Abstract
Invasive and non-invasive monitoring allow for early detection of hemodynamic compromise, facilitating timely intervention and avoidance of further decline. While venous oximetry is useful for assessing the adequacy of systemic oxygen delivery (DO2), it is most often intermittent, invasive, and costly. Near-infrared spectroscopy (NIRS) oximetry allows for the non-invasive estimation of the adequacy of DO2. We assessed the correlation between cerebral NIRS oximetry and superior vena cava (SVC) and jugular venous (JV) oxygen saturations and between renal NIRS oximetry and inferior vena cava (IVC) oxygen saturations. Systematic review of the literature was conducted to identify studies with data regarding near-infrared spectroscopy and venous saturation. The PubMed, EMBASE, Medline, and Cochrane databases were queried using the following terms in isolation and various combinations: “congenital heart disease,” “near infrared spectroscopy,” “venous saturation,” and “pediatric.” Pediatric studies in which simultaneous NIRS oximetry and corresponding venous oxygen saturations were simultaneously collected after cardiac surgery or catheterization were identified. Data were pooled from these studies to analyze the correlation between NIRS oximetry and the corresponding venous oxygen saturations. A total of 16 studies with 613 patients were included in the final analyses. Data were present to compare cerebral and renal NIRS oximetry with corresponding venous oxygen saturation. Cerebral NIRS and SVC and JV oxygen saturations and renal NIRS and IVC oxygen saturations demonstrated strong degrees of correlation (r-value 0.70 for each). However, cerebral NIRS and IVC oxygen saturation had a week degree of correlation (r-value of 0.38). Pooled analyses demonstrate that cerebral NIRS oximetry correlates strongly with SVC or JV oxygen saturation while renal NIRS oximetry correlates strongly with IVC oxygen saturations. A weak correlation was noted between cerebral NIRS oximetry and IVC oxygen saturations.

Similar content being viewed by others
Data Availability
All data and materials, as well as software application, support our published claims and comply with field standards.
References
Welke KF, Diggs BS, Karamlou T, Ungerleider RM (2009) Comparison of pediatric cardiac surgical mortality rates from national administrative data to contemporary clinical standards. Annal Thorac Surg 87(1):216–222. https://doi.org/10.1016/j.athoracsur.2008.10.032
Bronicki RA (2011) Venous oximetry and the assessment of oxygen transport balance. Pediatr Crit Care Med 12(4):S21–S26. https://doi.org/10.1097/PCC.0b013e3182211667
Beal AL, Cerra FB (1994) Multiple organ failure syndrome in the 1990s. Systemic inflammatory response and organ dysfunction. JAMA 271(3):226–233
Rivers E, Nguyen B, Havstad S et al (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345(19):1368–1377. https://doi.org/10.1056/nejmoa010307
Ghanayem NS, Hoffman GM (2016) Near Infrared Spectroscopy as a Hemodynamic Monitor in Critical Illness. Pediatr Crit Care Med 17(8 1):S201–S206. https://doi.org/10.1097/pcc.0000000000000780
Tsang R, Checchia P, Bronicki RA (2016) Hemodynamic monitoring in the acute management of pediatric heart failure. Curr Cardiol Rev 12(2):112–116. https://doi.org/10.2174/1573403x12666151119165007
Rivers EP, Ander DS, Powell D (2001) Central venous oxygen saturation monitoring in the critically ill patient. Curr Opin Crit Care 7(3):204–211. https://doi.org/10.1097/00075198-200106000-00011
Pérez AC, Eulmesekian PG, Minces PG, Schnitzler EJ (2009) Adequate agreement between venous oxygen saturation in right atrium and pulmonary artery in critically ill children. Pediatr Crit Care Med 10(1):76–79. https://doi.org/10.1097/PCC.0b013e318193699d
Nagdyman N, Fleck T, Schubert S et al (2005) Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med 31(6):846–850. https://doi.org/10.1007/s00134-005-2618-0
Abdul-Khaliq H, Troitzsch D, Berger F, Lange PE (2000) Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation. Biomed Tech (Berl), 45(11):328–32. Regionale transkranielle Oxymetrie mit Nahinfrarot-Spektroskopie (NIRS) im Vergleich zur Messung der Sauerstoffsättigung im Bulbus jugularis bei Säuglingen und Kindern als Monitoring der zerebralen Oxygenierung. https://doi.org/10.1515/bmte.2000.45.11.328
