Figure 1 is showing the gravimetric measurement system Topas GMS 141. The system is used to measure the condensate and oil concentration (oil carryover) in the full blow by stream of combustion engines. The quantity of the fluid blow by fraction is measured by the determination of the mass of a filter paper. The oil emission is determined in a steady state condition of the engine.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Fachmedien Wiesbaden GmbH
About this paper
Cite this paper
Ruppel, S., Schatz, D., Wöhler, M., Elsäßer, A. (2017). Optimization of oil mist separation within the complete crankcase ventilation system. In: Siebenpfeiffer, W. (eds) Heavy-Duty-, On- und Off-Highway-Motoren 2016. Proceedings. Springer Vieweg, Wiesbaden. https://doi.org/10.1007/978-3-658-19012-5_14