Abstract
The present research is focused on the use and evaluation of hydrogen, as a more sustainable alternative to helium, within the context of fast flow modulation comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry. In such a respect, a comparison was made between the two mobile phases in terms of speed and overall chromatography performance. All experiments were carried out by using the following column set: low polarity with dimensions 10 m × 0.25 mm ID × 0.25 µm df and medium polarity with dimensions 2 m × 0.10 mm ID × 0.10 µm df. Fundamental gas chromatography parameters (efficiency, resolution) were measured under different experimental conditions, using the two carrier gases. Efficiency was measured in both the first and second dimensions, using a probe compound under isothermal conditions; after defining the optimum carrier gas conditions, a mixture containing 20 pesticides was analyzed to measure resolution, again in the first and second dimensions, using a temperature program. It was found (as expected) that a similar chromatography performance could be attained when using hydrogen, albeit with a circa 25% reduction in analysis time. Signal-to-noise ratios of the pesticides were calculated, using both carrier gases, with such values generally reduced (on average by 14%) when using hydrogen. Finally, a comparison was made between mass spectral profiles obtained analyzing the pesticides and fatty acid methyl esters using the two mobile phases. Even though mass spectral differences were observed, the ion profiles could be considered generally similar.
Graphical abstract
Similar content being viewed by others
References
Dömötörová M, Kirchner M, Matisová E, De Zeeuw J. Possibilities and limitations of fast GC with narrow-bore columns. J Sep Sci. 2006. https://doi.org/10.1002/jssc.200500472.
Ettre LS, Hinshaw JV. Basic relationships of gas chromatography. Cleveland: Advanstar Communications Inc; 1993.
Muñoz-Guerra JA, Prado P, García-Tenorio SV. Use of hydrogen as a carrier gas for the analysis of steroids with anabolic activity by gas chromatography-mass spectrometry. J Chromatogr A. 2011. https://doi.org/10.1016/j.chroma.2011.08.009.
Nnaji CN, Williams KC, Bishop JM, Verbeck GF. Hydrogen as a GC/MS carrier and buffer gas for use in forensic laboratories. Sci Justice. 2015. https://doi.org/10.1016/j.scijus.2015.01.003.
Liu Z, Phillips JB. Comprehensive two-dimensional gas chromatography using an on-column thermal modulator interface. J Chromatogr Sci. 1991. https://doi.org/10.1093/chromsci/29.6.227.
Gaines RB, Ledford EB, Stuart JD. Analysis of water samples for trace levels of oxygenate and aromatic compounds using headspace solid-phase microextraction and comprehensive two-dimensional gas chromatography. J Microcolumn Sep. 1998. https://doi.org/10.1002/(SICI)1520-667X(1998)10:7<597::AID-MCS6>3.0.CO;2-B
Seeley JV, Schimmel NE, Seeley SK. The multi-mode modulator: a versatile fluidic device for two-dimensional gas chromatography. J Chromatogr A. 2018. https://doi.org/10.1016/j.chroma.2017.06.030.
Aloisi I, Giocastro B, Ferracane A, Salerno TMG, Zoccali M, Tranchida PQ, Mondello L. Preliminary observations on the use of a novel low duty cycle flow modulator for comprehensive two-dimensional gas chromatography. J Chromatogr A. 2021. https://doi.org/10.1016/j.chroma.2021.462076.
Beens J, Janssen HG, Adahchour M, Brinkman UATh. Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography. J Chromatogr A. 2005. https://doi.org/10.1016/j.chroma.2005.05.086.
Blumberg LM, David F, Klee MS, Sandra P. Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography. J Chromatogr A. 2008. https://doi.org/10.1016/j.chroma.2008.02.044.
Acknowledgements
The authors thank LECO Corporation and Merck Life Science for their continuous support.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethics approval
Not applicable.
Source of biological material
Not applicable.
Statement on animal welfare
Not applicable.
Conflict of interest
The authors declare no competing interests. The author Luigi Mondello is an editor of this journal but was not involved in the peer review of this article.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Published in the topical collection featuring Sustainability in (Bio-)Analytical Chemistry.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Galletta, M., Zoccali, M., Jones, N. et al. Flow-modulated comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry: use of hydrogen as a more sustainable alternative to helium. Anal Bioanal Chem 414, 6371–6378 (2022). https://doi.org/10.1007/s00216-022-04086-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-022-04086-4