Skip to main content

Regional Analysis of Left Ventricle Function Using a Cardiac-Specific Polyaffine Motion Model

  • Conference paper
Book cover Functional Imaging and Modeling of the Heart (FIMH 2013)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 7945))

Abstract

Given the complex dynamics of cardiac motion, understanding the motion for both normal and pathological cases can aid in understanding how different pathological conditions effect, and are affected by cardiac motion. Naturally, different regions of the left ventricle of the heart move in different ways depending on the location, with significantly different dynamics between the septal and free wall, and basal and apical regions. Therefore, studying the motion at a regional level can provide further information towards identifying abnormal regions for example. The 4D left ventricular motion of a given case was characterised by a low number of parameters at a region level using a cardiac specific polyaffine motion model. The motion was then studied at a regional level by analysing the computed affine transformation matrix of each region. This was used to examine the regional evolution of normal and pathological subjects over the cardiac cycle. The method was tested on 15 healthy volunteers with 4D ground truth landmarks and 5 pathological patients, all candidates for Cardiac Resynchronisation Therapy. Visually significant differences between normal and pathological subjects in terms of synchrony between the regions were obtained, which enables us to distinguish between healthy and unhealthy subjects. The results indicate that the method may be promising for analysing cardiac function.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Tobon-Gomez, C., Craene, M.D., McLeod, K., Lautz, T., Shi, W., Hennemuth, A., Prakosa, A., Wang, H., Carr-White, G., Kapetanakis, S., Lutz, A., Rasche, V., Schaeffter, T., Butakoff, C., Friman, O., Mansi, T., Sermesant, M., Zhuang, X., Ourselin, S., Peitgen, H.O., Pennec, X., Razavi, R., Reuckert, D., Frangi, A.F., Rhode, K.S.: Benchmarking framework for myocardial tracking and deformation algorithms: An open access database. Med. Im. Anal (2013)

    Google Scholar 

  2. Wang, H., Amini, A.: Cardiac motion and deformation recovery from MRI: a review. IEEE Trans. Med. Imag. 31(2) (2012)

    Google Scholar 

  3. McLeod, K., Seiler, C., Sermesant, M., Pennec, X.: A near-incompressible poly-affine motion model for cardiac function analysis. In: Camara, O., Mansi, T., Pop, M., Rhode, K., Sermesant, M., Young, A. (eds.) STACOM 2012. LNCS, vol. 7746, pp. 288–297. Springer, Heidelberg (2013)

    Chapter  Google Scholar 

  4. Seiler, C., Pennec, X., Reyes, M.: Capturing the multiscale anatomical shape variability with polyaffine transformation trees. Med. Im. Anal (2012)

    Google Scholar 

  5. Arsigny, V., Commowick, O., Ayache, N., Pennec, X.: A fast and log-euclidean polyaffine framework for locally linear registration. J. Math. Im. and Vision 33(2) (2009)

    Google Scholar 

  6. Toussaint, N., Sermesant, M., Stoeck, C.T., Kozerke, S., Batchelor, P.G.: In vivo human 3D cardiac fibre architecture: Reconstruction using curvilinear interpolation of diffusion tensor images. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010, Part I. LNCS, vol. 6361, pp. 418–425. Springer, Heidelberg (2010)

    Google Scholar 

  7. Cerqueira, M., Weissman, N., Dilsizian, V., Jacobs, A., Kaul, S., Laskey, W., Pennell, D., Rumberger, J., Ryan, T., Verani, M.: Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. Circulation 105 (2002)

    Google Scholar 

  8. Commowick, O., Arsigny, V., Isambert, A., Costa, J., Dhermain, F., Bidault, F., Bondiau, P.Y., Ayache, N., Malandain, G.: An efficient locally affine framework for the smooth registration of anatomical structures. Med. Im. Anal. 12(4) (2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

McLeod, K., Seiler, C., Toussaint, N., Sermesant, M., Pennec, X. (2013). Regional Analysis of Left Ventricle Function Using a Cardiac-Specific Polyaffine Motion Model. In: Ourselin, S., Rueckert, D., Smith, N. (eds) Functional Imaging and Modeling of the Heart. FIMH 2013. Lecture Notes in Computer Science, vol 7945. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-38899-6_57

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-38899-6_57

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-38898-9

  • Online ISBN: 978-3-642-38899-6

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics