Bleeding through the fiber interstices of a knitted Dacron graft 12 years after its implantation: Report of a case

  • Case Reports
  • Published:
Surgery Today Aims and scope Submit manuscript

Abstract

We present herein the case of a 65-year-old man who suddenly developed fresh perigraft bleeding into the space between a knitted Dacron bifurcated graft and the aneurysmal sac, 12 years after undergoing graft replacement. Intraoperative findings did not show Dacron fiber degeneration at the nonanastomotic sites or a pseudoaneurysm at the anastomotic site. Widened Dacron fiber interstices resulting from graft dilation without sufficient graft healing was thought to have caused delayed hemorrhage through the macroscopically intact graft material, followed by massive clot retention between the graft and the aneurysmal sac. This case report serves to demonstrate that careful long-term follow-up is essential for patients who have undergone vascular graft replacement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Nunn DB, Freeman MH, Hudgins PC (1979) Postoperative alterations in size of Dacron aortic grafts. An ultrasonic evaluation. Ann Surg 189:741–745

    Article  CAS  PubMed  Google Scholar 

  2. Nunn DB, Carter MM, Donohue MT, Hudgins PC (1990) Postoperative dilation of knitted Dacron aortic bifurcation graft. J Vasc Surg 12:291–297

    Article  CAS  PubMed  Google Scholar 

  3. Blumenberg RM, Gelfand ML, Barton EA, Bowers CA, Gittleman DA (1991) Clinical significance of aortic graft dilation. J Vasc Surg 14:175–180

    Article  CAS  PubMed  Google Scholar 

  4. Cooke PA, Nobis PA, Stoney RJ (1974) Dacron aortic graft failure, Arch Surg 108:101–103

    CAS  PubMed  Google Scholar 

  5. Trippestad A (1985) Late rupture of knitted Dacron double velour arterial prostheses. Acta Chir Scand 151:391–395

    CAS  PubMed  Google Scholar 

  6. Blumenberg RM, Gelfand ML (1977) Failure of knitted Dacron as an arterial prosthesis. Surgery 81:493–496

    CAS  PubMed  Google Scholar 

  7. Lundström ORS, Ängquist KA, Hallmans G (1976) Bilateral aneurysm of Dacron graft following aorto-femoral graft operation Acta Chir Scand 142:479–482

    PubMed  Google Scholar 

  8. Tutassaura H, Gerein AN, Sladen JG (1978) True aneurysms in prosthetic femoropopliteal grafts. Am Surg 44:262–266

    CAS  PubMed  Google Scholar 

  9. Kim GE, Imparato AM, Nathan I, Riles TS (1979) Dilation of synthetic grafts and junctional aneurysms. Arch Surg 114:1296–1303

    Google Scholar 

  10. Clagett GP, Salander JM, Eddleman WL, Cabellon S Jr, Youkey JR, Oslon DW, Hutton JE Jr, Rich NM (1983) Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysm: etiologic considerations. Surgery 93:9–16

    CAS  PubMed  Google Scholar 

  11. Ottinger LW, Darling RC, Wirthlin LS, Linton RR (1976) Failure of ultralightweight knitted Dacron grafts in arterial reconstruction. Arch Surg 111:146–149

    CAS  PubMed  Google Scholar 

  12. Berger K, Sauvage LR (1981) Late fiber deterioration in Dacron arterial grafts. Ann Surg 193:477–491

    CAS  PubMed  Google Scholar 

  13. Berger K, Sauvage LR, Rao AM, Wood SJ (1972) Healing of arterial prostheses in man: its incompleteness. Ann Surg 175:118–127

    Article  CAS  PubMed  Google Scholar 

  14. Sauvage LR (1989) Biologic behavior of grafts in arterial system. In: Haimovici H (ed) Vascular surgery. Principles and techniques. Appleton & Lange, Connecticut, pp 136–160

    Google Scholar 

  15. Sauvage LR, Berger K, Wood SJ, Nakagawa Y, Mansfield PB (1971) An external velour surface for porous arterial prostheses. Surgery 70:940–953

    CAS  PubMed  Google Scholar 

  16. Swartbol P, Albrechtsson U, Pärsson H, Norgren L (1996) Dilation of aorto-bifemoral knitted Dacron grafts after a mean implantation of 5 years. Int Angiol 15:236–239

    CAS  PubMed  Google Scholar 

  17. Nunn DB, Carter MM, Donohue MT, Pourdeyhimi B (1996) Dilative characteristics of Microvel and Vascular-II aortic bifurcation grafts. J Biomed Mater Res 30:41–46

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Akiyama, K., Takazawa, A., Hirota, J. et al. Bleeding through the fiber interstices of a knitted Dacron graft 12 years after its implantation: Report of a case. Surg Today 29, 953–956 (1999). https://doi.org/10.1007/BF02482795

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02482795

Key Words

Navigation