Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/1))

  • 109 Accesses

Abstract

A common approach to IMRT pre-treatment quality assurance is to capture images of IMRT fields with no patient or phantom in the beam, and compare these to images predicted by the treatment planning system. This is done prior to treatment in order to detect and correct file transfer and beam delivery errors that would affect the quality of treatment. In many institutions, the distance between measured and predicted images is quantified using gamma indices with 3%/3mm criteria. This work: (i) examines repeated electronic portal imaging device (EPID) images of an IMRT field; (ii) evaluates output variations, alignment errors and measurement ‘noise’; and (iii) uses this data with receiver operating curve (ROC) analysis to determine the size of IMRT delivery errors that can be reliably detected. The gamma index with 3%/3mm acceptance criteria is shown to be sub-optimal; dose differences must be ≥5% in a 24mm×24mm area to be detected 95% of the time, while a pixel intensity difference (PID) test reliably detects ≥2% dose deviations in the same area. Excluding high gradient regions has little effect on the detection ability of gamma, but allows a PID test to detect 2% dose deviations in 5mm×5mm areas.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Gordon, J.J., Gardner, J., Wang, S., Siebers, J.V. (2009). Analysis of Error Detection in EPID-Based IMRT Pre-Treatment QA. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03474-9_145

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03474-9_145

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03472-5

  • Online ISBN: 978-3-642-03474-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics