Abstract
The biomechanical stability of two compound osteosynthesis techniques with and without intramedullary splinting were compared in 20 paired cadaver femora. Group A was stabilised using a contoured 12-hole DC plate and polymethylmethacrylate cement. In group B an additional intramedullary semi-diameter osteosynthesis plate was inserted parallel to the outer plate and transfixed with the same screws. The specimens were tested in a universal testing machine using a force applied to the specimen at 45° to the load to provoke the most unfavourable condition, consisting of a bending moment and torsion. Both force and extension were recorded. The compound osteosynthesis with an additional intramedullary plate (group B) reached an average higher load stability. This increase of stability was not significant statistically.
Similar content being viewed by others
References
Andersen JT, Erickson JM, Thompson RC, Chao EY (1978) Pathological femoral shaft fractures comparing fixation techniques using cement. Clin Orthop 131:273–278
Charnley J (1960) Anchorage of the femoral head prosthesis to the shaft of the femur. J Bone Joint Surg [Br] 42:28–30
Ganz R, Isler B, Mast J (1984) Internal fixation technique in pathological fractures of the femur. Arch Orthop Trauma Surg 103:73–80
Hubbard MJS (1973) The fixation of experimental femoral shaft torque fractures. Acta Orthop Scand 44:55–61
Leggon RE, Lindsey RW, Panjabi MM (1988) Strength reduction and the effects of treatment of long bones with diaphyseal defects involving 50% of the cortex. J Orthop Res 6:540–546
Lintner P, Burri C, Claes L, Plank E, Rüter A (1978) Stabilitätsverhalten und Implantatbeanspruchung von Platten- und Verbundosteosynthesen des Femurschaftes. Aktuel Traumatol 8:435–440
Mensch JS, Markolf KL, Roberts SB, Finerman GM (1976) Experimental stabilisation of segmental defects in the human femur. J Bone Joint Surg [Am] 58:185–190
Miller GJ, Griend RA van den, Blake WP, Springfield DS (1987) Performance evaluation of a cement-augmented intramedullar fixation system for pathologic lesions of the femoral shaft. Clin Orthop 221:246–253
Müller ME (1962) Die Verwendung von Kunstharzen in der Knochenchirurgie. Arch Orthop Unfall Chir 54:513–522
Savvidis E, Löer F (1989) Zur Operationstechnik bei der Femurschaftfensterung im Rahmen von Revisions-Operationen nach Hüftgelenk-Totalendoprothesen. Z Orthop 127:228–236
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Heller, K.D., Zilkens, K.W., Cohen, B. et al. Compound osteosynthesis of pathological fractures of the proximal femoral shaft. Arch Orthop Trauma Surg 115, 115–117 (1996). https://doi.org/10.1007/BF00573454
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00573454