Mitsuzaki K, et al (1999) Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion weighted echo-planar imaging. J Magn Reson Imaging 9:832–837

    Article  CAS  PubMed  Google Scholar 

  3. Ries M, Jones RA, Basseau F, et al (2001) Diffusion tensor MRI of the human kidney. J Magn Reson Imaging 14:42–49

    Article  CAS  PubMed  Google Scholar 

  4. Le Bihan D, Breton E, Lallemand D, et al (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168:497–505

    PubMed  Google Scholar 

  5. Duong TQ, Kim SG (2000) In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain. Magn Reson Med 43:393–402

    CAS  PubMed  Google Scholar 

  6. Murtz P, Flacke S, Traber F, et al (2002) Abdomen: diffusion weighted MR imaging with pulse triggered single shot sequences. Radiology 224:258–264

    PubMed  Google Scholar 

  7. Van Gelderen P, De Vleeschouwer MHM, DesPres D, et al (1994) Water diffusion and acute stroke. Magn Reson Med 31:154–163

    PubMed  Google Scholar 

  8. Wong EC, Cox RW, Song AW (1995) Optimised isotropic diffusion weighting. Magn Reson Med 34:139–143

    CAS  PubMed  Google Scholar 

  9. Toyoshima S, Noguchi K, Seto H, et al (2000) Functional evaluation of hydronephrosis by diffusion-weighted MR imaging. Relationship between apparent diffusion coefficient and split glomerular filtration rate. Acta Radiol 41:642–646

    Article  CAS  PubMed  Google Scholar 

  10. Anand SK (1991) Maturation of renal function. In: Taeusch HW, Ballard RA, Avery ME (eds) Diseases of the newborn, 6th edn. Saunders, Philadelphia, pp 837–855

  11. Peters AM, Henderson BL, Lui D (2000) Indexed glomerular filtration rate as a function of age and body size. Clin Sci 98:439–444

    CAS  PubMed  Google Scholar 

  12. Melham ER, Itoh R, Jones L, et al (2000) Diffusion tensor MR imaging of the brain: effect of diffusion weighting on trace and anisotropy measurements. Am J Neuroradiol 21:1813–1820

    CAS  PubMed  Google Scholar 

  13. Nusbaum AO, Tang CY, Wei T, et al (2000) Whole-brain diffusion MR histograms differ between MS subtypes. Neurology 54:1421–1427

    Google Scholar 

  14. Le Bihan (ed) (1995) Diffusion and perfusion magnetic resonance imaging: applications to functional MRI. Raven Press, New York

    Google Scholar 

  15. Pinnock C, Lin T, Smith T (2002) Fundamentals of anaesthesia. Greenwich Medical Media, London

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Richard A. Jones.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jones, R.A., Grattan-Smith, J.D. Age dependence of the renal apparent diffusion coefficient in children. Pediatr Radiol 33, 850–854 (2003). https://doi.org/10.1007/s00247-003-0982-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00247-003-0982-x

Keywords

Navigation