Abstract
Lung nodule progression assessment from medical imaging is a critical biomarker for assessing the course of the disease or the patient’s response to therapy. CT images are routinely used to identify the location and size and rack the progression of lung nodules. However, nodule segmentation is challenging and prone to error, due to the irregular nodule boundaries, therefore introducing error in the lung nodule quantification process. Here, we describe the development and evaluation of a feature-based affine image registration framework that enables us to register two time point thoracic CT images as a means to account for the back-ground lung tissue deformation, then use digital subtraction images to assess tumor progression/regression. We have demonstrated this method on twelve de-identified patient datasets and showed that the proposed method yielded a better than 1.5 mm registration accuracy vis-à-vis the widely accepted non-rigid image registration techniques. To demonstrate the potential clinical value of our described technique, we conducted a study in which our collaborating clinician was asked to provide an assessment of nodule progression/regression using the digital subtraction images post-registration. This assessment was consistent, yet provided more confidence, than the traditional lung nodule tracking based on visual analysis of the CT images.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Fischbach, F., Knollmann, F., Griesshaber, V., Freund, T., Akkol, E., Felix, R.: Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur. Radiol. 13, 2378–2383 (2003)
Hansell, D.M., Bankier, A., MacMahon, H., McLoud, T.C., Müller, N.L., Remy, J.: Fleischner society: glossary of terms for thoracic imaging. Radiology 246(3), 697–722 (2008)
Henschke, C.I., McCauley, D.I., Yankelevitz, D.F., Naidich, D.P., McGuinness, G., Miettinen, O.S., Libby, D.M., Pasmantier, M.W., Koizumi, J., Altorki, N.K., Smith, J.P.: Early lung cancer action project: overall design and findings from baseline screening. Lancet 354, 99–105 (1999)
Kakinuma, R., Ashizawa, K., Kuriyama, K., Fukushima, A., Ishikawa, H., Kamiya, H., Koizumi, N., Maruyama, Y., Minami, K., Nitta, N., Oda, S., Oshiro, Y., Kusumoto, M., Murayama, S., Murata, K., Muramatsu, Y., Moriyama, N.: Measurement of focal ground-glass opacity diameters on CT images. Interobserver agreement in regard to identifying increases in the size of ground-glass opacities. Acad. Radiol. 19, 389–394 (2012)
Kim, H., Park, C.M., Lee, S.M., Lee, H.J.: Measurement variability of volume and mass in nodules with a solid portion less than or equal to 5 mm. Radiology 269, 585–593 (2013)
Ko, J.P., Berman, E.J., Kaur, M., Babb, J.S., Bomsztyk, E., Greenberg, A.K., Naidich, D.P., Rusinek, H.: Pulmonary nodules: growth rate assessment in patients by using serial CT and three-dimensional volumetry. Radiology 262, 662–671 (2012)
Maurer, C.R., Qi, R., Raghavan, V.: A linear time algorithm for computing exact euclidean distance transforms of binary images in arbitrary dimensions. IEEE Transact. Pattern Anal. Mach. Intell. 25(2), 265–270 (2003)
Oliveira, F.P.M., Tavares, J.M.R.S.: Medical image registration: a review. Comput. Methods Biomech. Biomed. Eng. Imaging Vis. 17, 73–93 (2014)
Rajpoot, K., Grau, V., Noble, J.A.: Local-phase based 3-D boundary detection using MONOGENIC signal and its application to real-time 3-D echocardiography images. In: Proceedings of IEEE International Symposium on Biomedical Imaging: From Nano to Macro 2009, pp. 783–786 (2009)
Song, G., Tustison, N., Avants, B., Gee, J.C.: Lung CT image registration using diffeomorphic transformation models. In: Medical Image Analysis for the Clinic: A Grand Challenge, pp. 23–32 (2010)
Staring, M., Pluim, J.P.W., de Hoop, B., Klein, S., van Ginneken, B., Gietema, H., Nossent, G., Schaefer-Prokop, C., van de Vorst, S., Prokop, M.: Image subtraction facilitates assessment of volume and density change in ground-glass opacities in chest CT. Invest. Radiol. 44, 61–66 (2009)
Viergever, M.A., Maintz, J.B., Klein, S., Murphy, K., Staring, M., Pluim, J.P.W.: A survey of medical image registration – under review. Med. Image Anal. 33, 140–144 (2016)
Zheng, Y., Kambhamettu, C., Bauer, T., Steiner, K.: Accurate estimation of pulmonary nodule’s growth rate in CT images with nonrigid registration and precise nodule detection and segmentation. In: 2009 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops, pp. 101–108. IEEE (2009)
Acknowledgements
Research reported in this publication was supported by the National Institute of General Medical Sciences of the National Institutes of Health under Award No. R35GM128877 and by the Office of Advanced Cyber infrastructure of the National Science Foundation under Award No. 1808530.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Zikri, Y.K.B., Helguera, M., Cahill, N.D., Shrier, D., Linte, C.A. (2019). Toward an Affine Feature-Based Registration Method for Ground Glass Lung Nodule Tracking. In: Tavares, J., Natal Jorge, R. (eds) VipIMAGE 2019. VipIMAGE 2019. Lecture Notes in Computational Vision and Biomechanics, vol 34. Springer, Cham. https://doi.org/10.1007/978-3-030-32040-9_26
Download citation
DOI: https://doi.org/10.1007/978-3-030-32040-9_26
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-32039-3
Online ISBN: 978-3-030-32040-9
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)