Hoffman GM, Ghanayem NS, Scott JP, Tweddell JS, Mitchell ME, Mussatto KA (2017) Postoperative cerebral and somatic near-infrared spectroscopy saturations and outcome in hypoplastic left heart syndrome. Ann Thorac Surg 103(5):1527–1535. https://doi.org/10.1016/j.athoracsur.2016.09.100
Scott JP, Hoffman GM (2014) Near-infrared spectroscopy: exposing the dark (venous) side of the circulation. Paediatr Anaesth 24(1):74–88. https://doi.org/10.1111/pan.12301
Kreeger RN, Ramamoorthy C, Nicolson SC et al (2012) Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease. Ann Thorac Surg 94(5):1527–1533. https://doi.org/10.1016/j.athoracsur.2012.05.096
Bronicki RA, Checchia PA, Anas NG et al (2013) Cerebral and somatic oxygen saturations after repair of tetralogy of Fallot: effects of extubation on regional blood flow. Ann Thorac Surg 95(2):682–686. https://doi.org/10.1016/j.athoracsur.2012.07.017
Bronicki RA, Herrera M, Mink R et al (2010) Hemodynamics and cerebral oxygenation following repair of tetralogy of Fallot: the effects of converting from positive pressure ventilation to spontaneous breathing. Congenit Heart Dis 5(5):416–421. https://doi.org/10.1111/j.1747-0803.2010.00445.x
Altun D, Doğan A, Arnaz A et al (2020) Noninvasive monitoring of central venous oxygen saturation by jugular transcutaneous near-infrared spectroscopy in pediatric patients undergoing congenital cardiac surgery. Turk J Med Sci 50(5):1280–1287. https://doi.org/10.3906/sag-1911-135
Bhutta AT, Ford JW, Parker JG et al (2007) Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children. Pediatr Cardiol 28(1):34–41. https://doi.org/10.1007/s00246-006-1379-z
Dabal RJ, Rhodes LA, Borasino S, Law MA, Robert SM, Alten JA (2013) Inferior vena cava oxygen saturation monitoring after the Norwood procedure. Ann Thorac Surg 95(6):2114–2120. https://doi.org/10.1016/j.athoracsur.2013.01.076
Daubeney PE, Pilkington SN, Janke E, Charlton GA, Smith DC, Webber SA (1996) Cerebral oxygenation measured by near-infrared spectroscopy: comparison with jugular bulb oximetry. Ann Thorac Surg 61(3):930–934. https://doi.org/10.1016/0003-4975(95)01186-2
Gagnon MH, Kussman BD, Zhou L, DiNardo JA, Kheir JN (2020) Sensitivity of a next-generation NIRS device to detect low mixed venous oxyhemoglobin saturations in the single ventricle population. Anesth Analg 131(3):e138–e141. https://doi.org/10.1213/ane.0000000000004580
Gil-Anton J, Redondo S, Garcia Urabayen D, Nieto Faza M, Sanz I, Pilar J (2015) Combined cerebral and renal near-infrared spectroscopy after congenital heart surgery. Pediatr Cardiol 36(6):1173–1178. https://doi.org/10.1007/s00246-015-1139-z
Ginther R, Sebastian VA, Huang R et al (2011) Cerebral near-infrared spectroscopy during cardiopulmonary bypass predicts superior vena cava oxygen saturation. J Thorac Cardiovasc Surg 142(2):359–365. https://doi.org/10.1016/j.jtcvs.2010.12.021
Hansen JH, Schlangen J, Armbrust S, Jung O, Scheewe J, Kramer HH (2013) Monitoring of regional tissue oxygenation with near-infrared spectroscopy during the early postoperative course after superior cavopulmonary anastomosis. Eur J Cardiothorac Surg 43(2):e37-43. https://doi.org/10.1093/ejcts/ezs581
Knirsch W, Stutz K, Kretschmar O et al (2008) Regional cerebral oxygenation by NIRS does not correlate with central or jugular venous oxygen saturation during interventional catheterisation in children. Acta Anaesthesiol Scand 52(10):1370–1374. https://doi.org/10.1111/j.1399-6576.2008.01703.x
Marimón GA, Dockery WK, Sheridan MJ, Agarwal S (2012) Near-infrared spectroscopy cerebral and somatic (renal) oxygen saturation correlation to continuous venous oxygen saturation via intravenous oximetry catheter. J Crit Care 27(3):314.e13–8. https://doi.org/10.1016/j.jcrc.2011.10.002
Nagdyman N, Ewert P, Peters B, Miera O, Fleck T, Berger F (2008) Comparison of different near-infrared spectroscopic cerebral oxygenation indices with central venous and jugular venous oxygenation saturation in children. Paediatr Anaesth 18(2):160–166. https://doi.org/10.1111/j.1460-9592.2007.02365.x
