Abstract
Human corneas were preserved up to 40 days in a modified tissue culture medium at 31 °C. The corneal endothelium was examined by light microscopy before and after culture. After staining with trypan-blue the number of dead cells was counted and by swelling of the intercellular borders in a 1.8 per cent sucrose solution the cellular mosaic was observed. A loss of endothelial cells was found varying from 0–30 per cent. During culture the stroma increased considerably in thickness. Prior to transplantation the cornea was thinned during 24 h in culture medium containing 5 per cent Dextran T500. The combination of the organ culture procedure and the evaluation of the endothelium enables preservation of human corneas for at least 30 days. In addition the quality of the endothelium is guaranteed and the transport of corneas can be carried out at room temperature.
Similar content being viewed by others
References
Bigar F (1982) Specular microscopy of the corneal endothelium. Optical solutions and clinical results. Dev Ophthal 6:1–94
Doughman DJ, Van Horn D, Harris JE, Miller GE, Lindstrom R and Good RA (1974) The ultrastructure of human organ-cultured corneas. I. Endothelium. Arch Ophthal 92:516–523
Doughman DJ, Harris JE and Schmitt KM (1976) Penetrating keratoplasty using 37 °C organ-cultured cornea. Trans Amer Acad Ophthal Otokryng 81:778–793
Doughman DJ, Harris JE, Mindrup E and Lindstrom RL (1982) Prolonged donor cornea preservation in organ-culture: long term clinical evaluation. Cornea 1:7–20
Kirk AH and Hassard DTR (1969) Supravital staining of the corneal endothelium and evidence for a membrane on its surface. Canad J Ophthal 4:405–415
McCarey BE and Kaufman HE (1974) Improved corneal storage. Invest Ophthal 13:165–173
Sperling S (1978) Early morphological changes in organ-cultured human corneal endothelium. Acta Ophthal 56:785–792
Sperling S (1979) Human corneal endothelium in organ-culture. The influence of temperature and medium of incubation. Acta Ophthal 57:269–276
Sperling S and Gundersen HJG (1978) The precision of unbiased estimates of numerical density of endothelial cells in donor corneas. Acta Ophthal 56:793–802
Stocker FW, King EH, Lucas DO and Georgiade NA (1970) Clinical test for evaluating donor corneas. Arch Ophthal 84:2–7
Van der Want JJL, Pels E, Schuchard Y, Olesen B and Sperling S (1983) Electron microscopy of cultured human corneas. Osmotic hydration and the use of Dextran T500 in organ-culture. Arch Ophthal (in press)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pels, E., Schuchard, Y. Organ-culture preservation of human corneas. Doc Ophthalmol 56, 147–153 (1983). https://doi.org/10.1007/BF00154722