Abstract

Due to the unattended design screening of sleep-disordered breathing (SDB) has a significant error rate. Possible reasons for the screening failure are off-centered or unfixed sensors. Therefore often another screening is mandatory which is both expensive and impeding for the patient. In order to minimise screening failure it is desirable to develop contactless screening devices. In 7 patients with a total of 477 central apneas we studied the diagnostic accuracy of Sleep-Minder (Biancamed, Dublin, Ireland) that was placed approx. 1m from the patient. Sleep-Minder emitted a very weak radio wave (factor 10-100 less compared to common household devices) and detected thorax and abdomen movement by measuring the Doppler effect. SleepMinder could detect 431 central apneas. This study showed the utility of SleepMinder, a contactless screening device, for detecting central apneas. Thus, SleepMinder can be used as an unattended screening method minimising screening failure.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Weinreich, G., de Chazal, P., Wang, Y., Teschler, S., Teschler, H. (2009). A Pilot Study on Non-contacting Detection of Central Apneas. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/7. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03885-3_219

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03885-3_219

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03884-6

  • Online ISBN: 978-3-642-03885-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics