Noninvasive automatic determination of mean arterial pressure

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A new instrument for the indirect noninvasive measurement of mean arterial pressure (m.a.p.) has been constructed and evaluated in man. The instrument does not require an external microphone or transducer and determines m.a.p. rather than systolic and diastolic pressure. Instead, the method employs the point of maximal oscillations as an indicator of m.a.p. The instrument automatically inflates a standard blood pressure cuff and determines the m.a.p. by measuring the cuff pressure oscillations as the cuff pressure is reduced by discrete increments. Cuff deflation in discrete increments, instead of continuously, allows the oscillation data obtained at each cuff pressure to be tested for artefacts and averaged, greatly enhancing artefact-rejection ability. The m.a.p. is selected as the lowest cuff pressure at which the oscillation amplitude is a maximum. The instrument was tested on the bicep and ankle in a series of 28 studies involving 17 human subjects with intra-arterial catheters. Averaging the mean errors from each of the 28 studies, there was an overall mean error of — 0·23 mmHg, with a standard deviation of 4·21 mmHg. The correlation coefficient was 0·98. The instrument was found to give good results in a wide variety of clinical subjects and physiologic states.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Buggs, H., Johnson, P. E., Gordon, L. S., Balguma, F. B. andWettach, G. E. (1973) Comparison of systolic arterial blood pressure by transcutaneous doppler probe and conventional methods in hypotensive patients.Anesthesia & Analgesia,52, 776–778.

    Google Scholar 

  • Cohn, J. N. (1967) Blood pressure measurement in shock.J. AMA,199, 118–122.

    Google Scholar 

  • Collins, V. J. andMagora, F. (1963) Sphygmomanometry: the indirect measurement of blood pressure.Anesthesia & Analgesia,42, 443–452.

    Google Scholar 

  • Geddes, L. A., Moore, A. G., Garner, H., Rosborough, J., Ross, J. andAmend, J. (1970) The indirect measurement of mean blood pressure in the horse.The Southwestern Veterinarian,23, 289–294.

    Google Scholar 

  • Geddes, L. A., Chaffee, V., Whistler, S. J., Bourland, J. D. andTacker, W. A. (1977) Indirect mean blood pressure on the anesthetized pony.Amer. J. Vet. Res.,38, 2055–2057.

    Google Scholar 

  • Kirby, R. R., Kemmerer, W. T. andMorgan, J. L. (1969) Transcutaneous doppler measurement of blood pressure.Anesthesiology,31, 86–89.

    Google Scholar 

  • Posey, J. A., Geddes, L. A., Williams, H. andMoore, A. G. (1969) The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure.Cardiovascular Research Center Bull.,8, 15–25.

    Google Scholar 

  • Simpson, J. A., Jamieson, G., Dickhaus, D. W. andGrover, R. F. (1965) Effect of size of cuff bladder on accuracy of measurement of indirect blood pressure.Amer. Heart J.,70, 208–215.

    Article  Google Scholar 

  • Van Bergen, F. H., Weatherhead, D. S., Treloar, A. E., Dobkin, A. B. andBuckley, J. J. (1954) Comparison of indirect and direct methods of measuring arterial blood pressure.Circulation,10, 481–490.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ramsey, M. Noninvasive automatic determination of mean arterial pressure. Med. Biol. Eng. Comput. 17, 11–18 (1979). https://doi.org/10.1007/BF02440948

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02440948

Keywords

Navigation