Abstract
This paper presents the results of two high-temperature tensile tests (steady-state tests and transient-state tests) of splice connections with high-strength bolts. First, steady-state tensile tests at high temperature were conducted to obtain the load-deformation behavior and tensile resistance of the connections. The tensile test results indicated that the ductility of connections increased when the steel temperature was over 500 °C. Second, transient-state tensile tests at constant load and increased temperature were conducted to investigate the influence of deformation rate on resistance. In the transient-state tests, the specimens were subjected to a constant load that was the maximum load from the steady-state test or from the calculated tensile resistance based on AIJ recommendations. In the ultimate stage under the transient state, the deformation rate for the connection considerably increased and contributed to improved resistance at elevated temperature. On the basis of these experimental results, this paper discusses the tensile resistance of splice connections with high-strength bolts exposed to fire.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Abbreviations
- A bs :
-
Cross-section area at the bolt shank (mm2)
- e :
-
End distance (mm)
- P u :
-
Tensile resistance of the splice connection (kN)
- P u1 :
-
Tensile resistance for the bolt in shear failure (kN)
- P u2 :
-
Tensile resistance for the tear-out failure (kN)
- t :
-
Main plate thickness (mm)
- σ bu :
-
Tensile strength of the bolt (N/mm2)
- σ u :
-
Tensile strength of the plate (N/mm2)
References
National Institute of Standards and Technology (2008) Final report on the Collapse of World Trade Center Building 7
Japanese Industrial Standards Committee (1998) Method of elevated temperature tensile test for steels and heat resisting-alloys, JIS G 0567
Architectural Institute of Japan (2008) Recommendation for fire resistant design of steel structures (in Japanese)
Kirby BR (1995) The behaviour of high-strength grade 8.8 bolts in fire. J Constr Steel Res 33:3–38
Sakumoto Y, Keira K, Furumura F, Ave T (1993) Tests of fire-resistant bolts and connections. J Struct Eng ASCE 119(11):3131–3150
Hirashima T, Hamada N, Ozaki F, Ave T, Uesugi H (2007) Experimental study on shear deformation behavior of high strength bolts at elevated temperature. J Struct Constr Eng Archit Inst Jpn (621):175–180 (in Japanese)
Hirashima T, Esaki Y, Ando S (2014) Load-deformation behaviour of bolted double-splice friction connections at elevated temperature. Paper presented at the 8th International Conference on Structures in Fire, Shanghai
Architectural Institute of Japan (2007) Japanese architectural standard specification, JASS 6 Steel Work. (in Japanese)
Ando S, Hirashima T (2015) Tensile resistance of friction type high strength bolted joints in fire. J Struct Constr Eng Archit Inst Jpn. (712):961–970 (In Japanese)
Architectural Institute of Japan (2006) Recommendation for design of connections in steel structures (in Japanese)
Acknowledgment
This work was supported by JSPS KAKENHI Grant Number 24560677.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Science+Business Media Singapore
About this paper
Cite this paper
Ando, S., Dwiputra, R., Hirashima, T. (2017). Tensile Resistance of Splice Connections with High-Strength Bolts in Fire. In: Harada, K., Matsuyama, K., Himoto, K., Nakamura, Y., Wakatsuki, K. (eds) Fire Science and Technology 2015. Springer, Singapore. https://doi.org/10.1007/978-981-10-0376-9_32
Download citation
DOI: https://doi.org/10.1007/978-981-10-0376-9_32
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-0375-2
Online ISBN: 978-981-10-0376-9
eBook Packages: EngineeringEngineering (R0)