Abstract
There has been a recent upsurge in the use of bone anchors in repairing hand tendon injuries, which substantiates our use of Mitek anchors in the late 1990s with good results. The objective of this study was to describe our technique of using Mitek bone anchors to repair open mallet and open central slip avulsion injuries, hence evaluating their post-operative outcomes. Four patients with open mallet injury and ten patients with open central slip avulsions were treated using the Mitek mini bone anchors. In each case, the extensor tendon was shaved off its point of insertion on the middle or distal phalanx. All patients were operated in within 2 days of the open injury without any conservative measures pre-operatively. Post-operatively, the joint was maintained in an extension with a single trans-articular Kirschner wire or splint for 2 weeks, followed by gradual mobilization and active and passive exercises. Each patient underwent an objective evaluation to assess joint stability, the joint’s range of motion and grip strength compared to the uninjured side. Patients also underwent a subjective evaluation at the end of the follow-up period. The operative procedure was successful in all but one patient. One patient needed a relook procedure. Two patients were lost to follow-up, while the rest were followed up for a mean duration of 11 months (range = 5–24 months). Subjectively, two patients had excellent results, seven had good results, two had fair, and one achieved poor results. The Mitek bone anchor is a useful tool to treat open extensor tendon injuries, especially ones where the tendon has been shaved off at its insertion on the bone.
Similar content being viewed by others
References
Robb WA (1959) The results of treatment of mallet finger. J Bone Joint Surg Br 41-B:546–549
Marty J, Porcher B, Autissier R (1983) [Hand injuries and occupational accidents. Statistics and prevention]. Ann Chir Main 2(4):368–370
Kleinert HE, Verdan C (1983) Report of the Committee on Tendon Injuries (International Federation of Societies for Surgery of the Hand). J Hand Surg Am 8(5 Pt 2):794–798
Baratz M, Schmidt CC, Hughes TB (2005) Extensor tendon injuries, in green’s operative hand surgery. In: D Green et al. eds Churchill Livingstone, New York p. 187–217
Chao JD et al (2004) Central slip tenotomy for the treatment of chronic mallet finger: an anatomic study. J Hand Surg Am 29(2):216–219
Sorene ED, Goodwin DR (2004) Tenodermodesis for established mallet finger deformity. Scand J Plast Reconstr Surg Hand Surg 38(1):43–45
Kaleli T, Ozturk C, Ersozlu S (2003) External fixation for surgical treatment of a mallet finger. J Hand Surg Br 28(3):228–230
Snow JW (1976) A method for reconstruction of the central slip of the extensor tendon of a finger. Plast Reconstr Surg 57(4):455–459
Aiache A, Barsky AJ, Weiner DL (1970) Prevention of the boutonniere deformity. Plast Reconstr Surg 46(2):164–167
Rehak DC et al (1994) The Mitek bone anchor: application to the hand, wrist and elbow. J Hand Surg Am 19(5):853–860
Skoff HD et al (1995) Bone suture anchors in hand surgery. J Hand Surg Br 20(2):245–248
Kato N et al (2003) Primary repair of the collateral ligament of the proximal interphalangeal joint using a suture anchor. Scand J Plast Reconstr Surg Hand Surg 37(2):117–120
Bickert B, Sauerbier M, Germann G (2000) Scapholunate ligament repair using the Mitek bone anchor. J Hand Surg Br 25(2):188–192
Chan JC, Purcell EM, Kelly JL (2007) Surgical repair of central slip avulsion injuries with Mitek bone anchor—retrospective analysis of a case series. Hand Surg 12(1):29–34
Ulkur E et al (2005) Repair of chronic mallet finger deformity using Mitek micro arc bone anchor. Ann Plast Surg 54(4):393–396
Saetta JP, Phair IC, Quinton DN (1992) Ulnar collateral ligament repair of the metacarpo-phalangeal joint of the thumb: a study comparing two methods of repair. J Hand Surg Br 17(2):160–163
McDermott TP, Levin LS (1998) Suture anchor repair of chronic radial ligament injuries of the metacarpophalangeal joint of the thumb. J Hand Surg Br 23(2):271–274
Cluett J et al (1999) Repair of central slip avulsions using Mitek Micro Arc bone anchors. An in vitro biomechanical assessment. J Hand Surg Br 24(6):679–682
Newport ML, Blair WF, Steyers CM Jr (1990) Long-term results of extensor tendon repair. J Hand Surg Am 15(6):961–966
Paul C, Stephens ED, Beata Niechoda, Tracey Clarke, Mark P (2005) Gianoutsos, tendons of the hand: anatomy, repair, healing, and rehabilitation, in repair and regeneration of ligaments, tendons, and joint capsule, WR Walsh, Editor. Humana Press. p. 324
McCallister WV et al (2006) Comparison of pullout button versus suture anchor for zone I flexor tendon repair. J Hand Surg Am 31(2):246–251
Shokrollahi K, Anchor M (2008) Simple method to release sutures without force. J Plast Reconstr Aesthet Surg 61:1134
Kato H et al (1999) Surgical repair of acute collateral ligament injuries in digits with the Mitek bone suture anchor. J Hand Surg Br 24(1):70–75
Hallock GG (1994) The Mitek Mini GII anchor introduced for tendon reinsertion in the hand. Ann Plast Surg 33(2):211–213
Wiedrich TS (1997) The use of suture anchors in the hand and wrist. Oper Tech Plast Reconstr Surg 4(1):42–48
Statement of conflict of interest
None of the authors have or had any conflict of interest or financial and personal relationships with other people or organizations that could inappropriately influence (bias) their work. This is declared with reference to potential conflicts of interest including employment, consultancies, stock ownership, honoraria, paid expert testimony, patent applications/registrations, and grants or other funding.
Funding status for this study
No funding was acquired for this study.
Ethics
Ethical Committee approval was taken.
We declare that investigations were carried out to a high ethical standard. There was informed consent taken before the operative procedure.
Author information
Authors and Affiliations
Corresponding author
Additional information
Details of research presentations
The Repair of Central Slip of Extensor Tendon and Open Mallet using Mitek Mini Bone Anchors: A retrospective study;
Rights and permissions
About this article
Cite this article
Mehdi, S.Y., Masood, Q., Lawlor, D. et al. Repair of the central slip of extensor tendon and the open mallet using Mitek mini bone anchors. Eur J Plast Surg 34, 13–17 (2011). https://doi.org/10.1007/s00238-010-0440-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00238-010-0440-6