Summary
A new equation which describes the interdependence of instrument band spreading, injection volume and input profile is proposed and experimentally verified in two modes: 1. without a column; 2. with a column.
It is shown that under equivalent conditions both modes are in excellent agreement. The method of calculation of the variance of a response function appeared to be of utmost importance in correctly interpreting the experimentally observed interdependence of instrumental band spreading and injection characteristics.
Similar content being viewed by others
Abbreviations
- a0, a1, a2 :
-
Coefficients of the parabolic equation applied in the curve fitting of the data pairs
- b0, b1 :
-
Coefficients of the linear equation applied in the curve fitting of the data pairs
- D:
-
Factor depending on input profile and calculation method
- Dm :
-
Diffusion coefficient of a solute in the mobile phase
- Dp :
-
Average diffusion coefficient of a solute in a particle of the stationary phase
- dp :
-
Average particle diameter of the stationary phase
- F:
-
Volume flow rate
- k′:
-
Capacity factor
- M0 :
-
Zeroth moment
- M1 :
-
First normalized moment\(\int\limits_0^\infty {{{th(t)dt} \mathord{\left/ {\vphantom {{th(t)dt} {M_0 }}} \right. \kern-\nulldelimiterspace} {M_0 }}} \)
- M2 :
-
Second normalized central moment\(\int\limits_0^\infty {{{(t - M_1 )^2 h(t)dt} \mathord{\left/ {\vphantom {{(t - M_1 )^2 h(t)dt} {M_0 }}} \right. \kern-\nulldelimiterspace} {M_0 }}} \)
- Ncol :
-
Number of theoretical plates generated by the column
- r:
-
Regression coefficient of fitted curves
- \(\hat S_{yx}^{n - 2} \) :
-
Modified standard error of estimate for (n−2) degrees of freedom
- tR :
-
Retention time of eluted component
- u0 :
-
Linear velocity of an unretained component
- Vcol :
-
Column volume
- Vinj :
-
Volume of injected sample
- \(\bar y^{obs} \) :
-
Mean value of the dependent variable for different types of regression
- \(\sigma _{v(ext)}^2 \) :
-
Volume variance of concentration profile due to injection volume, injection device, tubing and detector (external broadening)
- \(\sigma _{v(inj)}^2 \) :
-
Volume variance of concentration profile due to injection volume
- \(\sigma _{v(col)}^2 \) :
-
Volume variance of the impulse response of the column
- \(\sigma _{v(0)}^2 \) :
-
Equal to\(\sigma _{v(ext)}^2 \) for Vinj→0, impulse response of the instrument
- \(\sigma _{v( )}^2 \) :
-
Time variances of above mentioned concentration profiles
- ∈t :
-
Total porosity of column bed
References
J. C. Sternberg, Advan. Chromatogr.2, 205 (1966).
I. Halàsz, P. Walking, J. Chromatogr. Sci.7, 129 (1969).
T. W. Smuts, D. J. Solms, F. A. Van Niekerk, V. Pretorius, J. Chromatogr. Sci.7, 24 (1969).
J. J. Kirkland, J. Chromatogr. Sci.7, 7 (1969).
J. F. K. Huber, J. A. J. Hulsman, C. A. M. Meyers J. Chromatogr.62, 79 (1971).
J. F. K. Huber, R. van der Linden, E. Ecker, M. Oreans, J. Chromatogr.83, 267 (1973).
B. L. Karger, M. Martin, G. Guiochon, Anal. Chem.46, 1640 (1974).
M. Martin, C. Eon, G. Guiochon, J. Chromatogr.108, 229 (1975).
A. Wehrli, K. Hermann, J. F. K. Huber, J. Chromatogr.125, 59 (1976).
J. J. Kirkland, W. W. Yau, H. J. Stoklosa, C. H. Dilks, Jr., J. Chromatogr. Sci.15, 303 (1977).
H. Colin, G. Guiochon, J. Chromatogr.158, 183 (1978).
H. Colin, M. Martin, G. Guiochon, J. Chromatogr.185, 79 (1979).
J. F. K. Huber, Instrumentation for HPLC,J. F. K. Huber, Ed., Elsevier, Amsterdam, 1978, p. 1.
J. F. K. Huber, personal communication, Institute of Analytical Chemistry, University of Vienna, 1977.
A. Wehrli, Z. Anal. Chem.277, 289 (1975).
B. Coq, G. Cretier, C. Gonnet, J. L. Rocca, Chromatographia11, 139 (1978).
B. Coq, G. Cretier, J. L. Rocca, J. Chromatogr.186, 457 (1979).
P. Roumeliotis, K. K. Unger, J. Chromatogr.185, 445 (1979).
W. Beck, I. Halàsz, Z. Anal. Chem.291, 340 (1978).
R. Endele, I. Halász, K. Unger, J. Chromatogr.99, 377 (1974).
K. P. Hupe, H. H. Lauer, to be published.
J. F. K. Huber, J. A. R. J. Hulsman, Anal. Chim. Acta38, 305 (1967).
J. F. K. Huber, J. Chromatogr. Sci. 7, 85 (1969).
J. F. K. Huber, Column Chromatography, E. Kováts, Ed., Chimia Supplementum, Sauerländer, Aarau, 1970, p. 24.
J. F. K. Huber, Ber. Bunsenges. Phys. Chem.77, 159 (1973).
A. B. Littlewood, Gas Chromatography, 2nd edn., Academic Press, 1970, p. 214.
L. R. Snyder, J. Chromatogr. Sci. 7, 352 (1969).
B. L. Karger, Modern Practice of Liquid Chromatography,J. J. Kirkland, Ed., Interscience, New York, 1971 Chapter 1.
Author information
Authors and Affiliations
Additional information
Presented as part of a poster at the Vth International Symposium on Column Liquid Chromatography, Avignon (France), 11–15 May 1981.
Rights and permissions
About this article
Cite this article
Lauer, H.H., Rozing, G.P. The selection of optimum conditions in HPLC I. The determination of external band spreading in LC instruments. Chromatographia 14, 641–647 (1981). https://doi.org/10.1007/BF02291104
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02291104