Abstract
A new computer program was developed to calculate the absorbed dose. The program is based on the use of the convolution method and abdominal SPECT/MR fusion images. The applicability of the method was demonstrated by using data from111In-labeled thrombocyte and99mTc-labeled colloid studies of three healthy volunteers. Dose distributions in the volunteers and the average absorbed doses in liver and spleen were calculated. The average doses for99mTc-labeled colloid study were 0.07 ± 0.02 (liver) and 0.046 ± 0.005 mGy/MBq (spleen). The results are in good agreement with a Monte Carlo (MC) based method (0.074 for liver and 0.077 mGy/MBq for spleen) used by the International Commission on Radiological Protection (ICRP). For111In-labeled thrombocyte study the doses were 0.33 ± 0.05 (liver) and 8.9 ± 1.2 mGy/MBq (spleen) versus 0.730 and 7.50, respectively. The differences in dose estimates in the111In-labeled thrombocyte study are mainly due to the approximation used in activity quantitation. Convolution of the activity distribution with a point dose kernel is an effective method for calculating absorbed dose distribution in a homogeneous media. Activity distribution must be aligned to anatomical data in order to utilize the calculated dose distribution. The program developed is applicable to and practical for clinical use provided that the input data needed are available.
Similar content being viewed by others
References
Loevinger R, Budinger TF, Watson EE. MIRD primer for absorbed dose calculation. New York, Society of Nuclear Medicine, 1988.
Stabin MG. MIRDOSE: Personal Computer Software for Internal Dose Assessment in Nuclear Medicine.J Nucl Med 37: 538–546, 1996.
Erdi AK, Erdi YE, Yorke ED, Wessels BW. Treatment planning for radio-immunotherapy.Phys Med Biol 41: 2009–2026, 1996.
Furhang EE, Sgouros G, Chui C-S. Radionuclide photon dose kernels for internal dosimetry.Med Phys 23: 759–764, 1996.
Sgouros G, Barest G, Thekkumthala J, Chui C, Mohan R, Bigler RE, et al. Treatment planning for internal radionuclide therapy: three-dimensional dosimetry for nonuniformly distributed radionuclides.J Nucl Med 31: 1884–1891, 1990.
Uchida I, Yamada Y, Oyamada H, Nomura E. Calculation algorithm of three-dimensional absorbed dose distribution due toin vivo administration of nuclides for radiotherapy.KAKU IGAKU (Jpn J Nucl Med) 29: 1299–1306, 1992. (in Japanese)
Giap HB, Macey DJ, Podoloff DA. Development of a SPECT-based three-dimensional treatment planning system for radioimmunotherapy.J Nucl Med 36: 1885–1894, 1995.
Furhang EE, Chui C-S, Sgouros G. A Monte Carlo approach to patient-specific dosimetry.Med Phys 23: 1523–1529, 1996.
Sipilä O, Nikkinen P, Pohjonen H, Poutanen V-P, Visa A, Savolainen S, et al. Accuracy of a Registration Procedure for Brain SPECT and MRI: Phantom and Simulation Studies.Nucl Med Commun 18: 517–526, 1997.
Pohjonen H, Nikkinen P, Sipila O, Launes J, Salli E, Salonen O, et al. Registration and display of brain SPECT and MRI using external markers.Neuroradiology 38: 108–114, 1996.
Pohjonen HK, Savolainen SE, Nikkinen PH, Poutanen VPO, Korppi-Tommola ET, Liewendahl BK. Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids.Ann Nucl Med 10: 409–417, 1996.
International Commission on Radiological Protection.Radiation Dose to Patients from Radiopharmaceuticals, Publication 53. Oxford, Pergamon Press, 1987
Press WH, Teukolsky SA, Vetterling WT, Flannery BP. Numerical Recipes in C:The Art of Scientific Computing, 2nd ed., Cambridge, Cambridge Press, pp. 496–536, 1992.
Browne E, Firestone RB, Shirley VS.Table of Radioactive Isotopes, New York, John Wiley and Sons, Inc., 1986.
Snyder WS, Ford MR, Warner GG, Fisher HL. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom.J Nucl Med: suppl. N3: 7–52, 1969.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lampinen, J.S., Pohjonen, H.K. & Savolainen, S.E. Calculating internal dose by convolution from SPECT/MR fusion images. Ann Nucl Med 12, 1–5 (1998). https://doi.org/10.1007/BF03165409
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03165409