Skip to main content

Advertisement

Log in

X-Ray Diffraction on Cyclically Loaded Osteons

  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Abstract.

The results of a study on the fine structural distortion due to the two previously observed types of degradation in cyclically loaded single osteons (i.e., stiffness degradation and pinching effect) are presented. Fully calcified longitudinal and alternate osteons were isolated from 350-μm-thick longitudinal sections of human femoral cortical bone. The samples were prepared from 500-μm-long central cylindrical portions of an osteon, whose two ends were penetrating into rectangular lugs for fixation to an electromechanical device that cyclically loaded the samples. This device was connected to a microwave micrometer and a recorder. The structural distortions induced by cyclic loading were investigated by high- and low-angle X-ray diffraction on conventional and synchrotron radiation sources. Cyclic loading results in a reduction in the degree of orientation of apatite crystallites, especially in longitudinal osteons, in which the most abundant longitudinal lamellae are not protected against buckling by transverse lamellae as they are in alternate osteons. In contrast, the degree of orientation of collagen fibrils does not seem to be affected by cycling loading in the two osteon types, possibly because the disorientation of collagen fibrils is, within limits, a reversible process. Finally, the contrast between the disorientation of inorganic crystallites and the apparently unaltered distribution of collagen fibrils suggests that the degradation of cyclically loaded osteons may be due to a separation of the crystallites from the fibrils.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 6 June 1996 / Accepted: 7 August 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ascenzi, A., Benvenuti, A., Bigi, A. et al. X-Ray Diffraction on Cyclically Loaded Osteons. Calcif Tissue Int 62, 266–273 (1998). https://doi.org/10.1007/s002239900428

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002239900428

Navigation