Abstract
Objective: The purpose of this study was to compare a semi-quantitative approach to estimating glomerular filtration rate (GFR) by magnetic resonance imaging with radionuclide calculation of GFR, and to investigate whether spin echo or gradient echo is more suitable for estimating GFR.Methods and patients: Fourteen kidneys of seven patients (GFR ranging from 26 to 57 ml/min) were studied. Spin echo and gradient echo sequences interleaving each other at every excitation were used. After intravenous injection of gadopentetate dimeglumine, serial scans were performed. The signal intensities measured in the regions of interest were converted to time-transverse relaxation rate changes for both spin echo (ΔR2) and gradient echo (ΔR2*). The areas under the time-ΔR2 and time-ΔR2* curves were calculated as a semi-quantitative index of GFR for both spin echo and gradient echo images, and the results were compared by GFR measured by radionuclide imaging.Results: The semi-quantitative index of the GFR calculated from spin echo images showed a significant correlation with the GFR measured by radionuclide imaging (r=0.85,P<0.001). On the other hand, the semi-quantitative index of the GFR calculated from gradient echo images showed no such correlation (r=0.46,P=0.10).Conclusion: Spin echo sequences may be more suitable than gradient echo sequences for the evaluation of GFR.
Similar content being viewed by others
References
Dumoulin CL, Buonocore MH, Opsahl LR, Katzberg RW, Darrow RD, Morris TW, Batey C. Noninvasive measurement of renal hemodynamic functions using gadolinium enhanced magnetic resonance imaging. Magn Reson Med 1994;32:370–8.
Niendorf ER, Grist TM, Lee FT Jr, Brazy PC, Santyr GE. Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging. Radiology 1998;206:791–8.
Carvlin MJ, Arger PH, Kundel HL, Axel L, Dougherty L, Kassab EA, Moore B. Use of Gd-DTPA and fast gradient echo and spin echo MR imaging to demonstrate renal function in the rabbit. Radiology 1989;170:705–11.
Kikinis R, von Schulthess GK, Jäger P, Dürr R, Bino M, Kuoni W, Kübler O. Normal and hydronephrotic kidney: evaluation of renal function with contrast-enhanced MR imaging. Radiology 1987;165:837–42.
Choyke PL, Frank JA, Girton ME, Inscoe SW, Carvlin MJ, Black JL, Austin HA, Dwyer AJ. Dynamic Gd-DTPA-enhanced MR imaging of the kidney: experimental results. Radiology 1989;170:713–20.
Carvlin MJ, Arger PH, Kundel HL, Axel L, Dougherty L, Kassab EA, Moore B. Acute tubular necrosis: use of gadolinium-DTPA and fast MR imaging to evaluate renal function in the rabbit. J Comput Assist Tomogr 1987;11:488–95.
Semelka RC, Hricak H, Tomei E, Floth A, Stoller M. Obstructive nephropathy: evaluation with dynamic Gd-DTPA-enhanced MR imaging. Radiology 1990;175:797–803.
Watson AD, Rocklage SM, Carvlin MJ. Contrast agents. In: Stark DD, Bradley WG, editors. Magnetic Resonance Imaging, 2nd ed. St. Louis: Mosby Year Book, 1992:372–437.
Gates GF. Glomerular filtration rate: estimation from fraction renal accumulation of 99mTc-DTPA (Stannous). Am J Radiol 1982;138:565–70.
Rosen BR, Belliveau JW, Buchbinder BR, et al. Contrast agents and cerebral hemodynamics. Magn Reson Med 1991;19:285–92.
Weisskoff RM, Zuo CS, Boxerman JL, Rosen BR. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn Reson Med 1994;31:601–10.
Trillaud HH, Degreze P, Mesplede Y, Douws C, Palussiere J, Grenier N. Evaluation of experimentally induced renal hypoperfusion using iron oxide particles and fast magnetic resonance imaging. Acad Radiol 1995;2:293–9.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Uematsu, H., Matsuda, T., Tsuchida, T. et al. Semi-quantitative approach to estimating GFR by magnetic resonance imaging. MAGMA 10, 171–176 (2000). https://doi.org/10.1007/BF02590643
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02590643