Nasr VG, Bergersen LT, Lin HM et al (2019) Validation of a second-generation near-infrared spectroscopy monitor in children with congenital heart disease. Anesth Analg 128(4):661–668. https://doi.org/10.1213/ane.0000000000002796
Ortmann LA, Fontenot EE, Seib PM, Eble BK, Brown R, Bhutta AT (2011) Use of near-infrared spectroscopy for estimation of renal oxygenation in children with heart disease. Pediatr Cardiol 32(6):748–753. https://doi.org/10.1007/s00246-011-9960-5
Ranucci M, Isgrò G, De la Torre T, Romitti F, Conti D, Carlucci C (2008) Near-infrared spectroscopy correlates with continuous superior vena cava oxygen saturation in pediatric cardiac surgery patients. Paediatr Anaesth 18(12):1163–1169. https://doi.org/10.1111/j.1460-9592.2008.02783.x
Rescoe E, Tang X, Perry DA et al (2017) Cerebral near-infrared spectroscopy insensitively detects low cerebral venous oxygen saturations after stage 1 palliation. J Thorac Cardiovasc Surg 154(3):1056–1062. https://doi.org/10.1016/j.jtcvs.2017.03.154
Ricci Z, Garisto C, Favia I et al (2010) Cerebral NIRS as a marker of superior vena cava oxygen saturation in neonates with congenital heart disease. Paediatr Anaesth 20(11):1040–1045. https://doi.org/10.1111/j.1460-9592.2010.03430.x
Ranucci M, Isgro G, Carlucci C et al (2010) Central venous oxygen saturation and blood lactate levels during cardiopulmonary bypass are associated with outcome after pediatric cardiac surgery. Crit Care 14(4):R149. https://doi.org/10.1186/cc9217
Hoffman GM, Ghanayem NS, Kampine JM et al (2000) Venous saturation and the anaerobic threshold in neonates after the Norwood procedure for hypoplastic left heart syndrome. Annal Thorac Surg 70(5):1515–1520. https://doi.org/10.1016/s0003-4975(00)01772-0
Tweddell JS, Hoffman GM, Mussatto KA et al (2002) Improved survival of patients undergoing palliation of hypoplastic left heart syndrome: lessons learned from 115 consecutive patients. Circulation 106(12 Suppl 1):I82–I89
Tweddell JS, Ghanayem NS, Mussatto KA et al (2007) Mixed venous oxygen saturation monitoring after stage 1 palliation for hypoplastic left heart syndrome. Annal Thorac Surg 84(4):1301–1310. https://doi.org/10.1016/j.athoracsur.2007.05.047
Ranucci M, Isgro G, De La Torre T et al (2008) Continuous monitoring of central venous oxygen saturation (Pediasat) in pediatric patients undergoing cardiac surgery: a validation study of a new technology. J Cardiothorac Vasc Anesth 22(6):847–852. https://doi.org/10.1053/j.jvca.2008.04.003
Goldman SM, Sutter FP, Wertan MA, Ferdinand FD, Trace CL, Samuels LE (2006) Outcome improvement and cost reduction in an increasingly morbid cardiac surgery population. Seminars in cardiothoracic and vascular anesthesia 10(2):171–175. https://doi.org/10.1177/1089253206289009
Madsen PL, Skak C, Rasmussen A, Secher NH (2000) Interference of cerebral near-infrared oximetry in patients with icterus. Anesth Analg 90(2):489–493. https://doi.org/10.1097/00000539-200002000-00046
Acknowledgements
None
Funding
This study did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Contributions
RSL, SF, and JR contributed to the study conception and design. Material preparation, data collection, and analysis were performed by JSF, EGV, DS, and AD. The first draft of the manuscript was written by RSL, JSF, SF, and JR commented on previous versions of the manuscript. All authors read and approved the final manuscript. Reviewing and editing was done by RAB and EGV.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Statement of human rights
The Study has been approved by the appropriate institutional ethics committee and has been performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Loomba, R.S., Rausa, J., Sheikholeslami, D. et al. Correlation of Near-Infrared Spectroscopy Oximetry and Corresponding Venous Oxygen Saturations in Children with Congenital Heart Disease. Pediatr Cardiol 43, 197–206 (2022). https://doi.org/10.1007/s00246-021-02718-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00246-021-02718-7