Abstract
The Pitzer method was used to calculate the pH values on the conventional and “true” scales for the TRIS—TRIS·HCl−NaCl−H2O buffer system in the 0–40 °C temperature region and 0–4 NaCl molality interval. This buffer can be used as a standard for pH measurements in a wide range of ionic strengths. The conventional scale is used in cells without a salt bridge. The “true” scale is recommended for pH measurements using cells with a salt bridge. At the same concentrations of the buffer solution, the “true” scale is essentially transformed into the scale of the National Bureau of Standards (NBS) of the USA.
Similar content being viewed by others
References
R. G. Bates,Determination of pH. Theory and Practice, J. Wiley and Sons, New York-London-Sydney, 1964.
V. V. Aleksandrov, D. K. Kollerov, and I. L. Skorik, inTrudy komiteta standartov mer i izmeritel'nykh priborov pri Sovete Ministrov SSSR [Works of the Committee of Standards, Measures, and Measuring Devices of the Council of Ministers of the USSSR], Standartgiz, Moscow-Leningrad, 1963, No. 68 (128), p. 34 (in Russian).
P. Ya. Tishchenko, A. S. Bychkov, G. Yu. Pavlova, and R. V. Chichkin,Zh. Fiz. Khim., 1998,72, 1049 [Russ. J. Phys. Chem., 1998,72 (Engl. Transl.)].
I. Hansson,Deep-Sea Res., 1973,20, 479.
M. Whitfield, R. A. Butler, and A. K. Covington,Oceanologica Acta, 1985,8, 423.
K. S. Pitzer,Report to a Group at the National Institute of Standards and Technology, December, 1988.
K. G. Knauss, T. J. Wolery, and K. J. Jackson,Geochim. Cosmochim. Acta, 1990,54, 1519.
R. E. Mesmer and H. F. Holms,J. Soln. Chem., 1992,21, 725.
A. K. Covington and M. I. Ferra,J. Soln. Chem., 1994,23, 1.
C.-Y. Chan, Y.-W. Eng, and K.-S. Eu,J. Chem. Eng. Data, 1995,40, 685.
K. S. Pitzer, inActivity Coefficients in Electrolyte Solutions, 2nd Ed., CRC Press, Boca Raton, Ann Arbor, Boston, London, 1991, p. 75.
P. Ya. Tishchenko,Izv. Akad. Nauk, Ser. Khim., 2000, 670 [Russ. Chem. Bull., 2000,49, 674 (Engl. Transl.)].
A. K. Covington,Anal. Chim. Acta, 1981,127, 1.
R. G. Bates and E. A. Guggenheim,Pure Appl. Chem., 1961,1, 163.
R. A. Durst and B. R. Staples,Clinic. Chem., 1972,18, 206.
R. G. Bates and R. A. Robinson,Anal. Chem., 1973,45, 420.
Author information
Authors and Affiliations
Additional information
Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 4, pp. 676–680, April, 2000.
Rights and permissions
About this article
Cite this article
Tishchenko, P.Y. Standardization of pH measurements based on the ion interaction approach. Russ Chem Bull 49, 680–684 (2000). https://doi.org/10.1007/BF02495481
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF02495481