Abstract
Extracorporeal circulation with a membrane oxygenator (ECMO) was used in 11 patients with acute respiratory insufficiency who did not respond to conventional treatment. By pass was veno-arterial in every case, seven times with femoral artery return, three times with axillary artery return, and once with both femoral and axillary return. Five patients died on ECMO. Six patients were taken off ECMO and two of them are long-term survivors. In nine cases ECMO allowed short-term control of respiratory failure. The respective roles of oxygen supply from ECMO and the haemodynamic changes incurred by its use are discussed. Although use of ECMO for long periods seems less hazardous now, present results are restricted by the lack of therapy for the underlying pulmonary lesions.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bartlett, R.H., Gazzaniga, A.G., Fong, S.W., Burn, N.E.: Prolonged extracorporeal cardiopulmonary support in man. J. Thorac. Cardiovasc. Surg.68, 918 (1974)
Gille, J.P.: L'assistance respiratoire par circulation extracorporelle avec poumon artificiel à membrane. Bull. Physio. Path. Res.10, 373 (1974)
Goulon, M., Gajdos, Ph., Raphael, J.C.: Indications actuelles de l'assistance respiratoire par oxygénator à membrane. Nouv. Presse Méd3, 1791 (1974)
Goulon, M., Gajdos, Ph., Raphael, J.C., Barois, A., Nouailhat, F., Grosbuis, S., Babinet, P., Dequirot, A., Schortgen, G.: Traitement de l'insuffisance respiratoire aigüe réfractaire par oxygénateur à membrane. Guérison de deux malades. Nouv. Presse Med.3, 1795 (1974).
Hattersley, P.G.: Activated coagulation time of whole blood. J. Am. Med. Assoc.196, 436 (1966)
Hill, J.D.: Extracorporeal oxygenation for acute respiratory insufficiency. Clinical experience. Mt. Sinai. J. Med. NY40, 189 (1973)
Hill, J.D., Ratliff, J.L., Fallat, R.J., Tucker, H.J., Lamy, H., Dietrich, H.P., Gerbode, F.: Prognostic factors in the treatment of acute respiratory insufficiency with longterm extracorporeal oxygenation. J. Thorac. Cardiovasc. Surg.68, 905 (1974)
Hanson, E.L., Drinker, P.A., Don, H.F., Van Devanter, S.H., Bonnet-Eymar, J., Moore, F.D.: Venoarterial by-pass with a membrane oxygenator: successful respiratory support in a woman following haemorrhage secondary to renal failure. Surgery75, 557 (1974)
Lemaire, F., Teissere, B., Harari, A., Loisance, D.: La PaO2 en oxygène pur est-elle un critère fiable de transfer pulmonaire au cours des assistances respiratoires par poumon à membrane? Nouv. Presse Med.3, 1815 (1974)
Sausse, A., Granger, A., Lissot, J.: La machine de suppléance cardio-pulmonaire R. P.: Description technique et performances pratiques. In: Réanimation et médicine d'urgence Goulon, M., Rapin, M. (eds.), p. 191. Paris: Expansion Scientifique 1973
Zapol, W.M., Qvist, J., Pontopiddan, H., Liland, A., Mc Enary, T., Laver, M.B.: Extracorporeal perfusion for acute respiratory failure. Recent experiences with the spiral coil membrane lung. J. Thorac. Cardiovasc. Surg.69, 439 (1975)