Abstract
A selective and sensitive method is proposed for the determination of mercury by anodic stripping voltammetry after its preconcentration from the gas phase. Mercury from the sample solution is reduced to elemental Hg by SnCl2 and volatilized by the bubbles of a carrier gas. The gas containing mercury vapour is dried and passed through a capillary onto a gold coated graphite electrode. An anodic stripping voltam-mogram is recorded from 0.1 mol/1 HClO4 + 3 × 10−3 mol/1 HCl solution. The calibration curve is linear from 1 × 10−9 to 4 × 10−8 mol/1 Hg(NO3)2. The absolute detection limit is 0.46 ng Hg. The relative standard deviations for 4 × 10−9 mol/1 and 2 × 10−8 mol/1 Hg(NO3)2 are 9.8% and 6.1%, respectively n = 5).
Similar content being viewed by others
References
Huiliang H, Jagner D, Renman L (1987) Anal Chim Acta 201: 1–9
Rievaj M, Bustin D (1992) Analyst 117: 1471–1472
Golimowski J, Orzechowska A, Tykarska A (1995) Fresenius J Anal Chem 351: 656–659
Wang J, Tian B (1993) Anal Chim Acta 274: 1–6
Jaya S, Rao TP, Rao GP (1985) Analyst 110: 1361–1364
Loung L, Vydra F (1974) J Electroanal Chem 50: 379–386
Fukai R, Huynh-Ngoc L (1976) Anal Chim Acta 83: 375–379
Lexa J, Stulik K (1989) Talanta 36: 843–848
Liu K, Wu Q, Liu H (1990) Analyst 115: 835–837
Cai X, Kalcher K, Diewald W, Neuhold C, Magee RJ (1993) Fresenius J Anal Chem 345: 25–31
Scholz F, Nitschke L, Gunter H (1987) Anal Chim Acta 199: 167–171
Trittler R, Schilcher H (1994) Fresenius J Anal Chem 349: 659–660
Sykut K, Cukrowski I, Cukrowska E (1980) J Electroanal Chem 115: 137–142
Cukrowski I (1980) Polish Patent No 106555
Hatle M (1987) Talanta 34: 1001–1007
Coles LE, Guthenberg H, Kato T, Kojima K (1985) Pure Appl Chem 57: 1507–1514
Adeloju SB, Dhindsa HS, Tandon RK (1994) Anal Chim Acta 285: 359–364
Puk R, Weber JH (1994) Anal Chim Acta 292: 175–183
Yan X-P, Ni Z-M, Guo Q-L (1993) Anal Chim Acta 272: 105–114
Welz B, Tsalev DL, Sperling M (1992) Anal Chim Acta 261: 91–103
Landi S, Fagioli F, Locatelli C, Vecchietti (1990) Analyst 115: 173–177
Bersier PM, Howell J, Bruntlett C (1994) Analyst 119: 219–232
Wang J (1985) Stripping analysis. VCH, Deerfield Beach, p 17
Yamamoto Y, Kumamaru T, Shiraki A (1978) Fresenius Z Anal Chem 292: 273–277
Welz B, Schubert-Jacobs M (1988) Fresenius Z Anal Chem 331: 324–329
Szmyd E, Baranowska I (1994) Fresenius J Anal Chem 350: 178–180
Guo T, Baasner J (1993) Anal Chim Acta 278: 189–196
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Korolczuk, M. Sensitive and selective determination of mercury by differential pulse stripping voltammetry after accumulation of mercury vapour on a gold plated graphite electrode. Fresenius J Anal Chem 357, 389–391 (1997). https://doi.org/10.1007/s002160050175
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s002160050175