Skip to main content

Advertisement

Log in

The 15O continuous-inhalation method: Correction for intravascular signal using C15O

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Cerebral oxygen metabolism (CMRO2) and fractional extraction (OEF) regional values obtained using the 15O steady-state method and positron-emission tomography (PET) were corrected for the activity remaining in blood vessels (a source of overestimation of the OEF neglected in the simple steady-state model) using an additional scan during continuous inhalation of nontoxic amounts of carbon monoxide labeled with 15O (C15O). The method was applied to ten serial PET studies. In normal tissue, OEF overestimation was 11%±2.6% and 9%±2.0% in gray and white matter, respectively. In pathological tissue, the OEF overestimation was, on average, higher than in normal tissue (28%±17% in the core of lesions), but more variable. In both normal and abnormal tissue, however, it was found that (1) the lower the real OEF, the larger the correction applied, and (2) the correction appears to be particularly necessary in situations of abnormally low OEF. The use of C15O continuous inhalation is a simple, direct, and accurate method for blood-activity correction when the 15O steady-state technique is employed to study pathophysiology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ackerman RH, Correia JA, Alpert NM, Baron JC, Gouliamos A, Grotta JC, Brownell GL, Taveras JM (1981) Positron imaging in ischemic stroke disease using compounds labeled with oxygen 15. Arch Neurol 38:537–543

    Google Scholar 

  • Baron JC, Steinling M, Tanaka T, Cavalheiro E, Soussaline F, Collard P (1981) Quantitative measurement of CBF, oxygen extraction fraction (OEF) and CMRO2 with the 15O continuous inhalation technique: experimental evidence and normal values in man. J Cereb Blood Flow Metab 1 (suppl 1):S5-S6

    Google Scholar 

  • Baron JC, Bousser MG, Comar D, Rougemont D, Lebrun-Grandié P, Castaigne P (1983) Apport de la tomographie par émission de positons dans l'étude physiopathologique de l'ischémie cérébrale chez l'homme. La Presse Medicale 12:3066–3072

    Google Scholar 

  • Bigler RE, Sgouros G (1983) Biological analysis and dosimetry for 15O-labeled O2, CO2 and CO gases administered continuously be inhalation. J Nucl Med 24:431–437

    Google Scholar 

  • Chinn HI (1949) Carbon monoxide-hemoglobin levels of workers employed in airplane engine repair shops. J Ind Hyg Toxicol 31:258–260

    Google Scholar 

  • Frackowiak RSJ, Wise RSJ (1983) Positron tomography in ischemic cerebrovascular disease. Neurol Clin 1:183–200

    Google Scholar 

  • Frackowiak RSJ, Lenzi GL, Jones T, Heather JD (1980) Quantitative measurement of regional cerebral blood flow and oxygen metabolism in man, using 15O and positron emission tomography: theory, procedure and normal values. J Comput Assist Tomogr 4:727–736

    Google Scholar 

  • Jones T, Chesler DA, Ter-Pogossian M (1976) The continuous inhalation of oxygen-15 for assessing regional oxygen extraction in the brain of man. Br J Radiol 49:339–343

    Google Scholar 

  • Lammertsma AA, Jones T (1983) Correction for the presence of intravascular oxygen-15 in the steady state technique for measuring regional oxygen extraction ratio in the brain. 1. Description of the method. J Cereb Blood Flow Metab 3:416–424

    Google Scholar 

  • Lammertsma AA, Jones T, Frackowiak RSJ, Lenzi GL (1981) A theoretical study of the steady-state model for measuring cerebral blood flow and oxygen-15. J Comput Assist Tomogr 5:544–550

    Google Scholar 

  • Lammertsma AA, Wise RSJ, Heather JD, Gibbs JM, Leenders KL, Frackowiak RSJ, Rhodes CG, Jones T (1983) Correction for the presence of intravascular Oxygen-15 in the steady state technique for measuring regional oxygen extraction ratio in the brain. 2. Results in normal subjects and brain tumour and stroke patients. J Cereb Blood Flow Metab 3:425–431

    Google Scholar 

  • Lebrun-Grandié P, Baron JC, Soussaline F, Loc'h C, Sastre J, Bousser MG (1983) Coupling between cerebral blood flow and oxygen utilization in the normal human brain. Arch Neurol 40:230–236

    Google Scholar 

  • Phelps ME, Huang SC, Hoffman EJ, Kuhl DE (1979) Validation of tomographic measurement of cerebral blood volume with C-11-labelled carboxyhemoglobin. J Nucl Med 20:328–334

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pantano, P., Baron, JC., Crouzel, C. et al. The 15O continuous-inhalation method: Correction for intravascular signal using C15O. Eur J Nucl Med 10, 387–391 (1985). https://doi.org/10.1007/BF00256576

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00256576

Key words

Navigation