Accuracy of CT-assisted pedicle screw placement after CT-controlled, presurgical guide wire implantation in traumatic and pathological fractures in the thoracic spine

  • Original Article
  • Published:
European Journal of Trauma and Emergency Surgery Aims and scope Submit manuscript

Abstract

Introduction

The aim of this study was to evaluate the accuracy of pedicle screw placement after computed tomography (CT)-assisted positioning of guide wires and subsequent insertion of transpedicular screws in particularly narrow pedicles in the thoracic spine. Transpedicular pedicle screw placement has been commonly used for a number of decades. However, a significant number of malpositioned screws still occur, especially in the thoracic spine, potentially correlating with relevant complications, e.g., neurological deterioration.

Patients and methods

A retrospective analysis was performed after CT-assisted and -controlled implantation of guide wires into the pedicle. A total of 39 patients underwent dorsal spondylodesis using two different internal fixation systems, i.e., with a cannulated or a solid screw design. The postoperative screw position was evaluated with CT scans in three planes in a total of 254 screws.

Results

The number of the screws inserted at each level were as follows (total n = 326): T1, n = 8; T2, n = 26; T3, n = 26; T4, n = 36; T5, n = 50; T6, n = 37; T7, n = 38; T8, n = 32; T9, n = 24; T10, n = 18; T11, n = 10; T12, n = 6. Indications for the operative treatment were fractures, tumors, and infectious diseases. A total of 254 screws inserted were evaluated by CT scan in order to determine the screw position inside the pedicle and potential perforation of the pedicle wall. The overall rate of pedicle wall perforation was 7.5%, including 1.2% perforations of the medial wall. A significant correlation between the perforation rate and the type of fixation system in favor of the cannulated system was found (P = 0.033). During the study, no revision surgery due to screw misplacement was necessary. None of the treated patients showed neurological deterioration after screw implantation during the presented study.

Conclusion

The CT-assisted pedicle screw implantation procedure using guide wires implanted prior to surgery is an accurate, reliable, and safe method for dorsal spondylodesis in the treatment of a variety of spinal instabilities, including fractures, tumors, and infections.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Harrington PR. Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am. 1962;44-A:591–610.

    PubMed  CAS  Google Scholar 

  2. Moe JH. Modern concepts of treatment of spinal deformities in children and adults. Clin Orthop Relat Res. 1980;(150):137–53.

  3. Roy-Camille R, Saillant G, Berteaux D, Salgado V. Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol. 1976;15:2–16.

    PubMed  CAS  Google Scholar 

  4. Dick W. The “fixateur interne” as a versatile implant for spine surgery. Spine. 1987;12:882–900.

    Article  PubMed  CAS  Google Scholar 

  5. Christodoulou AG, Apostolou T, Ploumis A, Terzidis I, Hantzokos I, Pournaras J. Pedicle dimensions of the thoracic and lumbar vertebrae in the Greek population. Clin Anat. 2005;18:404–8.

    Article  PubMed  Google Scholar 

  6. McLain RF, Ferrara L, Kabins M. Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients. Spine. 2002;27:2467–71.

    Article  PubMed  Google Scholar 

  7. Kothe R, O’Holleran JD, Liu W, Panjabi MM. Internal architecture of the thoracic pedicle. An anatomic study. Spine. 1996;21:264–70.

    Article  PubMed  CAS  Google Scholar 

  8. Graichen H, Putz R. Anatomical and functional aspects of the thoracic and lumbar spine. Orthopade. 1999;28:424–31.

    Article  PubMed  CAS  Google Scholar 

  9. Arand M, Hartwig E, Hebold D, Kinzl L, Gebhard F. Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study. Unfallchirurg. 2001;104:1076–81.

    Article  PubMed  CAS  Google Scholar 

  10. Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr. In vivo accuracy of thoracic pedicle screws. Spine. 2001;26:2340–6.

    Article  PubMed  Google Scholar 

  11. Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine. 1990;15:11–4.

    Article  PubMed  CAS  Google Scholar 

  12. Hart RA, Hansen BL, Shea M, Hsu F, Anderson GJ. Pedicle screw placement in the thoracic spine: a comparison of image-guided and manual techniques in cadavers. Spine. 2005;30:E326–31.

    Article  PubMed  Google Scholar 

  13. Husted DS, Yue JJ, Fairchild TA, Haims AH. An extrapedicular approach to the placement of screws in the thoracic spine: an anatomic and radiographic assessment. Spine. 2003;28:2324–30.

    Article  PubMed  Google Scholar 

  14. White KK, Oka R, Mahar AT, Lowry A, Garfin SR. Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular techniques. Spine. 2006;31:E355–8.

    Article  PubMed  Google Scholar 

  15. Cinotti G, Gumina S, Ripani M, Postacchini F. Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine. 1999;24:114–9.

    Article  PubMed  CAS  Google Scholar 

  16. Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM. Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am. 1995;77:1193–9.

    PubMed  CAS  Google Scholar 

  17. Xu R, Ebraheim NA, Ou Y, Yeasting RA. Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine. 1998;23:1065–8.

    Article  PubMed  CAS  Google Scholar 

  18. Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine. 1995;20:1399–405.

    PubMed  CAS  Google Scholar 

  19. Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine. 2001;26:2049–57.

    Article  PubMed  CAS  Google Scholar 

  20. Kim KD, Patrick Johnson J, Bloch BS O, Masciopinto JE. Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine. 2001;26:360–4.

    Article  PubMed  CAS  Google Scholar 

  21. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine. 2004;29:333–42.

    Article  PubMed  Google Scholar 

  22. Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine. 1996;21:1320–4.

    Article  PubMed  CAS  Google Scholar 

  23. Ebraheim NA, Xu R, Ahmad M, Yeasting RA. Projection of the thoracic pedicle and its morphometric analysis. Spine. 1997;22:233–8.

    Article  PubMed  CAS  Google Scholar 

  24. Panjabi MM, O’Holleran JD, Crisco JJ III, Kothe R. Complexity of the thoracic spine pedicle anatomy. Eur Spine J. 1997;6:19–24.

    Article  PubMed  CAS  Google Scholar 

  25. Shapiro SA, Snyder W. Spinal instrumentation with a low complication rate. Surg Neurol. 1997;48(6):566–74.

    Article  PubMed  CAS  Google Scholar 

  26. Frankel HL, Hancock DO, Hyslop G, Melzak J, Michaelis LS, Ungar GH, Vernon JD, Walsh JJ. The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegia. I. Paraplegia. 1969;7:179–92.

    Article  PubMed  CAS  Google Scholar 

  27. Waters RL, Adkins RH, Yakura JS. Definition of complete spinal cord injury. Paraplegia. 1991;29:573–81.

    Article  PubMed  CAS  Google Scholar 

Download references

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to B. Maier.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ploss, C., Maier, B., Mack, M.G. et al. Accuracy of CT-assisted pedicle screw placement after CT-controlled, presurgical guide wire implantation in traumatic and pathological fractures in the thoracic spine. Eur J Trauma Emerg Surg 37, 121–126 (2011). https://doi.org/10.1007/s00068-010-0069-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00068-010-0069-y

Keywords

Navigation