Skip to main content

Fully-Automated “Timed Up and Go” and “30-Second Chair Stand” Tests Assessment: A Low Cost Approach Based on Arduino and LabVIEW

  • Conference paper
CONTROLO’2014 – Proceedings of the 11th Portuguese Conference on Automatic Control

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 321))

  • 3753 Accesses

Abstract

In this paper it is described the prototyping of an instrumented chair that allows to fully-automate the “Timed Up and Go” and “30-Second Chair Stand” tests assessment. The presented functional chair prototype is a low cost approach that uses inexpensive sensors and the Arduino platform as the data acquisition board, with its software developed resorting to LabVIEW. The “Timed up and go test” consists in measuring the time spent in the task execution of standing up from a chair, walk three meters with a maximum speed without running, turn a cone and going back to the initial position. The “30-Second Chair Stand” test consists in the count of the number of completed chair stands in 30 seconds. It are agility and strength tests easy to setup and execute although they lack of repeatability, whenever the measures are taken manually, due to the rough errors that are introduced.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bohannon, R.W.: Reference values for the Timed Up and Go Test: A Descriptive Meta-Analysis Journal of Geriatric Physical Therapy (2006)

    Google Scholar 

  2. Millor, N., Lecumberri, P., Gmez, M., Martnez-Ramrez, A., Izquierdo, M.: An evaluation of the 30-s chair stand test in older adults: frailty detection based on kinematic parameters from a single inertial unit. International Journal of NeuroEngineering and Rehabilitation (2013)

    Google Scholar 

  3. Frenken, T., Vester, B., Brell, M., Hein, A.: ATUG: Fully-automated timed up and go assessment using ambient sensor technologies. In: 5th International Conference on Pervasive Computing Technologies for Healthcare 2011 (2011)

    Google Scholar 

  4. Mohammad, T.: Using Ultrasonic and Infrared Sensors for Distance Measurement World Academy Of Science. Engineering and Technology (2009)

    Google Scholar 

  5. Malheiros, P., Gonçalves, J., Costa, P.: Towards a more accurate model for an infrared distance sensor. In: International Symposium on Computational Intelligence for Engineering Systems, 18-19 November 2009. ISEP-Porto, Portugal (2009)

    Google Scholar 

  6. National Instruments NI LabVIEW Interface for Arduino Toolkit (October 2013), http://sine.ni.com/nips/cds/view/p/lang/pt/nid/209835

  7. Betânia Foundation (2013), http://www.fundacaobetania.com

  8. Thompson, M., Medley, A.: Performance of Individuals with Parkinson’s Disease on the Timed Up & Go Journal of Neurologic Physical Therapy (2009)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to José Gonçalves .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Gonçalves, J., Batista, J., Novo, A. (2015). Fully-Automated “Timed Up and Go” and “30-Second Chair Stand” Tests Assessment: A Low Cost Approach Based on Arduino and LabVIEW. In: Moreira, A., Matos, A., Veiga, G. (eds) CONTROLO’2014 – Proceedings of the 11th Portuguese Conference on Automatic Control. Lecture Notes in Electrical Engineering, vol 321. Springer, Cham. https://doi.org/10.1007/978-3-319-10380-8_64

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-10380-8_64

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-10379-2

  • Online ISBN: 978-3-319-10380-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics