Abstract
Bodymarkers are used to label the location and orientation of the transducer during ultrasound examination. We attempt to evaluate the usefulness of a new system that indicates transducer location over that of the conventional bodymarker. The proposed system uses an electromagnetic tracking device to track the three-dimensional (3-D) position and orientation of a small electromagnetic receiver attached to the ultrasound transducer relative to a transmitter placed under the bed. The new bodymarker is displayed as a 3-D graphic model. The physique of the examinee is calibrated by representing five locations on the body on the original bodymarker. To evaluate the accuracy of the system visually, we compared the transducer position indicated in the new bodymarker and the actual transducer position in four abdominal sections. Actual and displayed position and orientation closely agreed in all cases, and the transducer position indicator in the bodymarker display moved smoothly. Automatic transducer locator on the virtual 3-D bodymarker accurately indicated its position and orientation. This system is useful and convenient in clinical examinations.
Similar content being viewed by others
References
Hughes SW, D'Arcy TJ, Maxwell DJ, et al: Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor. Ultrasound in Med & Biol 1996;22: 957–968.
Rohling RN, Gee AH, Berman L: Automatic registration of 3-D ultrasound images. Ultrasound in Med & Biol 1998;24: 841–854.
Detmer PR, Bashein G, Hodges T, et al: 3D ultrasonic image feature localization based on magnetic scanning: in vitro calibration and validation. Ultrasound in Med & Biol 1994;9: 923–936.
Moon WK, Noh DY, Im JG: Multifocal, multicentric, and contralateral breast cancers: bilateral whole-breast US in the preoperative evaluation of patients. Radiology 2002;224: 569–576.
Kaplan SS: Clinical utility of bilateral whole breast US in the evaluation of women with dense breast tissue. Radiology 2001;221: 641–649.
Muratore DM, Galloway RL: Beam calibration without a phantom for creating a 3-D freehand ultrasound. Ultrasound in Med & Biol 2001;27: 1557–1566.
Barratt DC, Davies AH, Hughes AD, et al: Optimization and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries. Ultrasound in Med & Biol 2001;27: 957–968.
Tuomola PM, Gee AH, Prager RW, et al: Body-centered visualization for freehand 3-D. Ultrasound in Med & Biol 2000;26: 539–550.
Author information
Authors and Affiliations
About this article
Cite this article
Taniguchi, N., Kuwata, T., Ono, T. et al. Automatic virtual transducer locating system to assist in interpreting ultrasound imaging. J Med Ultrasonics 30, 211–216 (2003). https://doi.org/10.1007/BF02481283
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02481283