Residual silicone detection using mri following previous breast implant removal: Case reports

  • Published:
Aesthetic Plastic Surgery Aims and scope Submit manuscript

Abstract

The current controversy surrounding the safety of silicone gel breast implants has resulted in an increasing number being removed. Although previous reports have suggested that remnants of the implant capsule are reabsorbed after explantation surgery, the persistence of the capsule in fact may be associated with implant fragments and silicone gel leakage. In this study we have used magnetic resonance imaging (MRI) to identify residual silicone gel and silicone granulomas following the removal of silicone gel breast implants. Four representative clinical case reports are presented. These patients, who had residual silicone present in their bodies, presented to us with breast pain, palpable masses, or abnormal calcific mass densities apparent on a mammogram. High-resolution MRI images were found to be helpful in identifying local and remote collections of silicone gel, silicone granulomas, and residual capsules that were incompletely removed from previous explantation surgery. MRI breast images demonstrated high resolution and provided the accurate anatomical locations of residual silicone gel and silicone granulomas in all the regions of breast parenchyma, chest wall muscles, and axillae. Patients with persistent local symptoms following explantation surgery may benefit from an evaluation of the breast using MRI.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Alm CY, Shaw W, Narayanan K, et al: Definitive diagnosis of breast implant rupture using M.R.I. (Magnetic Resonance Imaging). Plast Reconstr Surg 90:1, 1992

    Google Scholar 

  2. Baldwin CM, Kaplan EN: Silicone-induced human adjuvant disease? Ann Plast Surg 10:270, 1983

    Google Scholar 

  3. Foster WC, Springfield DS, Brown KLB: Pseudotumor of the arm associated with rupture of silicone-gel breast prosthesis J Bone Joint Surg65:48, 1983

    Google Scholar 

  4. Schneider E, Chan TW: Selective MR imaging of silicone with the three-point Dixon technique. Radiology 187:89, 1993

    Google Scholar 

  5. Sergott TJ, Limoli JP, Baldwin CM, Laub DR: Human adjuvant disease, possible autoimmune disease silicone implantation: a review of the literature, case studies, and speculation for the future. Plast Reconstr Surg 78:104, 1986

    Google Scholar 

  6. Spiera H: Scleroderma after silicone augmentation mammoplasty. J Am Med Assoc 260:236, 1988

    Google Scholar 

  7. Uretsky BF, O'Brien J, Courtiss EH, Becker MD: Augmentation mammoplasty associated with severe systemic illness. Ann Plast Surg 3:445, 1979

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ahn, C.Y., Shaw, W.W., Narayanan, K. et al. Residual silicone detection using mri following previous breast implant removal: Case reports. Aesth. Plast. Surg. 19, 361–367 (1995). https://doi.org/10.1007/BF00451663

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00451663

Key words

Navigation