Summary
Somatosensory evoked potentials (SEPs) were monitored in the course of 368 carotid endarterectomies (CEAs) carried out in 312 patients. In an initial group of 26 patients the shunt was used routinely while in a second group, involving 342 CEAs, it was applied selectively on the basis of modifications which the SEP underwent during clamping. The criterion for shunting was the progressive reduction, up to 50%, of the N20-P25 amplitude. New postoperative neurological deficits appeared in 6 patients, all of whom displayed a transitory SEP flattening. The SEPs of 2 of these returned to normal by the time they awoke and both showed a clinical deficit homolateral to the operated side. In only 2 cases did the deficit fail to regress completely and their postoperative CT scans revealed ischaemic lesions. A positive relationship emerged between SEP changes and back pressure values; nonetheless, as many as 75% of the patients with low residual back pressure values (< 25 mm Hg) tolerated the clamping. SEP monitoring appears to provide a reliable basis for selectively applying a shunt when there is a high risk of haemodynamic ischaemia during clamping.
Similar content being viewed by others
References
Ackerstaff RGA, Krul JMJ, Eikelboom BC, Vermeulen FEE (1990) Automatic EEG monitoring and stroke detection during carotid endarterectomy. Neurophysiol Clin 20: S23
Astrup J (1981) Energy-requiring cell functions in the ischemic brain: their critical supply and possible inhibition in protective therapy. J Neurosurg 54:482–497
Astrup J, Siejo BK, Symon L (1981) Threshold in cerebral ischemia — the ischemic penumbra. Stroke 12:723–725
Beven EG (1975) Carotid endarterectomy. Surg Clin North Am 55:1111–1124
Blume WT, Ferguson GG, McNeill DK (1986) Significance of EEG changes at carotid endarterectomy. Stroke 17:891–897
Boysen G (1971) Cerebral blood flow measurement as a safeguard during carotid endarterectomy. Stroke 2:1–10
Branston NM, Symon L, Crockard HA, Pasztor E (1974) Relationship between the cortical evoked potentials and local cortical blood flow following acute middle cerebral occlusion in the baboon. Exp Neurol 45:195–208
Chiappa KH, Burke SR, Young RR (1979) Results of electroencephalographic monitoring during 367 carotid endarterectomies. Stroke 10:381–388
Collice M, Arena O, Fontana RA, Mola M, Galbiati N (1986) Role of EEG monitoring and cross-clamping duration in carotid endarterectomy. J Neurosurg 65:815–819
Connolly JE, Kwann JHM, Stemmer EA (1977) Improved results with carotid endarterectomy. Ann Surg 186:334–342
De Scisciolo G, Amantini A, Ronchi O, Bartelli M, Peduto A, Paci C, Pratesi C, Alessi A, Pinto F (1988) SEP monitoring during carotid surgery. In: Grundy BL, Villani RM (eds) Evoked potentials. Springer, Wien NewYork, pp 121–127
De Vleschauwer P, Horsch S, Haupt WF, Huber P (1985) The use of somatosensory evoked responses in carotid surgery for monitoring brain function. Acta Chir Belg 85:293–298
Fava E, Ducati A, Bortolani E, Miani S (1990) Role of SEP monitoring in selection of patients requiring temporary shunting in carotid endarterectomy. Neurophysiol Clin 20:S22
Ferguson GG (1982) Intra-operative monitoring and internal shunt: are they necessary in carotid endarterectomy? Stroke 13:287–289
Gigli GL, Caramia M, Marciani MG, Zarola F, Iavaroni F, Rossini PM (1987) Monitoring of subcortical and cortical evoked potentials during carotid endarterectomy: comparison with stump pressure levels. Electroencephalogr Clin Neurophysiol 68:424–432
Grundy BL (1983) Intraoperative monitoring of sensory evoked potentials. Anesthesiology 58:72–87
Hunter G, Sieffert G, Malone J, Moore GS (1981) The accuracy of carotid back pressure as a guide for operative management for carotid endarterectomy. Surgery 13:319–326
Markand ON, Dilley RS, Morthy SS, Warren C (1984) Monitoring of somatosensory evoked responses during carotid endarterectomy. Anesthesiolog 41:375–378
Matsumoto GH, Baker JD, Watson CW, Gleucklich B, Callow AD (1976) EEG surveillance as a means of extending operability in high risk carotid endarterectomy. Stroke 7:554–559
McKey R, Dundt T, Mickenfelder J, Gronert T, Messick J, Sharborough F, Piepgrass D (1976) Internal carotid artery stump pressure and cerebral blood flow during carotid endarterectomy. Anesthesiology 45:390–399
McPherson AW, Zeger S, Traystman RJ (1986) Cerebral oxygen consumption during hypoxic hypoxia in dogs. Stroke 17:30–36
McPherson RW, Sell B, Traystman RJ (1986) Effects of thiopental, fentanyl end etomidate on upper extremity somatosensory evoked potentials in humans. Anesthesiology 65:584–589
Mola M, Collice M, Levati A (1986) Continuous intraoperative electroencephalographic monitoring in carotid endarterectomy. Eur Neurol 25:53–60
Moore WS, Yee JM, Hall AD (1973) Collateral cerebral blood pressure: an index of tolerance to temporary carotid occlusion. Arch Surg 106:520–523
Ojemann RG, Heros RC (1986) Carotid endarterectomy. To shunt or not to shunt? Arch Neurol 43:617–618
Pinto F, Ragazzoni A, Amantini A, Scisciolo G de, Bartelli M, Rossi R, Pieraccioli E (1990) Anesthetic induction with thiopental: its effect on scalp topography of median nerve somatosensory evoked potential. Acta Anesthesiol Scand 34:389–392
Russ W, Fraedrich G, Hehrlein FW, Hempelmann G (1985) Intraoperative somatosensory evoked potentials as a prognostic factor of neurologic state after carotid endarterectomy. Thorac Cardiovasc Surg 33:392–396
Spetzler RF, Nehls DG, Awad IA (1990) Vascular surgery of cerebral ischemia and infarction. In: Vinken PJ, Bruyn GW, Klawans HL (eds) Handbook of clinical neurology, revised series 9: vascular diseases, part 1. Elsevier, Amsterdam, p 447
Sundt TM, Sharbrough FW, Piepgrass DG, Kearns TP, Messick GM, O'Fallon W (1981) Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy. Mayo Clin Proc 56:533–543
Symon L, Wang AD, Costa e Silva IE, Gentili F (1984) Perioperative use of somatosensory evoked responses in aneurysm surgery. J Neurosurg 60:269–275
Symon L, Wang AD, Rosestein J, Branston N, Tsutsui T (1985) Effect of brain ischemia on evoked electrical activity in man. J Cereb Flow Metab 5:S37-S38
Thompson JE (1979) Complications of carotid endarterectomy and their prevention. World J Surg 3:155–165
Trazzi R, Massei R, Lubatti L, Bortolani E, Fava E, Landi A, Cenzato M, Ducati A (1985) Valutazioni neurologiche in anestesia e rianimazione. Minerva Anestesiol 51:243–251
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Amantini, A., Bartellil, M., de Scisciolo, G. et al. Monitoring of somatosensory evoked potentials during carotid endarterectomy. J Neurol 239, 241–247 (1992). https://doi.org/10.1007/BF00810344
Received:
Revised:
Accepted:
Issue Date: