The Influence of Patient Miscentering on Patient Dose and Image Noise in Two Commercial ct Scanners

  • Conference paper
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010

Part of the book series: IFMBE Proceedings ((IFMBE,volume 29))

  • 159 Accesses

Abstract

The clinical influences of patient miscentering on patient dose and image noise were investigated for two models of commercial CT scanners. Several phantoms were scanned on 4-slice GE Lightspeed and 64-slice GE Lightspeed VCT. Regression models of surface dose and image noise were generated as a function of phantom size and the value of miscentering. 64 scout images of patients from the first scanner and 113 from the second one were analyzed to assess the possible amount of increasing in dose and noise. For the first scanner the average amount of miscentering was 3 cm below the isocenter which leads to 25.8% increase in dose and 8.3% increase in noise. These values for the second scanner were 1.6 cm below the center, 19.8% and 6.2%, respectively. The results clearly demonstrate that patient miscentering may substantially increase dose and image noise. Therefore, technologists are strongly encouraged to pay greater attention to patient centering.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 349.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 449.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Habibzadeh, M.A., Ay, M.R., asl, A.R.K., Ghadiri, H., Zaidi, H. (2010). The Influence of Patient Miscentering on Patient Dose and Image Noise in Two Commercial ct Scanners. In: Bamidis, P.D., Pallikarakis, N. (eds) XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010. IFMBE Proceedings, vol 29. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13039-7_82

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-13039-7_82

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-13038-0

  • Online ISBN: 978-3-642-13039-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics