Skip to main content

Official Journal of the Japan Wood Research Society

  • Original Article
  • Published:

Development of LVL frame structures using glued metal plate joints II: strength properties and failure behavior under lateral loading

Abstract

In past years high priority was given to developing a seismic design for wood structures, including research on the response of wood structures to earthquakes. In this study a new type of portal frame with relatively large span was developed for the traditional Japanese wooden houses with large openings at the front to strengthen the structure. Stainless steel plates coated with zinc and glued with epoxy adhesives on laminated veneer lumber (LVL) members, composed of Douglas fir veneer and bonded with phenolformaldehyde resin, were used. The connection between the frame's beam and columns and between the columns and groundsills was mechanical, with bolts. The subject of this research was to analyze strength properties and failure behavior of glued LVL metal joints used as structural components and to evaluate the response of LVL portal frames under cyclic lateral loading. The results show that portal frames using glued LVL metal plates have a good multiplier for the shear walls and may be applied to traditional Japanese structures. The equivalent viscous damping provided good energy dissipation in the frames. The joints displayed good mechanical behavior during tests; moreover, the structures demonstrated high strength, stiffness, and ductility, which are necessary for a seismic design.

References

  1. Kataoka Y, Naito K. Ando H (1996) Re-Examination of Japanese traditional wooden frame structures. In: Proceedings of international wood engineering conference, New Orleans, pp 191–198

  2. Miyazawa K, Kohara K (1996) A study of wooden houses due to the 1995 Hyogo-Ken Nambu earthquake. In: Proceedings of international wood engineering conference. New Orleans, pp 339–346

  3. Pîrvu C, Yoshida H, Taki K (in press) Development of LVL frame structures using glued metal plates joints. I. Bond quality and joint performance of LVL-metal joints using epoxy resins. J Wood Sci 45:284–290

  4. Key Lam, LVL Manufacturing Company (1998) LVL for structural purposes, Brochure with technical data (in Japanese)

  5. Sano A, Pîrvu C, Yamada M, Taki K, Yoshida H (1999) Bondability of metal to wood joints. II. Improvement of the water resistance of epoxy resin in metal-wood joints (in Japanese). Mokuzai Gakkaishi 45:244–250

    CAS  Google Scholar 

  6. Yasumura M (1996) Evaluation of seismic performance of timber structures. In: Proceedings of international wood engineering conference, New Orleans, pp 45–52

  7. Housing Bureau, The Ministry of Construction (1990) The building standard law of Japan. Notification no. 1792. The Building Center of Japan, Tokyo, Japan

  8. Yasumura M (1993) Japan overview: design of timber joints in seismic zones. In: Proceedings of international workshop on wood connectors, Madison, WI, pp 42–51

    Google Scholar 

  9. Housing Bureau, The Ministry of Construction (1990) The building standard law of Japan. The Building Center of Japan, Tokyo, Japan

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hiroaki Yoshida.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pîrvu, C., Yoshida, H., Inayama, M. et al. Development of LVL frame structures using glued metal plate joints II: strength properties and failure behavior under lateral loading. J Wood Sci 46, 193–201 (2000). https://doi.org/10.1007/BF00776449

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00776449

Key words