Summary
A new method of transvenous catheter closure has been developed for closure of a persistent ductus arteriosus (PDA), especially in infants and children. The device consists of a 5F or 6F triple-lumen catheter which carries a detachable silicone double-balloon at the tip. After expanding the distal positioning balloon, the proximal occlusion balloon is placed in the PDA and filled to the required size with radiopaque silicone. As the silicone cures inside the balloon, a solid plug occludes the PDA after it is detached from the catheter.
In 21 beagles a short segment of subclavian artery was interposed between the main pulmonary artery and the descending aorta, simulating a PDA. The procedure was tested on these models and proved to be suitable. Within one month the plug was covered with fibrous tissue at the pulmonary and aortic ends, thus ensuring permanent occlusion. The long-term follow-up extended for up to two years and confirmed the biocompatibility of the silicone plug.
Similar content being viewed by others
References
Athanasoulis CA (1980) Therapeutic applications of angiography, part 1.N Engl J Med 302:1117–1125
Bailey LL, Freedom RM, Fowler RF, Trusler GA (1976) Nonoperative management of late failure of a Glenn anastomosis.J Thorac Cardiovasc Surg 71:371–375
Berenstein A, Kricheff II (1979) Catheter and material selection for transarterial embolization: technical considerations. II. Materials.Radiology 132:631–639
Courtney JM, Gilchrist T (1980) Silicone rubber and natural rubber as biomaterials.Med Biol Eng Comput 18:538–540
Debrun G, Lacour P, Caron JP, Hurth M, Comoy J, Keravel Y, Laborit G (1975) Experimental approach to the treatment of carotid cavernous fistulas with an inflatable and isolated balloon.Neuroradiology 9:9–12
Debrun G, Lacour P, Caron JP, Kerave Y, Comey J, Louisance D (1975) Treatment of arterio-venous fistulas and aneurysms with an inflatable released balloon: experimental work-application in man. In: Salomon G (ed)Advances in cerebral angiography. INSERM Symposium, Marseille 1975. Springer, Berlin, pp 198–205
Forbes CD, Prentice CRM (1978) Thrombus formation and artificial surfaces.Br Med Bull 34:201–207
Grinnell VS, Hieshima GB, Mehringer CM, Fong Tsai, Shaw S, Irwin RJ (1981) Therapeutic renal artery occlusion with a detachable balloon.J Urol 126:233–237
Grinnell VS, Mehringer CM, Hieshima GB, Stanley P, Lurie PR (1982) Transaortic occlusion of collateral arteries to the lung by detachable valved balloons in a patient with tetralogy of fallot.Circulation 65:1276–1278
Hilal SK, Sane P, Michelson WJ, Kossein A (1978) The embolization of vascular malformations of the spinal cord with low viscosity silicone rubber.Neuroradiology 16:430–433
Hieshima GB, Grinnell VS, Mehringer CM (1981) A detachable balloon for therapeutic transcatheter occlusions.Radiology 138:227–228
Hunter JA, Sessions R, Buenger R (1970) Experimental balloon obstruction of the inferior vena cava.Ann Surg 171:315–320
Hunter JA, Dye WS, Javid H, Najafi H, Goldin M, Serry C (1977) Permanent transvenous balloon occlusion of the inferior vena cava.Ann Surg 186:491–498
Kaufmann SL, Strandberg JD, Barth KH, Gross GS, White RI (1979) Therapeutic embolization with detachable silicone balloons: long term effects in swine.Invest Radiol 14:156–161
Kitamura S, Sato K, Naito Y, Shimizu Y, Fujino M, Oyama C, Nakano S, Kawashima Y (1976) Plug closure of patent ductus arteriosus by transfemoral catheter method.Chest 70:631–635
Laks H, Hammond G, Geha AS (1981) Use of silicone rubber as a pericardial substitute to facilitate reoperation in cardiac surgery.J Thorac Cardiovasc Surg 82:88–92
Leslie J, Lindsay W, Amplatz K (1977) Nonsurgical closure of patent ductus arteriosus: an experimental study.Invest Radiol 12:142–145
Miller FJ, Rankin RS, Gliedmann JB, Nakashima E (1978) Experimental internal iliac artery embolization: evaluation of low viscosity silicone rubber, isobutyl-2-cyanoacrylate and carbon microspheres.Radiology 129:51–58
Mills NL, King TD (1976) Nonoperative closure of left-to-right shunts.J Thorac Cardiovasc Surg 72:371–378
Pevsner PH (1977) Mikro-balloon catheter for superselective angiography and therapeutic occlusion.Am J Roentgenol 128:225–230
Portsmann W, Wierny L, Warnke H (1967) Der Verschluss des Ductus arteriosus persistens ohne Thorakotomie (vorläufige Mitteilung).Thoraxchirurgie 15:199–203
Portsmann W, Wierny L, Warnke H (1968) Der Verschlussdes Ductus arteriosus persistens ohne Thorakotomie (zweite Mitteilung).Fortschr Rontgenstr 109:133–148
Portsmann W, Wierny L, Warnke H, Gerstberger G, Romaniuk PA (1971) Catheter closure of patent ductus arteriosus.Radiol Clin North Am 9:203–218
Rashkind WJ, Cuaso CC (1979) Transcatheter closure of patent ductus arteriosus.Pediatr Cardiol 1:3–7
Rees TD, Jobe RP, Ballantyne DL (1977) Inorganic implants. In: Converse JM (ed)Reconstructive plastic surgery, vol 1, 2nd edn. WB Saunders, Philadelphia, pp 393–412
Sato K, Fujino M, Kozuka T, Naito Y, Kitamura S, Nakano S, Ohyama C, Kawashima Y (1975) Transfemoral plug closure of patent ductus arteriosus.Circulation 51:337–341
Serbinenko FA (1974) Balloon catheterization and occlusion of major cerebral vessels.J Neurosurg 41:125–145
White RI, Kaufmann SL, Barth KH, Decaprio V, Strandbert JD (1979) Embolotherapy with detachable silicone balloons.Radiology 131:619–627
Williams DF, Roaf R (1973)Implants in surgery. WB Saunders, London, pp 229–230
Wolf KJ (1978) Therapeutische Embolisation von Organarterien: tierexperimentelle Untersuchungen, erste klinische Erfahrungen, Einführung eines neuen Embolisationsmaterials.Fortschr Rontgenstr 128:414–422
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Warnecke, I., Frank, J., Hohle, R. et al. Transvenous double-balloon occlusion of the persistent ductus arteriosus: An experimental study. Pediatr Cardiol 5, 79–83 (1984). https://doi.org/10.1007/BF02424955
Issue Date:
DOI: https://doi.org/10.1007/BF02424955