Quantifying Blood-Oxygen Saturation Measurement Error in Motion Contaminated Pulse Oximetry Signals

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada

Part of the book series: IFMBE Proceedings ((IFMBE,volume 51))

Abstract

Oxygen saturation measurements from pulse oximetry (SpO 2 ) can be unreliable in the presence of motion artifacts. While pulse oximetry is a crucial measurement in controlled environments, such as surgery or intensive care, its vulnerability to motion artifacts has slowed its adoption in wearable continuous monitoring devices. Measurement error can cause errors or delays in clinical decision-making. In re- mote monitoring applications, pulse oximeters should report measurement confidence along with SpO 2 to help clinicians make decisions about the validity of alarm conditions. This paper seeks to relate signal quality to SpO 2 measurement confidence. In this study, clean photoplethysmograph (PPG) signals were collected from a pulse oximeter and contaminated with motion artifact. A range of linear combinations of signal and artifact were generated and SpO 2 measurements were calcu- lated. Since true SpO 2 remained constant, measurement varia- tion was caused solely by signal contamination. Unacceptably high measurement error was found below the 15-20 dB signal to noise ratio (SNR) range. Two models based on Additive White Gaussian Noise (AWGN) were evaluated for their similarity to the motion artifact data. The first had identical noise on both red and infrared PPG signals; the second has uncorrelated noise. Both models successfully predicted negative measurement bias at low SNR, but only the second predicted the observed meas- urement variance.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Clarke, G.W.J., Chan, A.D.C., Adler, A. (2015). Quantifying Blood-Oxygen Saturation Measurement Error in Motion Contaminated Pulse Oximetry Signals. In: Jaffray, D. (eds) World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada. IFMBE Proceedings, vol 51. Springer, Cham. https://doi.org/10.1007/978-3-319-19387-8_240

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-19387-8_240

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-19386-1

  • Online ISBN: 978-3-319-19387-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics