Skip to main content
Log in

Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits

  • Imaging
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Laser Doppler imaging (LDI) is investigated as a novel method for in vivo ligament tissue blood flow determination. LDI output signal is obtained from surgically exposed rabbit medial collateral ligaments (MCL). The LDI signal, is compared with simultaneously determined, coloured microsphere (CM)-derived standardised MCL blood flow. Correlation of LDI output with the CM flow data and a linear regression of 17 data points in nine rabbits (joint injured to provoke an acute vascular response in the tissues) indicate that LDI provides a reasonable estimate of MCL blood flow, at least over the ranges assessed. If properly calibrated, and given enough tissue-specific data points, LDI may have advantages over conventional, but more invasive, techniques. The potential clinical application of LDI technology to joint injury and arthritis research is discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arnfield, M. R., Mathew, R. P. Tulip, J., andMcPhee, M. S. (1992): ‘Analysis of tissue optical coefficients using an approximate equation valid for comparable absorbtion and scattering’,Phys. Med. Biol.,37, pp. 1219–1230

    Article  Google Scholar 

  • B, N. J., Dougherty, G., andPettinger, S. J. (1990) ‘Comparative study of two laser Doppler blood flowmeters’,J. Mech. Eng. Technol.,14 pp. 243–249

    Google Scholar 

  • Bray, R., Doschak M., Tyberg, J. (1994): ‘Elevation of blood flow in an ACL-deficient rabbit knee is associated with deterioration of MCL biomechanical properties’,Proc. Can. Orthopaed. Res. Soc., Winnipeg, Manitoba, pp. 28–39

  • Butterwick, D., Paul, P., Bray, R., andTyberg, J. (1992): ‘Vascularity and blood flow in adult rabbit medial collateral and anterior cruciate ligaments’,Proc. Can. Orthopaed. Res. Soc.,26, p. 25

    Google Scholar 

  • Ferrell, W. R., Khoshbaten, A., andAngerson, W. J. (1990): ‘Responses of bone and joint blood vessels in cats and rabbits to electrical stimulation of the nerves supplying the knee’,J. Physiol.,431, pp. 677–687

    Google Scholar 

  • Heyman, M. A., Payne, B. D., Hoffman, J. I. E., andRudolph A. M. (1977): ‘Blood flow measurements with radionuclide-labelled particles’,Prog. Cardiovasc. Disc.,20, pp. 55–79

    Article  Google Scholar 

  • Kalbfleisch, J. G. (1985a): ‘Probability and statistical interference Vol. 1: Probability’ (Springer-Verlag, New York, USA) 2nd edn.

    Google Scholar 

  • Kalbfleisch, J. G. (1985b): ‘Probability and statistical interference Vol. 2: Statistical inference,’ (Springer-Verlag, New York, USA) 2nd edn.

    Google Scholar 

  • Karimian, S. M., McDougall, J. J., andFerrell, W. R. (1995): ‘Neuropeptidergic and autonomic control of the vasculature of the rat knee joint revealed by laser Doppler perfusion imaging’,Exp. Physiol.,80, pp. 341–348

    Google Scholar 

  • Kowalik, P., Schulz, R., Guth, B., Schade, A., Paffhausen, W., Gross, R., andHeusch, G. (1991): ‘Measurement of regional blood flow with multiple coloured microspheres’,Circ.,83, pp. 974–982

    Google Scholar 

  • Lindsberg, P.J., O'Neil, J.T., Paakkari, I.A., Hallenbeck, J.M., andFuerstein, G. (1989): ‘Validation of laser Doppler flowmetry in measurement of spinal cord blood flows’,Am. J. Physiol.,257, pp. H674-H680

    Google Scholar 

  • Nilsson G. E., Tenland, T., andOberg, P. A. (1990): ‘A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy’,IEEE Trans.,BME-27, pp. 597–604

    Google Scholar 

  • Nillson, G.E. (1984): ‘Signal processor for laser Doppler flowmeters,’Med. Biol. Eng. Comput.,22, pp. 343–348

    Article  Google Scholar 

  • Paul, P., Bray, R., andDoschak, M. (1994): ‘Joint position influences vascular filling patterns in adult anterior cruciate ligament’,Proc. Can. Orthopaed. Res. Soc., pp. 28–51

  • Shepherd, A. P., Riedel, G. L., Kiel, J. W., Haumschild, D. J., andMaxwell, L. C. (1987): ‘Evaluation of an infrared laser Doppler flowmeter’,Am. J. Physiol.,252, pp. G832-G839

    Google Scholar 

  • Smits, G. J., Roman, R. J., andLombard, J. H. (1986): ‘Evaluation of laser Doppler flowmetry as a measure of tissue blood flow’,J. Appl. Physiol.,61, pp. 666–672

    Google Scholar 

  • Stern, M. D. (1975): ‘In vivo evaluation of microcirculation by coherent light scattering’,Nature,254, pp. 56–58

    Article  Google Scholar 

  • Wårdell, K., Jakobsson, A., andNilsson, G. E. (1993): ‘Laser Doppler perfusion imaging by dynamic light scattering’,IEEE Trans.,BME-40, pp. 309–316

    Google Scholar 

  • Watkins, D., andHolloway, G. A. Jr. (1978): ‘96An instrument to measure cutaneous blood flow using the Doppler shift of laser light’ibid.,,BME-25, pp. 28–33

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bray, R., Forrester, K., McDougall, J.J. et al. Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits. Med. Biol. Eng. Comput. 34, 227–231 (1996). https://doi.org/10.1007/BF02520078

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02520078

Keywords

Navigation