Skip to main content
Log in

Use of the Cadzow procedure in 2D NMR for the reduction of t1 noise

  • Research Papers
  • Published:
Journal of Biomolecular NMR Aims and scope Submit manuscript

Summary

A data processing approach is proposed for reducing the t1 noise observed in multidimensional NMR spectra. This method is based on the use of the Cadzow procedure [Cadzow, J.A. (1988) IEEE Trans. Acous. Speech Signal Proc., 36, 49–62], and is demonstrated to be efficient for simulated cases as well as real experiments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • Barkhuijsen, H., DeBeer, R. and VanOrmondt, D. (1987) J. Magn. Reson., 73, 553–557.

    Google Scholar 

  • Bax, A., Griffey, R.H. and Hawkins, B.L. (1983) J. Magn. Reson., 55, 301–315.

    Google Scholar 

  • Bax, A. and Summers, M.F. (1986) J. Am. Chem. Soc., 108, 2093–2094.

    Google Scholar 

  • Brown, D.E. and Campbell, T.W. (1990) J. Magn. Reson., 89, 255–264.

    Google Scholar 

  • Cadzow, J.A. (1988) IEEE Trans. Acous. Speech Signal Proc., 36, 49–62.

    Google Scholar 

  • Delsuc, M.A. (1989) In Maximum Entropy and Bayesian Methods (Ed., Skilling, J.), Kluwer, Dordrecht, pp. 285–290.

    Google Scholar 

  • Diop, A., Briguet, A. and Graveron-Demilly, D. (1992) Magn. Reson. Med., 27, 318–328.

    Google Scholar 

  • Diop, A., Zaimwadghiri, Y., Briguet, A. and Graveron-Demilly, D. (1994) J. Magn. Reson. Ser. B, 105, 17–24.

    Google Scholar 

  • Dongarra, J.J., Bunch, J.R., Moler, C.B. and Stewart, G.W. (1979) LINPACK User's Guide, SIAM, Philadelphia, PA.

    Google Scholar 

  • Gibbs, A., Morris, G.A., Swanson, A.G. and Cowburn, D. (1993) J. Magn. Reson. Ser. A, 101, 351–356.

    Google Scholar 

  • Manoleras, N. and Norton, R.S. (1992) J. Biomol. NMR, 2, 485–494.

    Google Scholar 

  • Marshall, A.G. and Verdun, F.R. (1990) Fourier Transform in NMR, Optical, and Mass Spectroscopy. A User's Handbook, Elsevier, Amsterdam.

    Google Scholar 

  • Mehlkopf, A.F., Korbee, D. and Tiggelman, T.A. (1984) J. Magn. Reson., 58, 315–323.

    Google Scholar 

  • Mitshang, L., Cieslar, C., Holak, T.A. and Oschkinat, H. (1991) J. Magn. Reson., 92, 208–217.

    Google Scholar 

  • Nagayama, K., Bachman, P., Wüthrich, K. and Ernst, R.R. (1978) J. Magn. Reson., 31, 133–148.

    Google Scholar 

  • Press, W.H., Flannery, B.P., Teukolsky, S.A. and Vetterling, W.T. (1986) Numerical Recipes, Cambridge University Press, New York, NY.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brissac, C., Malliavin, T.E. & Delsuc, M.A. Use of the Cadzow procedure in 2D NMR for the reduction of t1 noise. J Biomol NMR 6, 361–365 (1995). https://doi.org/10.1007/BF00197635

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00197635

Keywords

Navigation