Skip to main content
Log in

The effect of increasing gap width on localized densitometric changes within tibial ostectomies in a canine model

  • Laboratory Investigations
  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Abstract

Dual-energy X-ray absorptiometry (DXA) was used to quantitate the localized densitometric changes that occur early (0–16 weeks) in a tibial ostectomy model of three different gap widths in 15 dogs. Dogs were divided into three equal groups. A 5-mm (group 1), 15-mm (group 2), or 25-mm (group 3) unilateral tibial ostectomy was performed and stabilized with a unilateral external skeletal fixator in each dog. DXA of the gap tissue was performed at 0, 14, 30, 60, 90, and 120 days after surgery. Regions of interest (ROIs) included the entire gap (groups 1, 2, 3) and ROIs within the gap a defined distance from the proximal or distal cortical bone ends: 0–2.5 mm (groups 1, 2, 3); 2.5–5.0 mm (group 2, 3), 5.0–7.5 mm (groups 2, 3), 7.5–10.0 mm (group 3), and 10.0–12.5 mm (group 3). Bone mineral density (BMD) significantly changed over time in all three groups (P<0.0001). The BMD of the 5-mm gap increased over the 4-month study period and reached normal middiaphysial tibial BMD by 90 days after surgery. The BMD of the 15-mm gap also increased after surgery but reached a plateau at a BMD of ∼0.45 g/cm2 (48% of middiaphyseal BMD) at 60 days after surgery. The BMD of the 25-mm gap increased to a small extent during the first 30 days after surgery and then gradually decreased during the study period. Overall, the 5-mm gap had the highest BMD, followed by the 15-mm gap and the 25-mm gap (P<0.0001).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ammann P, Rizzoli R, Slosman D, Bonjour JP (1991) Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy x-ray absorptiometry. J Bone Miner Res 7: 311–316

    Google Scholar 

  2. Markel MD, Wikenheiser MA, Morin RL, Lewallen DG, Chao EYS (1991) The determination of bone fracture properties by dual-energy X-ray absorptiometry and single-phonton absorptiometry: a comparative study. Calcif Tissue Int 48:392–399

    Google Scholar 

  3. Mosheiff R, Klein BY, Leichter I, Chaimsky G, Nyska A, Peyser A, Segal D (1992) Use of dual-energy x-ray absorptiometry (DEXA) to follow mineral content changes in small ceramic implants in rats. Biomaterials 13:462–466

    Google Scholar 

  4. Ulivieri RM, Bossi E, Azzoni R, Ronzani C, Trevisan C, Montesano A, Ortolani S (1990) Quantification by dual photonabsorptiometry of local bone loss after fracture. Clin Orthop 250: 291–296

    Google Scholar 

  5. Cruess RL, Dumont J (1975) Current concepts. Fracture healing. Can J Surg 18:403–413

    Google Scholar 

  6. Frost HM (1989) The biology of fracture healing. An overview for clinicians. Part I. Clin Orthop 248:283–309

    Google Scholar 

  7. Hulth A (1989) Current concepts of fracture healing. Clin Orthop 249:265–284

    Google Scholar 

  8. Sevitt S (1980) Healing of fractures in man. In: Owen R, Goodfellow J, Bullough P (eds) Scientific foundations of orthopedics and traumatology. W.B. Saunders, Philadelphia, pp 258–272

    Google Scholar 

  9. Lewallen DG, Chao EYS, Kasman RA, Kelly PJ (1984) Comparison of the effects of compression plates and external fixators on early bone healing. J Bone Joint Surg 66-A:1084–1091

    Google Scholar 

  10. Markel MD, Wikenheiser MA, Chao EYS (1991) Formation of bone in tibial defects in a canine model. J Bone Joint Surg 73-A:914–923

    Google Scholar 

  11. Rand JA, An KN, Chao EYS, Kelly PJ (1981) A comparison of the effect of open intramedullary mailing and compression-plate fixation on fracture site blood flow and fracture union. J Bone Joint Surg 63-A:427–442

    Google Scholar 

  12. Rhinelander FW, Phillips RS, Steel WM, Beer JC (1968) Microangiography in bone healing. I. Displaced closed fractures. J Bone Joint Surg 50-A:643–662

    Google Scholar 

  13. Baron R, Vignery A, Neff L (1979) Processing of undecalcified bone specimens for bone histomorphometry. In: Recker RR (ed) Bone histomorphometry techniques and interpretation. CRC Press, Boca Raton, FL, pp 13–35

    Google Scholar 

  14. Hodgson SF (1986) Skeletal remodeling and renal osteodystrophy. Semin Nephrol 6:42–55

    Google Scholar 

  15. Markel MD, Wikenheiser MA, Chao EYS (1991) Formation of bone in tibial defects in a canine model. J Bone Joint Surg 73A:914–923

    Google Scholar 

  16. Jowsey J, Kelly PJ, Riggs BL (1965) Quantitative microradiographic studies of normal and osteoporotic bone. J Bone Joint Surg 47A:785–806

    Google Scholar 

  17. Kelly PJ, Peterson LFA, Janes JM (1959) A method of using sections for microangiography for subsequent histologic study. Proc Staff Meet Mayo Clin 34:274–283

    Google Scholar 

  18. Johnson J, Dawson-Hughes B (1991) Precision and stability of dual-energy X-ray absorptiometry measurements. Calcif Tissue Int 49:174–178

    Google Scholar 

  19. Kelly TL, Slovik DM, Neer RM (1989) Calibration and standardization of bone mineral densitometers. J Bone Miner Res 4:663–669

    Google Scholar 

  20. Markel MD, Gottsauner-Wolf F, Bogdanske JJ, Wahner HW, Chao EYS (1993) Dual energy x-ray absorptiometry of implanted femora after cemented and press-fit total hip arthroplasty in a canine model. J Orthop Res 11:452–456

    Google Scholar 

  21. Mazess R, Chesnut CH, McClung M, Genant H (1992) Enhanced precision with dual-energy x-ray absorptiometry. Calcif Tissue Int 51:14–17

    Google Scholar 

  22. Mazess RB, Trempe LA, Bisek JP, Hanson JA, Hans D (1991) Calibration of dual-energy x-ray absorptiometry for bone density. J Bone Miner Res 6:799–806

    Google Scholar 

  23. Rencken ML, Murano R, Drinkwater BL, Chesnut CH (1991) In vitro comparability of dual-energy X-ray absorptiometry (DEXA) bone densitometers. Calcif Tissue Int 48:245–248

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Markel, M.D., Bogdanske, J.J. The effect of increasing gap width on localized densitometric changes within tibial ostectomies in a canine model. Calcif Tissue Int 54, 155–159 (1994). https://doi.org/10.1007/BF00296067

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00296067

Key words

Navigation