Skip to main content
Log in

Multidimensional on-line solid-phase extraction (SPE) using restricted access materials (RAM) in combination with molecular imprinted polymers (MIP)

  • Original paper
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract.

A novel, multidimensional SPE sample-processing platform for complex fluids, which relies on the combination of small LC columns packed with restricted access materials (RAM) and molecular imprinted polymers (MIP) is described. It is called the Six-S ProcEdure (Six-SPE). Six-SPE involves a size-selective sample-separation step followed by a solvent-switch. Six-SPE efficiently removes interfering matrix components of complex aqueous samples and creates optimal conditions for selective recognition, i.e. binding of the imprinted target analyte(s). A Six-SPE analysis cycle consists of four distinct steps: 1. separation of a given sample (e.g. plasma, urine, saliva, milk, etc.) by adsorptive extraction (e.g. reversed-phase partitioning) of low molecular weight components on to the stationary phase of a RAM column and simultaneous size-exclusion, i.e. quantitative disposal of macromolecular matrix constituents to waste; 2. desorption and transfer of the extract from the RAM column on to a series-connected MIP column using a pure organic mobile phase (e.g. acetonitrile) [solvent switch]; 3. molecular recognition, i.e. selective binding of the target analyte(s) by a tailor-made MIP column; and 4. desorption and transfer of the analyte fraction on to a series-connected separation (e.g. HPLC) and/or detection system (e.g. UV, FD, MS).

As a first application we coupled the Six-SPE platform to a conventional HPLC system for on-line analysis of the analgesic drug Tramadol in human plasma using LiChrospher ADS RP-18 as a RAM precolumn for the fractionation step in the first and second chromatographic dimension and a Tramadol imprinted polymer for the molecular recognition step, i.e. third chromatographic dimension.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Boos, KS., Fleischer, C. Multidimensional on-line solid-phase extraction (SPE) using restricted access materials (RAM) in combination with molecular imprinted polymers (MIP). Fresenius J Anal Chem 371, 16–20 (2001). https://doi.org/10.1007/s002160100831

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002160100831

Navigation