Abstract
We present a study that helped optimize a three-dimensional isotropic contrast-enhanced MR angiographic (CE-MRA) technique, using sensitivity encoding (SENSE) and random elliptic centric k-space filling. Two-dimensional gradient-echo sequence (TR/TE/flip angle 3.4/0.97/40°) was used to generate time–intensity curves in porcine carotid arteries for a fixed dose of Gd-DTPA (0.02 mmol/kg) at the following intravenous injection rates: 0.1, 0.3, 0.5, 1.0, 1.5, 2.0, and 3.0 ml/s. The time of contrast arrival and time to peak were recorded. Based on the time–intensity curves, three-dimensional high-resolution isotropic (1 mm3) CE-MRA sequence (TR/TE/flip angle: 4.9/2.4/30°), using SENSE (reduction factor of 2) and random elliptic centric k-space filling, was initiated twice for each of the above injection rates: first at the time of contrast arrival and second at the time of peak contrast. The three-dimensional CE-MRA images were analyzed for artifacts, signal-to-noise ratio, and venous contamination. For the three-dimensional CE-MRA acquisitions that were initiated at the time of contrast arrival, there was a gradual improvement in signal-to-noise ratio (SNR) in the carotid arteries with increasing injection rate. The same trend was not observed for the acquisitions that were initiated at the time of peak contrast. SENSE combined with random elliptic k-space acquisition in CE-MRA allows for higher SNR with fewer ringing artifacts at faster contrast injection rates.




Similar content being viewed by others
References
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962
Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P (2000) Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 12:671–677
Golay X, Brown S, Ryuta I, Melhem ER (2001) Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE). AJNR Am J Neuroradiol 22:1615–1619
Willinek WA, Gieseke J, Conrad R, Strunk H, Hoogeveen R, von Falkenhausen M, Keller E, Urbach H, Kuhl CK, Schild HH (2002) Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology 225:583–588
Rusinek H, Lee VS, Johnson G (2001) Optimal dose of Gd-DTPA in dynamic MR studies. Magn Reson Med 46:312–316
Carroll TJ, Korosec FR, Swan JS, Hany TF, Grist TM, Mistretta CA (2001) The effect of injection rate on time-resolved contrast-enhanced peripheral MRA. J Magn Reson Imaging 14:401–410
Wilman AH, Riederer SJ (1997) Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magn Reson Med 38:793–802
Svensson J, Petersson JS, Stahlberg F, Larsson EM, Leander P, Olsson LE (1999) Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA. J Magn Reson Imaging 10:919–928
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Riedy, G., Golay, X. & Melhem, E.R. Three-dimensional isotropic contrast-enhanced MR angiography of the carotid artery using sensitivity-encoding and random elliptic centric k-space filling: technique optimization. Neuroradiology 47, 668–673 (2005). https://doi.org/10.1007/s00234-005-1416-2
Received:
Accepted:
Published:
Issue Date: